  1. Replies
    4
    Views
    452

    I did some work for a lady up the road who used...

    I did some work for a lady up the road who used to have a store. She said they bought it for the store and never got it installed. Her husband died a few years ago and shes been cleaning out the...
  2. Replies
    4
    Views
    452

    http://www.ebay.com/itm/151366532362?ssPageName=ST...

    http://www.ebay.com/itm/151366532362?ssPageName=STRK:MESELX:IT&_trksid=p3984.m1555.l2649
  3. Replies
    4
    Views
    452

    Vintage Singer central A/C

    1979 Singer 2.5 ton central air conditioning system including condenser, evaporator, and line set. This is N.O.S. and has never been installed. Condenser, evaporator, and lines are all factory sealed...
  4. Replies
    11
    Views
    851

    Inside temp? TXV or piston/cap tube? Adding...

    Inside temp? TXV or piston/cap tube? Adding refrigerant would lower super heat. If its a package unit you could weigh in the charge.
  5. Replies
    14
    Views
    1,345

    Sounds like low charge. 150 is not high, its low.

    Sounds like low charge. 150 is not high, its low.
  6. Replies
    11
    Views
    823

    Thanx guys for all your help and input. I will be...

    Thanx guys for all your help and input. I will be leaving it as is. I thought all was well but had an odd feeling about those pressures.
  7. Replies
    11
    Views
    823

    Took some refrigerant out to see what would...

    Took some refrigerant out to see what would happen, had subcooling down to 3-4 degrees, very little if any change in condition. Put it back in.
  8. Replies
    11
    Views
    823

    Did not measure air flow at all registers but...

    Did not measure air flow at all registers but with hotwire its around 900. If the air flow was to high I would expect a much lower tempature drop, and if air flow to low I would expect a much lower ...
  9. Replies
    11
    Views
    823

    Rheem A/C confusion

    I looked at a Rheem A/C earlier today and I am a bit confused. Model 13aja24a01, 2 ton, R-22, 5 years old, 2 ton "N" cased coil with txv on Rheem 60,000 btu furnace. Outdoor temp.- 76*, indoor temp.-...
  10. Thread: Aaon units

    by joeblo
    Replies
    18
    Views
    2,488

    I am really pleased with Orion tech support, the...

    I am really pleased with Orion tech support, the Aaon units them selves, not so much.
  11. Replies
    7
    Views
    1,452

    Is the furnace dirty and sucking in a lot of...

    Is the furnace dirty and sucking in a lot of dust? Is there something in the air that could be burning to it? What are you using to clean it with? Don't use sand paper. I just use a small wire brush.
  12. Replies
    17
    Views
    2,830

    I called honeywell last week and ask the same...

    I called honeywell last week and ask the same question. In short the answer is no. The t'stat adapts to differing conditions such as run time, cycles, and tempatures. The same thermostat hooked to...
  13. Replies
    17
    Views
    2,145

    The more often it is cleaned the less time and...

    The more often it is cleaned the less time and work to clean it. I have seen some that were so bad that they could not be cleaned with out complete disasembly.
  14. Thread: wifi thermostat

    by joeblo
    Replies
    21
    Views
    2,968

    Just installed a Honeywell vision Pro a couple of...

    Just installed a Honeywell vision Pro a couple of weeks ago. Easy to use and set up, home owner loves it. I believe it only cost me about $30 more than the standard touch screen.
  15. Replies
    33
    Views
    3,294

    Thats what I was thinking. Maybe the check valve...

    Thats what I was thinking. Maybe the check valve to the air coil is stuck. If the charge is right, coil is clean and good air flow THROUGH coil,(make sure air is not bypassing coil some how),thats...
  16. Replies
    22
    Views
    2,703

    Check the burner orifices to see if they are...

    Check the burner orifices to see if they are plugged. I've seen them plugged with bugs and spider webs. Also check gas pressure in and out of valve.
  17. Thread: Rheem heat pump

    by joeblo
    Replies
    7
    Views
    1,860

    Could be outdoor t'stat issue as well.

    Could be outdoor t'stat issue as well.
  18. Replies
    15
    Views
    1,250

    Longer run times equals less cycling and fewer...

    Longer run times equals less cycling and fewer brake downs, more even temps, and the difference in efficiency would be very minor.
  19. Replies
    27
    Views
    3,439

    I never heard of it either. I always supply my...

    I never heard of it either. I always supply my own refrig. and use what the manufacture recommends. I would tell him if he wants it charged with that, then he can do it.
  20. Replies
    14
    Views
    1,440

    Oil furns put out hotter air, but lower temp air...

    Oil furns put out hotter air, but lower temp air and longer run times produce a more comfortable house. You will have a hard time convincing people of that if they have always used oil.
  21. Replies
    15
    Views
    1,250

    Best is to offer all the pros and cons and let...

    Best is to offer all the pros and cons and let the customer decide. In my house I would use 2 stage stat.
  22. Replies
    22
    Views
    3,013

    Check the vacuum to the switch, maybe the line is...

    Check the vacuum to the switch, maybe the line is plugged up or there is water in furnace due to a plugged drain.
  23. Replies
    8
    Views
    928

    I think he is currently taking a test.

    I think he is currently taking a test.
  24. http://www.trane.com/CPS/Uploads/UserFiles/Control...

    http://www.trane.com/CPS/Uploads/UserFiles/Controls/BAS-SVX36C-EN_03132012.pdf See if this works
  25. You can get it on tranes website. There are a few...

    You can get it on tranes website. There are a few that look like that so a part number would be helpful. They call it a display tempature sensor.
  26. Replies
    18
    Views
    3,242

    The toughest problems are the ones somebody else...

    The toughest problems are the ones somebody else created.
  27. Replies
    20
    Views
    2,838

    R-22 is not a mixed refrigerant. Subcooling is...

    R-22 is not a mixed refrigerant. Subcooling is the cooling after in has become 100% liquid (no bubbles). I would check to make sure your readings are correct and possibly a restriction before the...
  28. Replies
    3
    Views
    820

    My quess is there is a failure with the local set...

    My quess is there is a failure with the local set point. Just kidding, you may want to post this in the controls section.
  29. Replies
    10
    Views
    1,124

    Moisture creates acid in system.Suction line...

    Moisture creates acid in system.Suction line driers should be temporary and can create more problems if left in. A drier does not replace a proper evacuation, it does not remove noncondensables. I...
  30. Replies
    2
    Views
    1,432

    My only warranty claim with Ridgid was a broken...

    My only warranty claim with Ridgid was a broken head on my seesnake. I took it back to the distributor and was given a replacement, no questions or paper work.
  31. Replies
    10
    Views
    2,059

    It is a must have tool, I personally will not buy...

    It is a must have tool, I personally will not buy anything but an H10 but thats just me. Some places you can't see or get to with soap bubbles.
  32. Replies
    43
    Views
    5,513

    I buy 2 or 3 cheap meters at a time, they are...

    I buy 2 or 3 cheap meters at a time, they are always getting used, dropped,wet, etc..., having a spare is a must. I am currently using a $50 craftsman and have no problems with it. Astime goes on you...
  33. Replies
    15
    Views
    1,977

    If you jumper R to G and the fan switch on the...

    If you jumper R to G and the fan switch on the thermostat is in the auto position the A/C cond will come on, this is normal. Disconnect the Y when doing this. The relay on the circuit board that...
  34. Replies
    35
    Views
    3,469

    Check TXV in outdoor unit or check valve on...

    Check TXV in outdoor unit or check valve on indoor unit, hard to tell with out putting on gauges.If you have a high pressure going to the indoor unit and a low pressure coming back on the liquid line...
  35. 330951330961330971 These are the only pics I...

    330951330961330971

    These are the only pics I could find, I have done suction and discharge lines the same way. (This is a Aquasnap). I think this was about 2 years ago, checked it last month and...
  36. I have done this a few times with no problems,...

    I have done this a few times with no problems, clean well, oxy/ace, and 56% braze rod. Use a hot flame to do it quickly and pre heat the discharge line a few inches away from compressor. And don't...
  37. You are correct about the aux. heat coming on and...

    You are correct about the aux. heat coming on and making the air warmer. It sounds like you have a problem with your heat pump and should have it looked at by a professional. If the heat pump is not...
  38. Thread: Christmas bonus

    by joeblo
    Replies
    35
    Views
    6,610

    We get a weeks pay

    We get a weeks pay
  39. Thread: New guy in PA

    by joeblo
    Replies
    13
    Views
    2,644

    Well the phone just rang, time to go back to...

    Well the phone just rang, time to go back to work. (will it ever end), talk to you guys later.
  40. Replies
    1
    Views
    1,415

    Wow just two weeks? What did you do to him? What...

    Wow just two weeks? What did you do to him? What would you like to know?
  41. Thread: New guy in PA

    by joeblo
    Replies
    13
    Views
    2,644

    Can't put my finger on it, I just don't get...

    Can't put my finger on it, I just don't get excited when I have to go there. Think maybe I have just had my fill of grocery stores.
  42. Thread: New guy in PA

    by joeblo
    Replies
    13
    Views
    2,644

    I do some rack systems, you can have them. Used...

    I do some rack systems, you can have them. Used to do alot of them years ago and thought I was done.
  43. Thread: New guy in PA

    by joeblo
    Replies
    13
    Views
    2,644

    No, Tudi mech., I do alot of work in Lawrence...

    No, Tudi mech., I do alot of work in Lawrence county. Small world.
  44. Thread: New guy in PA

    by joeblo
    Replies
    13
    Views
    2,644

    Not to far from you, in evans city.

    Not to far from you, in evans city.
  45. Replies
    3
    Views
    907

    I thought I would start out by helping those who...

    I thought I would start out by helping those who might need work, did not think that was a bad thing.
  46. Replies
    3
    Views
    907

    Job openings in Pitts., Pa

    To post HELP WANTED you must be a Professional Member of this site.
  47. Thread: New guy in PA

    by joeblo
    Replies
    13
    Views
    2,644

    New guy in PA

    Hello, I have been using this site for years for info and thought I should join. Many of you have helped me in the past and did not know it, to you I say thank you. I have been doing Residential,...