Search:

Type: Posts; User: BadBozo2315

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    8
    Views
    344

    You don't even have to kill the breaker. Power...

    You don't even have to kill the breaker. Power is supplied via the cat 5 network cable going in to the computer. Pull that cable, pull the battery, give it just a few seconds, and replace them,...
  2. Replies
    7
    Views
    379

    >I'll take the vct series back. Yup. How...

    >I'll take the vct series back.

    Yup. How about those gawd awful pop-down Prince Castle toasters? The first time I opend the control side of one I'm like, oh hell no. :)
  3. Anyone rolling out the new ChickFilA Garland grill?

    Having any (more) problems with them than I am? :)
  4. Replies
    7
    Views
    379

    The UTX I'm working on at a McDee's has the...

    The UTX I'm working on at a McDee's has the drive-side bearing of the horizontal conveyor locking up. Complains about checking drive system and refuses to run. Squirted some White Lithium grease...
  5. >so your thinking the test strip the health...

    >so your thinking the test strip the health inspector puts in there may not be getting hit with enough water?

    Well, I'm having trouble coming up with a senario that includes perfectly hot water,...
  6. Are you sure that there is enough water flowing...

    Are you sure that there is enough water flowing out to the rinse arms?

    In other words the pressure could be fine, but all but 2 of the rinse nozzles are open.

    I'd maybe jump the door switch,...
  7. Replies
    15
    Views
    652

    You have to understand, to do their job...

    You have to understand, to do their job correctly, they have to find *something* wrong. There is never a commercial kitchen that is 100 percent by-the-book. It was explained to me when I worked in...
  8. Replies
    3
    Views
    429

    Hey! Who let in someone who knows something? Did...

    Hey! Who let in someone who knows something? Did an engineer type slip in?

    And no one told me there'd be math here. It makes the head hurt.

    Most of us grunts here just fix things. :)
  9. Replies
    17
    Views
    846

    > I appologize to badbozo for not making it clear...

    > I appologize to badbozo for not making it clear that this was a gas unit.

    After I posted my last scribe, I had the prototypical DUH moment- I saw the title of the thread as a HY3 G. In any...
  10. Replies
    17
    Views
    846

    Let's be clear on how-it-works. The bottom probe...

    Let's be clear on how-it-works. The bottom probe is the low-level-cutout, ie the heater/burner safety probe. The top probe is the high-water-level, ie water at stop fill level. So to troubleshoot...
  11. Replies
    15
    Views
    781

    I've always carried 2 aligator clip wires in my...

    I've always carried 2 aligator clip wires in my tool bag. I'd just clip them onto the valve at the appropriate terminals *that go to the pilot coil* and hold the other ends with my fingers. You're...
  12. Replies
    17
    Views
    846

    [Monty Python voice] Blackberry?!?? Smart...

    [Monty Python voice] Blackberry?!?? Smart phone?!?!?? Souch Luuxsury!

    Cripes, we still have friggin flip phones, no email, no texting, no tethering. However, they have recently set us up with...
  13. Replies
    17
    Views
    846

    >Unfortunately, at some point I'd left my...

    >Unfortunately, at some point I'd left my HyperSteam manual on top of somebody's steamer I was troubleshooting.

    Quick quiz o' the day: How many of us use paper manuals these days?

    I only have...
  14. Replies
    15
    Views
    781

    You didn't hear this from me, but disconnect all...

    You didn't hear this from me, but disconnect all wiring from the gas valve.
    Get yourself a AA battery and briefly connect it up to the pilot safety solenoid and push in on the knob in the pilot...
  15. Replies
    17
    Views
    846

    http://www.unifiedbrands.net/assets/docs/groen/Ret...

    http://www.unifiedbrands.net/assets/docs/groen/Ret_HY_OM_6G.pdf

    May not be the exact manual, but it's close enough. The controller is the same I believe.

    Yeah, sounds like a board issue, or...
  16. Replies
    17
    Views
    846

    Quoting from the manual I found online somewhere:...

    Quoting from the manual I found online somewhere:

    The SERVICE indicator light shows when the water level probes have stopped working, and need to be cleaned (normally an indication of lime...
  17. Replies
    12
    Views
    859

    Yeah, they said gold on the packages. I got a...

    Yeah, they said gold on the packages. I got a staff guy over to quiz him, but he didn't have a clue.

    Take a peek at Lowes.com and search for gold drill bit. They come right up. On sale at a...
  18. Replies
    12
    Views
    859

    Nice tip with the hole saw, I'll be sure to pick...

    Nice tip with the hole saw, I'll be sure to pick one up.

    I've always used a good screwdriver and hammer and just punched the fan's sheetmetal off of the hub, to the back straight in. Takes a...
  19. Replies
    24
    Views
    1,327

    Bwahaha. Cute lil' toy you got thar, son. ...

    Bwahaha. Cute lil' toy you got thar, son. Might help with the one at home, but is absolutely worthless, in my experience, for a 5 HP Hobart with a fork in it. I've actually got one of those in...
  20. Replies
    24
    Views
    1,327

    That's what the 2x4 or crowbar will tell you...

    That's what the 2x4 or crowbar will tell you right away- if it turns at all, it's a bearing or electrical issue. If it doesn't turn, you've got something stuck, and you'll probably have to vac it...
  21. Replies
    24
    Views
    1,327

    >They always left a nasty stench - especially if...

    >They always left a nasty stench - especially if a torch was necessary to remove the stationary shredder

    And bringing it to the shop for repair, even if you bagged it, it would make your truck...
  22. Replies
    24
    Views
    1,327

    OK, I'll add my $.02 or so. We don't rebuild...

    OK, I'll add my $.02 or so.

    We don't rebuild anything 2HP or under. Doesn't add up. We do rebuild 3 to 5 HP ones now and then. I've gotten pretty good at them, made up some tools and pullers...
  23. Replies
    20
    Views
    1,185

    > The steamer is 9 years old. Holy canoli! 9...

    > The steamer is 9 years old.

    Holy canoli! 9 years old! It has more than paid for itself.

    The boiler kit comes with the high pressure safety/vacuum break thingy that screws onto the top.
    As...
  24. Replies
    20
    Views
    1,185

    I feel your pain. We work on a lot of these...

    I feel your pain. We work on a lot of these beasts, and for us charging like $90 and hour, it quickly makes economic sense to cut to the chase and buy a boiler and burner box. I understand how it...
  25. Replies
    20
    Views
    1,185

    As ECtofix says, that boiler is leaking. Don't...

    As ECtofix says, that boiler is leaking. Don't wast your customer's time and money. Pop in a new boiler and burner box assembly.