  1. Replies
    155
    Views
    23,854

    Could someone please send me the D-BACs...

    Could someone please send me the D-BACs application? Email is in my profile, Thanks!
  2. Replies
    5
    Views
    375

    I appreciate the help but i've tried connecting...

    I appreciate the help but i've tried connecting to this controller over a browser. No dice. I know the IP address and instance number but have no way to change them.

    This manual is for a chiller...
  3. Replies
    5
    Views
    375

    Awesome..can you elaborate? Everything i've read...

    Awesome..can you elaborate? Everything i've read so far says you need the McQuay service tools.
  4. Replies
    5
    Views
    375

    McQuay Microtech 2 BACnet IP

    I have 5 packaged RTU's that have incorrect (maybe the default) IP addresses and BACnet instance numbers. Does anyone know if these parameters can be accessed/edited via the keypad display? If not...
  5. Replies
    8
    Views
    927

    Are you using a 3rd party driver or Schneider's?

    Are you using a 3rd party driver or Schneider's?
  6. Replies
    5
    Views
    1,219

    Ok so I discovered that the Cbus card in the CPU...

    Ok so I discovered that the Cbus card in the CPU was the problem. I swapped the card with the one that WAS working and sure enough it worked fine. Got a new XD505a card and all is good. Thanks for...
  7. Replies
    5
    Views
    1,219

    Thanks for the reply Keith. I'm connected...

    Thanks for the reply Keith. I'm connected directly to the Cbus using an Infocon Easy IO Sedona controller that is flashed specifically for Cbus. The jace is talking to the Easy IO gateway via Cbus...
  8. Replies
    5
    Views
    1,219

    Honeywell XC5010

    Trying to integrate two of these panels to a Jace-6 using infocon's cbus driver and an easy IO gateway. I'm able to discover both panels and a point discovery in one of them works fine. All the...
  9. Replies
    7
    Views
    1,148

    I believe there is one for space temp control and...

    I believe there is one for space temp control and one for discharge air control. I would need the space temp control one but would certainly appreciate you sending both.

    I registerd on the Newron...
  10. Replies
    7
    Views
    1,148

    Trane LCI-R lon card commission Fail (AX)

    Pulling out an NAE and replacing with an FX-70.Trying to get 4 Trane LCI-R lon intergration cards commissioned in AX and get a "sendNormal" error (see attached). My guess is that the cards were...
  11. Replies
    2
    Views
    333

    Pretty sure I can help you out..Email is in my...

    Pretty sure I can help you out..Email is in my profile
  12. Replies
    18
    Views
    2,282

    It is my understanding that user privileges in...

    It is my understanding that user privileges in Insight are based on the Windows user account privileges. Is this incorrect?
  13. Replies
    18
    Views
    2,282

    Thanks for all the replies. P1nda that would be...

    Thanks for all the replies. P1nda that would be fantastic if you could provide me with any documentation for Insight 3.6. My email is in my profile.

    Randy, Thank you very much for taking the time...
  14. Replies
    18
    Views
    2,282

    The PC is owned by the county (not Siemens) and...

    The PC is owned by the county (not Siemens) and is not on any network. Completely stand alone, nothing even plugged into the Ethernet jack. It was setup by Siemens and there is absolutely only one...
  15. Replies
    18
    Views
    2,282

    Thanks for the reply. It is an XP pro machine...

    Thanks for the reply. It is an XP pro machine with SP2. I'll definitely try what you suggested but I'm still interested in restoring a backup in case something goes wrong and I do have to re-install...
  16. Replies
    18
    Views
    2,282

    Siemens Insight 3.6

    I have a customer that has a building with Siemens controllers and an Insight front end. Siemens setup the PC user account for the customer (a county superior courthouse) with no admin rights, thus...
  17. Thread: test

    by matt8085
    Replies
    0
    Views
    294

    test

    .
  18. Replies
    13
    Views
    1,527

    Could you send this my way as well? matt8085 at...

    Could you send this my way as well? matt8085 at yahoo dot com

    It would be much appreciated.
  19. Replies
    13
    Views
    679

    LOL!!!!!

    LOL!!!!!
  20. Replies
    13
    Views
    1,527

    Would you care to share?

    Would you care to share?
  21. Replies
    2
    Views
    635

    R2 Jace questions

    Okay...There are 2 issues that have been bugging the sh*t out of me for a while now, so i'll see if any of you guys can help me out here.

    R2 jace with TAC, I/A Lon controllers.

    In the lonworks...
  22. Replies
    19
    Views
    1,678

    Yeah, sometimes I even suprise myself...Not sure...

    Yeah, sometimes I even suprise myself...Not sure how I managed to mix up the two. My brain is melted. It's been a long day.
  23. Thread: Job Opp.

    by matt8085
    Replies
    10
    Views
    1,075

    I made the exact same switch. Did commercial...

    I made the exact same switch. Did commercial refrigeration & HVAC service for 8 years. Do it and never look back. I think alot of mechanical guys have the impression that control techs have it easy...
  24. Replies
    19
    Views
    1,678

    oops, got the NAE confused with an FX-40...Please...

    oops, got the NAE confused with an FX-40...Please delete this.
  25. Thread: Tridium

    by matt8085
    Replies
    8
    Views
    835

    Did you configure the I.P. on your laptop?

    Did you configure the I.P. on your laptop?