Yes, I cleaned the condenser after I saw the...
Yes, I cleaned the condenser after I saw the discharge pressure was like 350 and suction was above 100
-
07-04-2012, 12:19 PM
Thread: Is this normal operation?
by alex13177- Replies
- 12
- Views
- 798
R22
R22
-
07-04-2012, 12:45 AM
Thread: Is this normal operation?
by alex13177- Replies
- 12
- Views
- 798
That's what I told the owner that the system is...
That's what I told the owner that the system is running at max capacity. She doesn't believe me, said it used to run cooler inside. It is almost 100*F outside and the store front is west facing with...
-
07-03-2012, 09:50 PM
Thread: Is this normal operation?
by alex13177- Replies
- 12
- Views
- 798
Is this normal operation?
Rooftop package unit with TXV
Discharge pressure 285
Suction pressure 70
Sub cool 11
Superheat 30
Suction line temp 70*
Air across coil is 81* return and 61* supply
Also it was 96*F on the... -
05-06-2012, 07:10 AM
Thread: R-410 issues?
by alex13177- Replies
- 10
- Views
- 675
You need to flush out system and change out...
You need to flush out system and change out condenser and evap that can handle the higher pressure. Most of the time, you can use your old line set.
-
03-13-2012, 03:13 PM
Thread: digicool ak900 arrived
by alex13177- Replies
- 14
- Views
- 1,153
digicool ak900 arrived
just got my ak900 today. Can't wait to try it out!
-
03-10-2012, 05:35 AM
Thread: Hard start kit opinions.
by alex13177- Replies
- 48
- Views
- 2,341
anybody use the starter pow-are-paks with any...
anybody use the starter pow-are-paks with any problems?
-
03-01-2012, 10:13 PM
Thread: Limit swith compromised
by alex13177- Replies
- 9
- Views
- 332
if the limit is open then replace it
if the limit is open then replace it
-
03-01-2012, 10:05 PM
Thread: Fan getting hot?
by alex13177- Replies
- 11
- Views
- 420
replace capacitor first then check contactor
replace capacitor first then check contactor
-
02-26-2012, 03:48 PM
Thread: digicool ak900 or sman3?
by alex13177- Replies
- 40
- Views
- 2,615
Ok guys, I think I am going to buy the digicool. ...
Ok guys, I think I am going to buy the digicool. Now, where should I buy the digicool at?
-
02-22-2012, 11:06 PM
Thread: digicool ak900 or sman3?
by alex13177- Replies
- 40
- Views
- 2,615
I read that the temp wire on digicool breaks...
I read that the temp wire on digicool breaks easily . Is that true?
-
02-22-2012, 12:52 PM
Thread: digicool ak900 or sman3?
by alex13177- Replies
- 40
- Views
- 2,615
digicool ak900 or sman3?
I'm looking to jump on the digital gauge bandwagon. So hard to decide!
-
02-22-2012, 06:50 AM
Thread: condenser air temp.
by alex13177- Replies
- 18
- Views
- 846
you are right, I was thinking something else....
you are right, I was thinking something else. Brain fart!
-
02-22-2012, 06:23 AM
Thread: condenser air temp.
by alex13177- Replies
- 18
- Views
- 846
30* for r22 and 20* r410a?
30* for r22 and 20* r410a?
-
02-22-2012, 06:13 AM
Thread: checking super heat
by alex13177- Replies
- 31
- Views
- 1,556
I also believe that SH is lower with lower load....
I also believe that SH is lower with lower load. Would the EVAP be frozen at 22* saturation temp?
-
Thanks guys, I'm going to be doing mostly...
Thanks guys, I'm going to be doing mostly residential
-
Fuses
Hey guys,
What are some of the most common fuses you run into on service call that are blown? I want to buy all the fuses that I need to keep in the truck. -
02-10-2012, 12:05 AM
Thread: Recovering Machine?
by alex13177- Replies
- 10
- Views
- 946
thank you everyone for your feedback!
thank you everyone for your feedback!
-
02-09-2012, 08:47 AM
Thread: Recovering Machine?
by alex13177- Replies
- 10
- Views
- 946
Recovering Machine?
Hi, I'm new to this forum and I'm currently finishing up my HVAC degree. Which brand of recovering unit and vacuum pump do y'all seasoned veteran recommend?