  1. Thread: PMI Screen

    by tegger
    Replies
    4
    Views
    676

    re:

    Your correct. Our PC runs 24/7. We do reboot it about once a month due to the total physical memory building up.:patriot:
  2. Thread: PMI Screen

    by tegger
    Replies
    4
    Views
    676

    Re:

    After doing some 'confriguration of controller' and UNT's, upload/downloads. I rebooted our PC for the Metasys program and we are "now seeing the values change" on the screen for the AHU's, heating...
  3. Replies
    15
    Views
    1,486

    re:

    Cal1, our OA sensor Nickel probe is outside our wall into a parking ramp which is separated by 3"gap from our building block wall. It is in a conduit rectangle box connected to a 2x3 splice box. It...
  4. Thread: PMI Screen

    by tegger
    Replies
    4
    Views
    676

    PMI Screen

    Does any one know why my PMI screen on the Network Map when your in/on the AHU's screens doesn't want to "refresh itself" any more? All the CFM's or VFD's signals are not refreshing before your eyes...
  5. Replies
    15
    Views
    1,486

    re:

    We did find a spare one that we had on hand. I did remove the original one and ohm it out using a cup of water and using my portable thermostat to get the water to 70 degree. The ohm reading was...
  6. Thread: Mixed Air Temp

    by tegger
    Replies
    16
    Views
    1,914

    No, I have a new one on order. Then we will...

    No, I have a new one on order. Then we will change it out and see if it is the sensor. Just trying to find more info if anyone else has had this problem, Thanks
  7. Thread: Mixed Air Temp

    by tegger
    Replies
    16
    Views
    1,914

    re:

    No, the NCM 350 is through our DDC to the air handlers. We thought about switching the sensor the across coil face with another one which my guy said is about 20' long, to see if it does the same.
  8. Thread: Mixed Air Temp

    by tegger
    Replies
    16
    Views
    1,914

    Mixed Air Temp

    We have an issue with 1 of 4 AHU's mixed air temp. reading. It fluctuates about 8-10 degree in about 1 hr., which cause the relief damper to fluctuate open/close and the VFD to decrease/increase in...
  9. Replies
    15
    Views
    1,486

    I have a TE-6000-1 OA temp sensor that is reading...

    I have a TE-6000-1 OA temp sensor that is reading 18-20 degree higher then what the actual temp. is. How do I calibrate it through the DX-9100? What do I look for when I connect to the DX?
  10. Replies
    88
    Views
    12,493

    I have one NCM 350 PMI. I just got a error...

    I have one NCM 350 PMI. I just got a error message saying' cannot refresh vav window'. Is there something I can do about this? version 12.04
  11. Replies
    4
    Views
    575

    re:

    Were would it be listed in the GPL? Under what block? Unocc. Cooling? Or under the AHU's call for cooling block?

    I took some pics of the PC screen and I will figure out how to send them to you...
  12. Replies
    6
    Views
    598

    re:DX-9100 download

    I solve the problem with this issue by downloading the DOX5 file which rebooted the XT modules, which started all the equipment on the DX-9100, for thou of you who might run into this problem!:D
  13. Replies
    4
    Views
    575

    Metasys 12.04 PMI/Chiller Question

    We are operating JCI PMI version 12.04 BAS. We have a chiller that interfaces through a MicroTech to talk to Metasys. We have a DX-9100 for commuincation for cooling pumps, tower, chill pumps etc....
  14. Replies
    13
    Views
    1,691

    re:DX-9100 download

    I have my laptop connected to our DX and I want to download a XT module to re-boot it with a backup copy I downloaded from my PC. What is the simpleless steps to use? Thanks!
  15. Replies
    6
    Views
    598

    re:

    LETS BE/ACT PROFESSIONAL!!!!!!!!!!
  16. Replies
    6
    Views
    598

    re:reaper

    Thanks Reaper, I forgot to mention that it was on the DX-9100 for our chiller and heating loop. I notice the XT is flashing on the DX. I think it refer to one of the extension modules which Im trying...
  17. Replies
    6
    Views
    598

    XT#8 System Alarm

    I have an alarm today on my PMI Network Map showing red on the NC251-HW alarm. It happen to be raining outside and some thunder I was told, maybe a brown out. I'm trying to locate the problem but...
  18. Replies
    24
    Views
    2,673

    re:

    De nada
  19. Replies
    24
    Views
    2,673

    re:

    You are correct! I use a couple of different vendors that can repair older JCI components at a fractual cost compared to JCI. We are creating a CIP for 5 yrs. to upgrade every thing too current...
  20. Replies
    24
    Views
    2,673

    re:

    http://cgproducts.johnsoncontrols.com/default.aspx?main.aspx&2
  21. Thread: PMI/NC350

    by tegger
    Replies
    7
    Views
    631

    re:

    No we don't. I'm looking for a spare one base on the quote/price for a used one.
  22. Thread: PMI/NC350

    by tegger
    Replies
    7
    Views
    631

    Re:

    Can you verify what the pros or cons or benefits would be to go on a ADX server when we are currently running on a stand alone PC with mirror drives, WinXP,2.0 GB memory, GPL/PMI rev. 12.04 BAS with...
  23. We use 1- DX-9100 for our absorption chiller and...

    We use 1- DX-9100 for our absorption chiller and our hot water loop.
  24. Thread: PMI/NC350

    by tegger
    Replies
    7
    Views
    631

    re:

    Thanks
  25. Thread: PMI/NC350

    by tegger
    Replies
    7
    Views
    631

    Update, the software version we are using is...

    Update, the software version we are using is 12.04 for our NC350 with 4-DCM'S.
  26. Replies
    21
    Views
    1,327

    Do they pay you extra or increase your wage to do...

    Do they pay you extra or increase your wage to do this?
  27. Thread: PMI/NC350

    by tegger
    Replies
    7
    Views
    631

    PMI/NC350

    What is the current version that JCI is running on these systems with DCM's? 12.b?
  28. Replies
    21
    Views
    1,327

    RE:

    If there a problem! Do you wait until the next day or do you go in the same day/night to find the problem? How many problems/what kind of problems can you fix online?
  29. Thread: PMI manual.PDF

    by tegger
    Replies
    3
    Views
    1,932

    What is the current software version you are...

    What is the current software version you are using on the NCM? 12.b?
  30. Replies
    21
    Views
    1,327

    Remote Monitoring BAS

    How many BAS control techs are remotely monitoring there buildings from home? If so, are you paid extra for doing this?
  31. Replies
    24
    Views
    2,673

    Do you have any opinion on this?

    Do you have any opinion on this?
  32. Replies
    24
    Views
    2,673

    re:

    This is from a IT tech that works for the same company I do. He doesn't have any background in HVAC BAS. He was one of them that got sold on this ADX server and want us to help pay for it. He still...
  33. Replies
    24
    Views
    2,673

    Thanks for your input mechinc! :)

    Thanks for your input mechinc! :)
  34. Replies
    24
    Views
    2,673

    re:update

    We where told the other day, if we went on this server it would cost us $3100 p/yr for who know how long to go on the ADX server, to help pay for this server that has only 2 other NAE on it. I said...
  35. Do you still have any used DCM's?

    Do you still have any used DCM's?
  36. Replies
    24
    Views
    2,673

    RE: Does the NAE operate with Win XP OS kernel?...

    RE: Does the NAE operate with Win XP OS kernel? Or is this done from the OWS computer? Is the NAE a standalone controller/engine?
  37. Replies
    24
    Views
    2,673

    re:

    We are still using the PMI with the Extended Architecture because we need it for our DCM's and the VSD drives that were install on several pumps and tower fans. We don't have the cash to upgarde too...
  38. Replies
    24
    Views
    2,673

    re:

    We are connected with a NAE55, 2-DX9100, then we have a ethernet 350 NCM for the 4-DCM's. Now this was crazy! I was watching the RFSTATUS on the PMI map screen. As we were talking about it with my...
  39. Replies
    3
    Views
    487

    RF Status Current Sensor

    We are having an issue with one of our RF status. It keeps giving us a alarm after it start up, on and off 4-5 times through out the day. We replace the CS with a new one from JCI, but it still give...
  40. Replies
    24
    Views
    2,673

    re:

    No, it part of the 10 yr. contract for energy upgrades. They want us on the ADX with 2 other buildings. Through our fiber optic. I wondering is there issues with the ADX that will cause us not to...
  41. Replies
    24
    Views
    2,673

    Metasys/Extended Architecture

    If JCI needs to install or "update a file patch" as their programers develope them, to the software version. Is it just a matter of downloading the file to the NIE like you would download a file on...
  42. Replies
    17
    Views
    2,398

    Who is a vendor for the Signal software? The...

    Who is a vendor for the Signal software? The current PC is running Win 98 OS. Can the Signal software work on a Win XP OS system?
  43. Replies
    3
    Views
    510

    Windows XP Updates with Metasys

    Does anyone know if there is any problem with updating the Windows program running XP as the OS for our Metasys Extended Architecture software?
  44. Replies
    17
    Views
    2,398

    Is there away that a schedule button could be put...

    Is there away that a schedule button could be put on the graphic page of the boilers, so this could be brought out to the screen to make the change there?
  45. Replies
    17
    Views
    2,398

    Thank You for your help on this!! I was able to...

    Thank You for your help on this!! I was able to look at the current setting and the info will allow me too make the changes when needed! Thank You for the step by step on this!!:)
  46. Replies
    17
    Views
    2,398

    re;

    I'm at the screen now! GCM Barber Coleman
    Main Menu
    Current Status

    Then I hit 'enter' again and it went to 'no attributes'?
  47. Replies
    17
    Views
    2,398

    re:

    No , I'm not fimilar with that. I do have a copy of the manual. Is it in there some place?
    The tech that install it said he could change which boiler started first. This was a couple of years back...
  48. Replies
    17
    Views
    2,398

    RE:

    The window that opens is a [Boilers.ssf] [Run] window and it only show me the 2 boilers, 2 pumps, outside temp. and setpoints for OA Lockout and Hot water supply. I have adjustable window boxes under...
  49. Replies
    17
    Views
    2,398

    Signal 4.4.1 software

    I'm remotely monitoring a fire station using the Signal software 4.4.1. I want to check the 2 boilers schedule which they are to be alternating every other week. How do I find the schedule? Listed...
  50. Replies
    23
    Views
    2,785

    re:

    THANKS!! I'll bill JCI for this!:)