Not a love joy as we know from pumps now adays...
Not a love joy as we know from pumps now adays but more like a giant version found on glycol transfere pump. kind of a cross looking deal
-
03-05-2013, 07:01 PM
- Replies
- 6
- Views
- 484
Climatrol air handler 43years old looking for parts
Hi all hope someone out there can help. I have a climatrol air handler (cold deck,hot deck) mod. CM-32.00 ser. 13A69N-2.03 that has a two piece blower shaft with a rubber coupling between the two...
-
03-14-2012, 09:38 PM
Thread: Three Phase Compressor or Control Fault?
by MUNC- Replies
- 4
- Views
- 535
Whats the super heat? could the compressor not be...
Whats the super heat? could the compressor not be getting enough cooling of the windings from the refrig?
-
03-14-2012, 09:31 PM
Thread: what is this this fitting???
by MUNC- Replies
- 18
- Views
- 1,676
The thing kinda looks like a new automotive...
The thing kinda looks like a new automotive fitting huh??? Well last i heard it's for the factory charging and testing as the unit goes down the line, quicker to send the juice in that size...
-
01-16-2012, 09:20 PM
Thread: Water Cooled Heat Pump Problem
by MUNC- Replies
- 27
- Views
- 1,757
Have had to replace a few txv's on the water...
Have had to replace a few txv's on the water source pumps at one location in the past. Carrier units
-
01-16-2012, 09:15 PM
Thread: Pump down and crankcase heaters
by MUNC- Replies
- 15
- Views
- 1,337
Save washed out bearings as oil floats on the...
Save washed out bearings as oil floats on the liquid refrig. My vote is for cc heat
-
01-16-2012, 09:11 PM
Thread: intellipak building static issue
by MUNC- Replies
- 7
- Views
- 705
Exactly where i would have sent him, might add if...
Exactly where i would have sent him, might add if poss using same static station for both rtu's
-
12-30-2011, 11:18 AM
Thread: 3/8" HVAC hose to 1/4" HVAC male fitting
by MUNC- Replies
- 16
- Views
- 1,107
Fill me in, all I was saying is if your necking...
Fill me in, all I was saying is if your necking down the 3/8 hose whats the gain? Been pullin from my 3/8 thru manifold to both sides of system for years and get good, fast acurate evacs fine
-
12-29-2011, 11:14 AM
Thread: Trane YCD151 IDM never stops running
by MUNC- Replies
- 12
- Views
- 2,951
[/COLOR] To achive the -3.5 to -2.5"wc at gas...
[/COLOR]
To achive the -3.5 to -2.5"wc at gas valve before valve energized. Then set the -0.2". watch supply pressure 2" to 14" optimal 7" static and during operation shouldnt vary too much. -
12-29-2011, 11:06 AM
Thread: american standard heating issue
by MUNC- Replies
- 6
- Views
- 2,448
Is this thing a pressurized combustion chamber...
Is this thing a pressurized combustion chamber that needs the door on and sealed for proper operation? Have you checked the gas pressure( supply) while unit is firing to see if it drops off? ( bugs...
-
12-29-2011, 10:41 AM
Thread: 3/8" HVAC hose to 1/4" HVAC male fitting
by MUNC- Replies
- 16
- Views
- 1,107
Exactly, why even use the 3/8 hose?? It's for the...
Exactly, why even use the 3/8 hose?? It's for the four port man.
-
12-24-2011, 12:03 AM
Thread: Greatest Hits 2011
by MUNC- Replies
- 8
- Views
- 1,403
Frickin funny. Things people do. See much of the...
Frickin funny. Things people do. See much of the same up this way
-
12-23-2011, 11:45 PM
Thread: racing work vans
by MUNC- Replies
- 25
- Views
- 1,313
Two techs i worked with back in Chicago where...
Two techs i worked with back in Chicago where racing down I294, long story short lead guy started to lose his ladder and jammed on the breaks second guy didn't stop. Results??? Two totalled service...
-
12-23-2011, 11:27 PM
Thread: I need some help here!
by MUNC- Replies
- 5
- Views
- 499
Serviced a place the maintenance crew was using...
Serviced a place the maintenance crew was using the diconnect to cycle a pump. The thing got so worn out it would miss a "knife" from time to time and single phase the pump. The H.O.A. switch for the...
-
12-15-2011, 03:04 PM
Thread: Suction droppin into vacuum
by MUNC- Replies
- 12
- Views
- 2,935
Valves,unloader????. you amp compressor? have had...
Valves,unloader????. you amp compressor? have had bad comps out of the box, but rare. drier, liquid line sol? start from the beginning and happy hunting
-
12-15-2011, 02:59 PM
Thread: Trane YCD151 IDM never stops running
by MUNC- Replies
- 12
- Views
- 2,951
Have had quite a few stuck tco's. Make sure to...
Have had quite a few stuck tco's. Make sure to measaure and compare delta 't' to find why the tco tripped to energize fan circuit and get stuck there. Filters,belt,dampers,bypass ducted too close to...
-
12-14-2011, 08:34 PM
Thread: Old Modine Make Up Air
by MUNC- Replies
- 4
- Views
- 7,729
Could be zone averaging with all the stats,...
Could be zone averaging with all the stats, oooorrrrrr that old, how bout poss wheatstone bridge
-
12-14-2011, 08:16 PM
Thread: copeland semiherm troubleshooting
by MUNC- Replies
- 13
- Views
- 853
If this thing didn't have a low # cut out and...
If this thing didn't have a low # cut out and lost the juice prob fragged the comp.
no pumpin means no suction cooling thus " hot comp". If service valves, try pumpin it down, amp it and listen. if... -
12-14-2011, 08:06 PM
- Replies
- 8
- Views
- 833
Real nice to have trend logs of bearing temp and...
Real nice to have trend logs of bearing temp and oil sample results
-
12-14-2011, 08:01 PM
Thread: Trane voyager
by MUNC- Replies
- 27
- Views
- 1,494
Sounds like you don't have but need a lock up...
Sounds like you don't have but need a lock up reg____________________________________________________________
I re-read my post, forgot to put the " - " in front of .20, I knew what I meant so... -
12-09-2011, 05:13 PM
Thread: Trane Help
by MUNC- Replies
- 2
- Views
- 320
Have you tried comfort site?
Have you tried comfort site?
-
12-09-2011, 05:09 PM
Thread: Rooftop Heat Exchanger Failure Causes???
by MUNC- Replies
- 58
- Views
- 3,188
Since over seas started buying our beer cans and...
Since over seas started buying our beer cans and sending back x-chngs it's been a prob. Also everything else on a carrier. How many stripped screw holes can you count on one RTU?
-
11-30-2011, 11:46 PM
Thread: Suction accumulator
by MUNC- Replies
- 13
- Views
- 860
Def. need more info
Def. need more info
-
11-30-2011, 11:26 PM
Thread: Vav filters
by MUNC- Replies
- 13
- Views
- 973
You wouldn't believe how many fan powered vav...
You wouldn't believe how many fan powered vav boxes with electric reheat I've had to replace high limits on from over tripping, had to replace burnt wires and terminals and blower motors. all due to...
-
11-03-2011, 05:55 PM
Thread: Expansion tank
by MUNC- Replies
- 23
- Views
- 1,291
What about static head???? isolate and drain tank.
What about static head???? isolate and drain tank.