    Krack evaporator orifices

    I am working on a krack sk-24-78a evaporator and I was wondering if anybody could tell me the distributer orifice size for r-12 and also for when using r-22
  3. Replies
    2
    Views
    130

    Yeah purged thru for a couple minutes no signs of...

    Yeah purged thru for a couple minutes no signs of air
  4. Replies
    2
    Views
    130

    Baxi HT 1.330 boiling

    Has anybody messed around with a baxi ht 1.330 boiler with a plugged heat exchanger? I believe I have a plugged one because when the boiler ramps up to high fire it starts boiling big time. I had a...
  5. Replies
    1
    Views
    162

    Commercial Honeywell gas valve

    I am installing a commercial carlin burner and in the gas train is a Honeywell v48a2169 diaphragm gas valve. I was curious on the proper vent tube sizing for bleed port on this valve?
  6. Replies
    2
    Views
    206

    Maxitrol venting

    I am installing a commercial Carlin gas burner on a existing Smith boiler and I was wondering what vent line sizing guys were using on the maxitrols? I am installing a 325-7A maxitrol and a RV61...
  7. Replies
    1
    Views
    308

    Powerflame J50A-15HBS Burner Problems

    Im working on a hb smith 28A-6 hot water boiler with a powerflame J50A-15HBS natural gas burner. I cleaned boiler today and noticed that I was rumbling quite hard, also had been running really sooty....
  8. Replies
    29
    Views
    8,319

    Just curious if you guys out there are installing...

    Just curious if you guys out there are installing service switches at the indoor units with there ductless splits? I work with a master electrician that insists they must be there. We have been using...
  9. Replies
    7
    Views
    1,012

    Are you looking at using the hyper heat?

    Are you looking at using the hyper heat?
  10. Replies
    33
    Views
    3,465

    Ya 106 degrees that could have somethingto to do...

    Ya 106 degrees that could have somethingto to do with the compressor tripping on thermal haha
  11. Replies
    33
    Views
    3,465

    Sounds like to me you already have determined...

    Sounds like to me you already have determined atleast part of the problem with the hot air recirculation across the condenser coil.
  12. Replies
    4
    Views
    536

    Customer using a different brand product or...

    Customer using a different brand product or anything different in the product being used recently by any chance? Just trying to think outside the box haha
  13. Replies
    3
    Views
    885

    Great product from what i hear and i am actually...

    Great product from what i hear and i am actually gonna be installing one in the next two weeks
  14. Replies
    15
    Views
    1,131

    I now have apolicy to inform customer that there...

    I now have apolicy to inform customer that there may be other issues that caused the compressor to fail but wont know until compressor is replaced and additional costs and diagnosis maybe involved....
  15. Replies
    65
    Views
    3,652

    Well the only issue i see with that diagnosis is...

    Well the only issue i see with that diagnosis is that it runs properly in cooling he said
  16. Replies
    65
    Views
    3,652

    Really seems like a restriction is going on, in...

    Really seems like a restriction is going on, in piping in between units to me. I would add ports to the system at the inlet and outlet of the indoor unit and probably on either side of the drier as...
  17. Thread: MP 39 (401A)

    by sgagne199
    Replies
    21
    Views
    1,792

    I myself would convert back to 404a i like that...

    I myself would convert back to 404a i like that refrigerant
  18. Replies
    24
    Views
    4,143

    Have you checked to see if the plastic slides are...

    Have you checked to see if the plastic slides are installed under the fin tube against the fin tube supports for heat expansion and contraction? But that would make more of a clicking sound rather...
  19. I agree because if it has been working fine...

    I agree because if it has been working fine before and you have to adjust it to make it work again with different settings then something has obviously failed in the valve to mess it up.
  20. Replies
    9
    Views
    1,629

    Ok thats kinda what i figured thanks for the input

    Ok thats kinda what i figured thanks for the input
  21. Replies
    9
    Views
    1,629

    Flame rectification circuit

    On a electronic ignition intermittent pilot ignition control is there any known methods of testing the flame sensor besides measuring amperage? Was curious if any techs had different tricks or...
  22. Replies
    31
    Views
    11,931

    Yes they are available in the USA.

    Yes they are available in the USA.
  23. Replies
    15
    Views
    1,274

    Sounds Like you need to install some tattle tales...

    Sounds Like you need to install some tattle tales on some of those safeties
  24. Replies
    28
    Views
    2,391

    U got voltage at blower motor

    U got voltage at blower motor
  25. Replies
    12
    Views
    1,511

    Very good point baub i think i will try your...

    Very good point baub i think i will try your suggestion first before altering the unit
Results 1 to 25 of 76
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event