01-06-2012, 08:30 AM
Thread: Honeywell Globe Valve assistance please
by rnoel- Replies
- 1
- Views
- 439
Honeywell Globe Valve assistance please
Hello All,
At the facility I work at, as Plant engineer I came across a Honeywell chilled water valve with a packing leak. The I.D. tag on this valve has become stained and I cannot read the tag... -
09-19-2011, 08:46 PM
Thread: Steam boilers Q/A
by rnoel- Replies
- 8
- Views
- 1,228
Thanks for feedback guys..
Thanks for additional info guys..:o
-
08-29-2011, 08:33 AM
Thread: Steam boilers Q/A
by rnoel- Replies
- 8
- Views
- 1,228
Steam boilers Q/A
Need to brush up on steam boiler basics, possible interviews on the horizon. Been a little while since I’ve done start-up, checks etc, please add any omitted steps in start sequence. This would be at...
-
09-02-2009, 10:54 PM
Thread: Crank Case Pressure Regulator 'CPR' Opinion
by rnoel- Replies
- 2
- Views
- 706
Crank Case Pressure Regulator 'CPR' Opinion
Working on a 15" cubic lab freezer that uses a 'CPR' (CROT-6 0/60 -5/8) regulator. little vague on the operation of these sporlan regulators, but coming up to speed. I checked static pressure with...
-
08-16-2009, 06:37 PM
- Replies
- 28
- Views
- 1,483
Leaving unit in Vacuum overweekend Ok or Not
Seeking opinions
Working in shop on a cascade rebuild project. Got unit down to 250 Microns on this past Friday 8/14/09. Had to leave the shop for the weekend at closing, did not have time to... -
05-10-2009, 03:25 PM
Thread: Exhaust Static Info
by rnoel- Replies
- 0
- Views
- 218
Exhaust Static Info
'Commercial' Got feedback?
Preparing to tie in a ‘Down Draft Torit bench’ into the existing exhaust system for an industrial manufacturing room. I have limited experience in the ducting area,... -
05-08-2009, 08:39 AM
Thread: McCall Reach in unit. Low to Medium temp?
by rnoel- Replies
- 1
- Views
- 309
McCall Reach in unit. Low to Medium temp?
Need to temporarily adjust the use of a McCall reach in upright freezer and convert to thirty-eight degree refrigerator temperature unit. The customer recently moved into this facility and they...
-
04-24-2009, 01:03 AM
Thread: Climate Master water source H/P problem
by rnoel- Replies
- 2
- Views
- 377
Thanks for reply Chillerguy, did not run unit in...
Thanks for reply Chillerguy, did not run unit in heat mode yet, will test unit in heat mode on return. Also this unit is an older version I take it, this unit uses two blue wires on 'LTS' safety with...
-
04-23-2009, 10:20 PM
Thread: Climate Master water source H/P problem
by rnoel- Replies
- 2
- Views
- 377
Climate Master water source H/P problem
Model: HS090FSZSLSGCSA
CXM: Controller
On-site staff has been continually resetting unit upon auto safety shut downs. I was able to catch unit in a fault state of 'LTS' (low temp switch) LED... -
04-21-2009, 01:24 AM
Thread: Compessor ground 'flush or no flush'
by rnoel- Replies
- 7
- Views
- 536
Compessor ground 'flush or no flush'
Got a couple good replies to this one on another posting thread. Anyone with additional suggestions welcome:rolleyes:
Found compressor grounded on this heat pump, backed that up with supco megger... -
03-31-2009, 07:25 PM
Thread: Scotsman Bin eyes Q/A
by rnoel- Replies
- 7
- Views
- 519
Thanks all good info; And agreed Icemeister,...
Thanks all good info; And agreed Icemeister, after full clean and sani of scotsman including water filter replacement, the nuisance 'no ice sensed during harvest & false bin full signals have...
-
03-30-2009, 08:47 PM
Thread: Scotsman Bin eyes Q/A
by rnoel- Replies
- 7
- Views
- 519
Scotsman Bin eyes Q/A
Scotsman (CME806AS-32D)
Was asked by my supervisor to look into the possibility of limiting the amount of water 'oversplash' from the trough area during the freeze cycle that tends to splash on bin... -
02-12-2009, 12:33 AM
Thread: Carrier 2 stage H/P Frosty
by rnoel- Replies
- 3
- Views
- 429
Thanks for the heads up 'Jimmyhoffa' - Unit...
Thanks for the heads up 'Jimmyhoffa'
- Unit frosting in heat mode!
- Day temperatures mid 60's F
- Night temperatures drop as low as 25 degrees F
rnoel -
02-11-2009, 09:11 PM
Thread: Carrier 2 stage H/P Frosty
by rnoel- Replies
- 3
- Views
- 429
Carrier 2 stage H/P Frosty
Co-worker attempted repair of this unit with out success.
Model: 50HJQ008-621 (Two stage)
Carrier
He has replaced:
~Both outdoor coil sensors
~ The defrost board
~ Checked refrigerant charge... -
02-09-2009, 08:06 PM
Thread: Carlyle O6D CCH info
by rnoel- Replies
- 7
- Views
- 461
Thanks Klove, and away to totaline I go..
Thanks Klove, and away to totaline I go..
-
02-09-2009, 07:48 PM
Thread: Carlyle O6D CCH info
by rnoel- Replies
- 7
- Views
- 461
Carlyle O6D CCH info
Crankcase heater replacement. Does the new heater come with some type of heat transfer gel that would be added to the heater well?
Is this a relatively simple replacement? As the wires burned off... -
01-28-2009, 07:54 PM
Thread: Scotsman CME cuber 'bin ice' control
by rnoel- Replies
- 3
- Views
- 598
Scotsman CME cuber 'bin ice' control
Looking to replace the problematic 'bin ice' control eye's. Any tips are welcomed.
e.g. Any parts to move such as evaporator sump tray? Would one use some old wire or pull string to attach to wire... -
01-27-2009, 11:14 PM
Thread: Bryant/Daynight HP
by rnoel- Replies
- 2
- Views
- 276
Thanks 'beenthere' info helpful today. Thanks for...
Thanks 'beenthere' info helpful today. Thanks for the Fasco Tip..
-rnoel -
01-26-2009, 10:32 PM
Thread: Bryant/Daynight HP
by rnoel- Replies
- 2
- Views
- 276
Bryant/Daynight HP
Older Bryant/Daynight Heat pump
Model number faded away on unit, only numbers present or '654A'
208V single phase unit and blower with capacitor
Unit evaporator was fully iced up. Placed unit... -
01-16-2009, 01:33 AM
Thread: 460 Volt 's/p' run capacitor 'question'
by rnoel- Replies
- 11
- Views
- 1,397
Thanks all- Wiring all ok; turned out to be...
Thanks all- Wiring all ok; turned out to be faulty motor from wholesale distributor (tight) having fire barn sale on some carrier parts. Needless to say won't be using them in future!!
- Thanks for... -
01-13-2009, 11:57 PM
Thread: 460 Volt 's/p' run capacitor 'question'
by rnoel- Replies
- 11
- Views
- 1,397
Thanks for the replies guys.. good info. ~...
Thanks for the replies guys.. good info.
~ Little john
did you confirm that the new capacitor is operational? did you confirm that you have 460V between the two legs to the motor? did you... -
01-13-2009, 08:01 PM
Thread: 460 Volt 's/p' run capacitor 'question'
by rnoel- Replies
- 11
- Views
- 1,397
460 Volt 's/p' run capacitor 'question'
460 Volt single phase capacitor run schematic
Older Carrier Heatpump-5 ton
Model: 50NQ060600
Mtr model: GE type (5KCP39PG) 'P234AS' (460v) single phase
Wired up new motor O/D condenser... -
01-07-2009, 10:15 PM
Thread: Hey york56
by rnoel- Replies
- 1
- Views
- 298
Hey york56
Hello york56,
Check your email in box for additional Q/A..
Thanks-rnoel -
Hello york56, Check your email in box for...
Hello york56,
Check your email in box for additional Q/A..
Thanks-rnoel -
York 'YT'
Looking for downloadable 'service manual' for the YT (YTH1B2C3-CKJ)
Thanks.;)