Search:

Type: Posts; User: jeffinok

Search: Search took 0.00 seconds.

  1. Replies
    26
    Views
    3,029

    i would tell him to call me when hes ready for a...

    i would tell him to call me when hes ready for a new furnace . i wouldnt want to be responsable
    for that hacked up mess!!
  2. Replies
    65
    Views
    4,741

    my new favorite tool is a hydrualic swaging tool....

    my new favorite tool is a hydrualic swaging tool. makes fitting and sweating copper alot easier.
    only one joint to sweat instead of two with a coupling ..
  3. Replies
    19
    Views
    756

    i gave myself a new dewalt heated jacket ... ...

    i gave myself a new dewalt heated jacket ... its warm!!!!:grin2:
  4. Replies
    16
    Views
    1,221

    i like the klein 612-4 1/8" Terminal Block...

    i like the klein 612-4 1/8" Terminal Block Screwdriver also it has the small tip for working on thermostats but it has a regular size handle . much better to keep my hands from cramping up...
  5. Replies
    5
    Views
    441

    three phase compressures will run backwards for a...

    three phase compressures will run backwards for a short time . i know this from doing startups .
    you have to check for proper rotation on three phase the first time you start up a unit. just...
  6. my vacuum pump wouldnt pull below 576 on my...

    my vacuum pump wouldnt pull below 576 on my micron gauge .
    i tried what the guy did in the last post here ...
  7. Thread: 30 + 30= 60??

    by jeffinok
    Replies
    41
    Views
    2,090

    thanks for the replys. i know in series what...

    thanks for the replys.
    i know in series what ever two you combine halves it . just wanted to make sure i could mix and match uf ratings in parrallel . again thanks
  8. Thread: 30 + 30= 60??

    by jeffinok
    Replies
    41
    Views
    2,090

    question on the subject. i was told when you...

    question on the subject. i was told when you parrallel two capacitors they must be the same uf .
    example 10+10=20 . said you couldnt put a 10uf with another uf rated cap such as a 5uf? is this...
  9. Replies
    41
    Views
    5,978

    doesnt anybody run metalpipe anymore? instant...

    doesnt anybody run metalpipe anymore? instant pipe in a bag .
    glad thats not going in my house:Faint:
  10. Thread: hello

    by jeffinok
    Replies
    5
    Views
    282

    thanks for the welcome . i have wired new units...

    thanks for the welcome . i have wired new units , pulled copper , checked roof tops on start ups ,adjusted belts checked pullys under the supervision of a service tech on a multiple unit start up ...
  11. Thread: Snips

    by jeffinok
    Replies
    17
    Views
    806

    as stated midwest seems to hold up the best for...

    as stated midwest seems to hold up the best for me. i have tried malco wiss and several others over the years .
  12. Thread: hello

    by jeffinok
    Replies
    5
    Views
    282

    hello

    hello, my name is jeff . i have been fabricating and installing commercial sheetmetal jobs for the last 16 years . i would like to do service . i know the basics of the systems just not the details....
  13. im glad i had the priviledge of working with an...

    im glad i had the priviledge of working with an old school sheetmetel worker for my first 6 years . i have been doing sheet metal for 15 years now . just getting into service . theres no book i have...
  14. if i didnt know the person i was buying it from i...

    if i didnt know the person i was buying it from i wouldnt.
    i need to trust my meter . you make your living with this and use it every day if you spend $ 96 and not everything works you now have to...
  15. Replies
    12
    Views
    1,946

    wow is all i can say!!!! that coil is definately...

    wow is all i can say!!!! that coil is definately choked on air flow . it looks like they had plenty of clearance around
    the coil and furnace to do it right.
  16. Replies
    6
    Views
    1,628

    i have made replacement doors out of sheetmetal...

    i have made replacement doors out of sheetmetal never tape :gah:.

    dont they know your supposed to use duct tape not fsk? :gah::bump::grin2: lol
  17. Replies
    7
    Views
    1,596

    more return is an understatement. poor blower...

    more return is an understatement. poor blower motor is starving
  18. Replies
    7
    Views
    918

    might want to check your local codes . ductwork...

    might want to check your local codes . ductwork run in an unconditioned space isnt up to code around here.
  19. Replies
    38
    Views
    5,112

    midwest offsets are my favorite . have tried many...

    midwest offsets are my favorite . have tried many over the last 16 years
Results 1 to 19 of 19
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event