Search:

Type: Posts; User: AiResearch

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    71
    Views
    4,907

    Wait a minute guys, if you look at Red Wings web...

    Wait a minute guys, if you look at Red Wings web site, at the pull on Pecos in particular, you will see 99% of that particular line is USA and goes for around $200. Personally I think the hand made...
  2. Replies
    71
    Views
    4,907

    Just wondering Turbo, if you are only using your...

    Just wondering Turbo, if you are only using your MB, and the larger ones are in the garage, what are you carrying (the rest of) your service tools in at the moment?

    I do agree with you about the...
  3. Replies
    11
    Views
    1,861

    There are many different levels of quality,...

    There are many different levels of quality, price, experience and company of the tradesman, etc...

    Perhaps the customer got a good value on this one considering what they paid.

    If someone is...
  4. Since you only have 2 stages of cooling, why not...

    Since you only have 2 stages of cooling, why not change it up from the norm and bring on the refrigeration based on OAT? This will also help minimize cycling.
  5. Replies
    20
    Views
    1,919

    Must have been a mis-manufactured compressor. ...

    Must have been a mis-manufactured compressor.

    A plugged drier would not have spiked the current draw in a system with a proper charge. Especially not in a system with a low charge. It would have...
  6. Replies
    20
    Views
    1,919

    Thank ya for the update I experienced the same...

    Thank ya for the update

    I experienced the same

    Maybe the cylinder was a lil tighter than expected...
  7. Replies
    20
    Views
    1,919

    There may still be an electrical problem, but...

    There may still be an electrical problem, but does sound like a restriction upstream of the liquid line, those will raise the current consumption in a heartbeat.

    This reminds me I had one of...
  8. Replies
    20
    Views
    1,919

    It may be time for a piercing valve on the...

    It may be time for a piercing valve on the discharge line before anything else. Only takes a minute.

    Is this a capacitor start and run compressor with a potential relay? Seems like I remember...
  9. No prob good luck!

    No prob good luck!
  10. Okay well that clears up a bit. The next...

    Okay well that clears up a bit.

    The next question would be head pressure control. 50F is not too friendly for a standard RTU.

    You had some load inside, adding some load outside by covering...
  11. If the OP has an 80F return, chances are he has...

    If the OP has an 80F return, chances are he has an 80 plus ambient, and he should be running a higher discharge pressure even with reduced evaporator airflow. Assuming the capacity of the new tandem...
  12. Sounds like you did a good job. No mention of...

    Sounds like you did a good job. No mention of ambient. Discharge is low, add more refrigerant and see what happens.
  13. Replies
    204
    Views
    31,446

    Arc AAA led keychain USA The light can be...

    Arc AAA led keychain USA

    The light can be carried at all times

    Very impressive performer
  14. Replies
    6
    Views
    642

    Interesting. Serious water pressure. Is there a...

    Interesting. Serious water pressure. Is there a reason to close both lines and leave the coil with no room for expansion?

    Seen it done both ways - close the leaving - close the entering.

    In...
  15. Replies
    25
    Views
    6,138

    I would say one with a level of sophistication.

    I would say one with a level of sophistication.
  16. Replies
    16
    Views
    1,971

    A small bit of information- Variable air...

    A small bit of information-

    Variable air volume is a different system altogether than a constant volume zone control.

    VAV is used on large central equipment with capacity control.

    Zone...
  17. As I send from my iPhone. Shakes head. ...

    As I send from my iPhone.

    Shakes head.

    Shame on me.

    I need to run up to the store now.

    For some liquid refreshment (dinner)
  18. haha I get a feeling you are with me on this ...

    haha
    I get a feeling you are with me on this

    generally I frown on modern society
  19. Personally myself, do not care for these emerging...

    Personally myself, do not care for these emerging nu skool resi and retail service organizations, who are concerned with regional dominance and never ending growth, more so than actually doing real...
  20. Replies
    71
    Views
    11,217

    So the purge discharges into the cylinder instead...

    So the purge discharges into the cylinder instead of the atmosphere?
  21. Replies
    71
    Views
    11,217

    Hello Rob, could you or someone else identify...

    Hello Rob, could you or someone else identify that "propane tank" on the side of the condenser for those of us not intimately familiar with low pressure refrigeration?

    It appears to be a factory...
  22. Replies
    25
    Views
    6,138

    I'm my experience, it has been the opposite. The...

    I'm my experience, it has been the opposite. The mom n pop shops are doing better work than the big guys with many workers. (exception being large mechanical contractors who have a standard of...
  23. Replies
    27
    Views
    3,138

    Tech Rob mentioned Snap-On and the like. I...

    Tech Rob mentioned Snap-On and the like.

    I have few of their pieces that were handed down.. Very nice and functional. I can't afford them. More for auto mechanics that use those types of tools...
  24. Replies
    25
    Views
    6,138

    Cheap and fast.. We were just talking about...

    Cheap and fast..

    We were just talking about that today. Contractors doing installations for peanuts, spending little time on the job and exhibiting no workmanship, making the other contractors who...
  25. Replies
    25
    Views
    6,138

    That is a good question. My thoughts are, if you...

    That is a good question. My thoughts are, if you were speaking practically, in real world operation, the exact bulb location does not make too much of a difference. Provided it is securely fastened...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event