Search:

Type: Posts; User: rmorningstar

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Anyone?

    Anyone?
  2. Carrier 3V Integration with Honeywell WEBs-AX

    Has anyone tried integrating a Carrier 3V system with Honeywell WEBs-AX system using the Carrier CCN driver?

    Thanks,
    Russ
  3. Replies
    12
    Views
    2,134

    If you encounter the Plugin poping up, look at...

    If you encounter the Plugin poping up, look at the top address bar and see if a red "block" icon has appeared...if so, click on it and then click on "Activate all Plugins" then select "Always...
  4. Replies
    14
    Views
    980

    Is there a newer version of the Spyder Tool than...

    Is there a newer version of the Spyder Tool than 3.5.34.5.18 (Using LON)? Or are you referring to the expected release of the new tool scheduled to be released at the end of April?
  5. Replies
    14
    Views
    980

    Thanks, Did lwarren say if this help increased...

    Thanks, Did lwarren say if this help increased the Spyder download speed/time?
  6. Replies
    14
    Views
    980

    Does it matter much if the LON bus was ran as a...

    Does it matter much if the LON bus was ran as a TP/FT-10 daisey chain style? Is this why the bus is so slow and the downloading to the individual Spyders takes so long? Should a different backbone...
  7. AX - Platform Running Low on RAM Disk Space

    I have a Honeywell WEBs AX JACE 600 that has been running since September. Here recently the following warning has appeared in a yellow box "Platform Running Low on RAM Disk Space". Is this due to...
  8. Ok...thanks for your help Digo.

    Ok...thanks for your help Digo.
  9. JACE 600 AX History & Alarm Archive to External Hard Drive

    Is there a way to send History and Alarm Archive information from a JACE 600 AX to an External Hard Drive without using a PC on the customer’s network? I would like to install an External Hard Drive...
  10. Replies
    15
    Views
    2,963

    Yes, its Spyder Tool 5.0. Due to release late...

    Yes, its Spyder Tool 5.0. Due to release late summer or early fall of 2011.
  11. Replies
    8
    Views
    1,318

    Ok...I'll wait for their responce. Thanks again!!

    Ok...I'll wait for their responce. Thanks again!!
  12. Replies
    8
    Views
    1,318

    Thanks orion242...I appreciate your help... Am I...

    Thanks orion242...I appreciate your help...
    Am I correct in assuming that they will send me pricing in responce to my email to their "Contact Us"?
  13. Replies
    8
    Views
    1,318

    They are using IQ220's...Sorry, I don't know much...

    They are using IQ220's...Sorry, I don't know much about Trend products.
  14. Replies
    8
    Views
    1,318

    Integrate Trend into Honeywell AX

    Can a Trend control system be integrated into a Honeywell WEBs AX system? Are there drivers available for the Trend?
  15. Replies
    15
    Views
    2,963

    Yes, we have experienced some of the pains of the...

    Yes, we have experienced some of the pains of the Spyder…However, after seeing the new Spyder tool at HW Momentum conference…They have definitely improved the tool and the Venom tools…let’s just say...
  16. Replies
    9
    Views
    957

    I like using my Fieldpiece multi meter since it...

    I like using my Fieldpiece multi meter since it has a built in capacitor testor and thats one less meter that I have to carry around. However, I always recomend discharging the stored energy in the...
  17. Thread: New job

    by rmorningstar
    Replies
    8
    Views
    778

    Best advice is to get as much training as...

    Best advice is to get as much training as possible from them, don’t be afraid to ask questions, and always be honest with your boss and fellow techs (especially about your abilities and skills). As...
  18. Ok, I checked and there are two VAV2 templates...

    Ok, I checked and there are two VAV2 templates already created in the Template Wizard:

    (Template Name) USdefault (Template File Name) lps_usdefault_xl10vav.xml

    &

    (Template Name)...
  19. Are you referring to creating an XML from Quick...

    Are you referring to creating an XML from Quick Builder? I have never done this and I looked in the "Tools" menu in Quick Builder and I don't see a Wizard for creating the XML in R300.
  20. Keith thanks for your help. I verified the...

    Keith thanks for your help. I verified the display builder file (SysDtlLpsVavGen.dsp) and looked at the point (App.nvoData.UbDamperPosS1) for the damper position. It is there in the file, so I’m...
  21. SymmetrE - VAV Box Graphic not Displaying Damper Position

    Anyone ever lose just a single graphic point from all XL10's in SymmetrE? I have an old SymmetrE R-300 system that is not displaying none of the VAV box graphic damper positions. All the other VAV...
  22. Thread: hey

    by rmorningstar
    Replies
    6
    Views
    679

    Welcome

    Welcome
  23. Thread: F.N.G.

    by rmorningstar
    Replies
    5
    Views
    647

    Welcome.

    Welcome.
  24. Thread: Hello!

    by rmorningstar
    Replies
    3
    Views
    555

    Welcome.

    Welcome.
  25. Replies
    13
    Views
    1,486

    Welcome.

    Welcome.