  1. Your humidifier (which adds humidity to the air)...

    Your humidifier (which adds humidity to the air) only works when the unit is heating, it will not come on when the unit is cooling. Cooling will dehumidify only.

    There is no "easy" way or...
  2. Replies
    21
    Views
    1,680

    The warranty on your equipement is still good, no...

    The warranty on your equipement is still good, no problems with being a new owner. That being said, as mentioned earlier until the restriction is found (if there is one) there is no way to know if it...
  3. Replies
    21
    Views
    1,680

    Restriction can also come from abuse if one of...

    Restriction can also come from abuse if one of the lines is hit or smashed.

    You need to call the company and request a different tech as a competent tech can tell where the restriction is by...
  4. Replies
    8
    Views
    1,564

    The only thing that should be used to "flush" the...

    The only thing that should be used to "flush" the lines is nitrogen, Carrier very strongly says not to use anything else. Agreed he should have used a micron gauge to measure the vacuum.

    I doubt...
  5. Replies
    14
    Views
    8,767

    Install Minimum Load Valve (Hot Gas Bypass)...

    Install Minimum Load Valve (Hot Gas Bypass) option. All the setting above may help but ultimately the problem is the machine's lowest capacity is greater that your load. MLV should resolve the issue.
  6. Replies
    8
    Views
    1,128

    He is a great guy and I would have no problem...

    He is a great guy and I would have no problem working for him again, but I am pretty comfortable where I am and plan to stay. I know he hates to lose you.
  7. Replies
    8
    Views
    1,128

    Hey man, good luck and stay in touch!

    Hey man, good luck and stay in touch!
  8. Replies
    9
    Views
    661

    Not commenting on the SH, SC, or pressures but...

    Not commenting on the SH, SC, or pressures but there may be nothing wrong with a 13 deg drop. In fact that may be great! Your temp drop will depend on how much of your cooling capacity is going to...
  9. It could be due to many things, including being...

    It could be due to many things, including being too small. However, there is no way anyone here can tell what the problem may be without looking at it. Call the installer and have them check the...
  10. You need to call a service tech rather than...

    You need to call a service tech rather than resetting the alarm. The codes you reference are that the chill water pump is not running. Resetting the alrams could cause the water tubes to freeze and...
  11. Replies
    33
    Views
    2,343

    The equipment manufactuer has no control over the...

    The equipment manufactuer has no control over the static. Static is a function of the duct system (which the equipment manufacturer does not provide). Carrier does however tell the installer if it is...
  12. The dealer will have to contact his distributor...

    The dealer will have to contact his distributor and see if one is available or can be ordered. This unit is not as widely stocked by the distribution channel.
  13. Replies
    28
    Views
    1,805

    Agreed, blade position is first thing to check...

    Agreed, blade position is first thing to check and often resolves any issues. Have them try this before changing the motor.
  14. Replies
    18
    Views
    1,417

    Because occasionally things happen for no real...

    Because occasionally things happen for no real reason, like the power pole example I gave earlier. If it was on the display people would get all bent out of shape for no reason (sound famaliar? lol)....
  15. Infinity will only work with one model air...

    Infinity will only work with one model air handler, the FE. There is no such thing as an FE4BWF. As mentioned earlier this is most likely an error or poor penmanship. Either way the FE is the...
  16. Replies
    18
    Views
    1,417

    The code has already told you what happened, from...

    The code has already told you what happened, from your own writing, the thermal overload opened. There are many things that can cause this and only an inspection of the unit and its operation by...
  17. 58STA is not an older model, it is current...

    58STA is not an older model, it is current production equipment. However, it is the standard grade 80% furnace.
  18. If you have a 58MVB then you do not have a 3...

    If you have a 58MVB then you do not have a 3 stage furnace, the MVB is a 2 stage unit. 58mvC is the three stage unit.

    The run time is whole hours, so until your unit runs in that stage for at...
  19. Thread: 410a

    by plain spoken
    Replies
    28
    Views
    2,180

    Still does not make it accepted by equipment...

    Still does not make it accepted by equipment manufacturer. I am merely quoting what the installation instructions (offcial manufacturer document) says.
  20. Thread: 410a

    by plain spoken
    Replies
    28
    Views
    2,180

    Flux + POE = ACID, no flux allowed. This is one...

    Flux + POE = ACID, no flux allowed. This is one of the reasons, along with joint strength, that Carrier/Bryant installation instruction for R410A units says BRAZE ONLY.
  21. Replies
    23
    Views
    3,022

    It will be difficult if not impossible to know...

    It will be difficult if not impossible to know the price difference (if any). There are many reasons that prices will be different and a very small part of this is the brand of the equipment. One...
  22. Only if you call communicating every 8/10 of a...

    Only if you call communicating every 8/10 of a second slow. Sounds like the guy is feeding you a line of bull....may have to wonder about what else he is telling you.
  23. Replies
    19
    Views
    2,053

    The "Pro" will know the answer, other wise hire a...

    The "Pro" will know the answer, other wise hire a real pro.
  24. Infinity can control Carrier ERV/HRV but not...

    Infinity can control Carrier ERV/HRV but not third party such as yours.
  25. The configurations will remain forever, the time...

    The configurations will remain forever, the time will hold for at least 72 hours. Be careful taking it off and reinstalling it. Grasp it on each side and rock back and forth to take it off the wall...