    Jumper PJ4 is cut on Goodman AH

    I have a Goodman AH for A/C only; primary heat is from a boiler. I decided to install a 15kw heat kit for emergency/backup heat in case the boiler would fail. When I looked at the variable speed tap...
  2. Replies
    6
    Views
    781

    Take a look at the type of igniter that is being...

    Take a look at the type of igniter that is being installed. There are two versions. One is a very shiny white porcelain unit and the other is a dull white "bakelite" type material (OEM). Have your...
  3. Replies
    2
    Views
    482

    So, the factory installed jumper between R&BK...

    So, the factory installed jumper between R&BK should be removed, correct? The Comfort-R pocket guide says to keep the jumper in for Enhanced Mode, is this not correct for this application?

    What...
  4. Replies
    2
    Views
    482

    803TStat wiring for Trane XL15i

    Installing a Trane 803 TStat on a Trane 3.5 ton, XL15i single stage AC unit and a Trane VS air handler with one 10kw heat strip. I want Enhanced Mode enabled as well as the humidistat...
  5. Replies
    1
    Views
    395

    Trane 803 TStat and Outdoor Sensor

    The install manual says you can't use the same wire bundle to wire the outdoor sensor and that you have to run a separate cable. Anyone know why? Has anyone used a pair of unused wires in the bundle?
  6. Replies
    303
    Views
    25,740

    Jeff - You've been emailed...

    Jeff -

    You've been emailed...
  7. Replies
    303
    Views
    25,740

    Jeff - Where did you get the junction box?

    Jeff - Where did you get the junction box?
  8. Replies
    5
    Views
    1,417

    I have the same TStat - is the backlight the very...

    I have the same TStat - is the backlight the very dim display that is on all the time and then when you touch the panel, the display gets consierably greener and brighter?
  9. Replies
    12
    Views
    1,921

    I'm in the same situation. I had a dealer tell me...

    I'm in the same situation. I had a dealer tell me the exact same thing that the XL14 is capable of 15 SEER. Can you tell me what the "right air handler and coil" is to achieve 15 SEER?
  10. Replies
    6
    Views
    738

    Perfect Fit or Clean Effects?

    I'm trying to compare two Trane units. One contractor is quoting a 4TEE3D40A1000A that has Clean Effects already installed and the other dealer is quoting a 4TEE3F40A10001 unit with a Perfect Fit...
  11. Replies
    8
    Views
    2,237

    I was told by the dealer that the XR series...

    I was told by the dealer that the XR series increases the warranty to 10/10 for parts and labor.
  12. Replies
    8
    Views
    2,237

    Okay - here are the model numbers: A/H:...

    Okay - here are the model numbers:

    A/H: 4TEH3F42B1000A

    A/C: 4TTR4042C1000A
    _____________________________________

    A/H: 4TEH3F42B1000A

    A/C: 4TTR4042A1000A
  13. Replies
    8
    Views
    2,237

    Trying to compare Trane quotes - Need help

    Three of the dealers have been quoting the XLi15 a/c and the 4TEH3F42B1000 a/h with one 10kw heat strip.

    The fourth dealer is quoting a XR14 a/c with the same a/h as above. He told me that the...
  14. Replies
    303
    Views
    25,740

    Still no pics...

    Still no pics...
  15. Jusst so everyone understands - I'm not trying to...

    Jusst so everyone understands - I'm not trying to screw the contractor by not paying. I also don't want to be preceived as having a hissy fit over my concerns. I was just trying to figure out if the...
  16. No straps and no beam. The unit is hung with with...

    No straps and no beam. The unit is hung with with 3/8 threaded rod from the ceiling to slotted angle cleats. There are two sloted angle cleats located across the A/H at each end, about a third of the...
  17. Yes there is an auxillary drain pan...

    [QUOTE]

    Yes there is an auxillary drain pan beneath the unit and no overflow drain swith. The A/H in suspended from the ceiling in my garage.



    Ok - so why does the install manual state to...
  18. Bob - So because I read the installers guide,...

    Bob -

    So because I read the installers guide, that means I am micro managing? How am I burning your onion by asking the installer to do the install as per the manufacturers instructions? Why have...
  19. Yes a permit was pulled and it did pass...

    Yes a permit was pulled and it did pass inspection. The items listed in my original post would not have triggered a failed inspection.

    As I stated origially, I have no problem paying the bill in...
  20. Beenthere - They were not the lowest bid -...

    Beenthere -

    They were not the lowest bid - what makes you think it "sounds" like it?

    Why would you think installing another support or installing the trap near the A/H would cost more or not be...
  21. Do I pay all, half or none of the bill on a Trane install?

    I recently had a Trane XL16i(4TTX6), a Trane 3 ton a/h (4TEE3F40) with 10 KW heat and a Trane TCONT803 TStat.

    I have not paid the invoice because of the following reasons:

    1. The installers...
  22. Replies
    10
    Views
    2,408

    The heat transfer medium is the Wirsbo QuickTrak...

    The heat transfer medium is the Wirsbo QuickTrak system that are 1/2" plywood panels that have grooves in them for the PEX tubing with an aluminum backing on them. The MVA's are failing about every 3...
  23. Replies
    10
    Views
    2,408

    Wax actuators:...

    Wax actuators: http://na.heating.danfoss.com/xxTypex/156011_MNU17420014_SIT209.html

    I was using the Wirsbo actuators quite a few years ago and those would fail in the open position so I switched...
  24. Replies
    10
    Views
    2,408

    What brand and model # of motorized actuator?

    What brand and model # of motorized actuator?
  25. Replies
    10
    Views
    2,408

    The Honeywell (Sparco) zone valve actuators are...

    The Honeywell (Sparco) zone valve actuators are failing in the open position (always on) and some of them have the plastic head separating from the brass mounting plate.