    Are the condensing units microchannel?I am going...

    Are the condensing units microchannel?I am going to install a few furnaces and see i do like the condensate trap setup on them compared to the nordyne ones getting plugged all the time.
  2. Replies
    4
    Views
    287

    LENNOX MERIT SERIES

    Any feedback on the lennox merit series? i have been looking into a lower end line which still has a branded name on it i know its an air-flo unit,i really cant go with payne,goodman ect as most of...
  3. Thread: FIRST HEAT PUMP

    by splus
    Replies
    1
    Views
    307

    FIRST HEAT PUMP

    Go to help a good friend do a startup on a heatup system today and when i was configuring the stat there was no outdoor sensor which i know is an issue.There is a honeywell th8320u1008 there,after...
  4. Replies
    9
    Views
    725

    80% sidewall venting

    Was on a call yesterday for a water heater changeout and the homeowner asks me to change the filter a quick look in the attic and there is a 2 year old 80% forced air funace sidewall vented with...
  5. Replies
    6
    Views
    1,025

    I did take all the hoses off and made sure...

    I did take all the hoses off and made sure nothing was inside them,the furnace did cycle two times and then three days later i have the same pressure switch error.
  6. Replies
    6
    Views
    1,025

    Nordyne pressure switch ordeal

    I started a a/c install 3 days ago furnace is a nordyne kg7tc 2-stage that was installed 3 years ago with no issues.While do the low voltage wiring with new stat i deside to start furnace and check...
  7. Replies
    24
    Views
    1,734

    its a microchannel coil in the air handler?there...

    its a microchannel coil in the air handler?there is a charging chart on the cover of the outdoor unit use that.i have had some issues with charging these but when you get it right you will fine and...
  8. Replies
    3
    Views
    396

    i figured as much and its 7/8 after that to the...

    i figured as much and its 7/8 after that to the coil
  9. Replies
    3
    Views
    396

    Multiple size line set on unit

    Did a pm on a trane system older 4 ton txc coil no txv and a 3.5 ton r-410 4ttb outdoor.the line set was just under 50 feet at the coil its 7/8 suction but the last 8 feet to the condensing unit was...
  10. Replies
    14
    Views
    893

    Thanks for all the good info,i am running into...

    Thanks for all the good info,i am running into alot of systems that the airflow is either way to high or set on low speed and with days of 90 degrees an above a system not set up right on...
  11. Replies
    14
    Views
    893

    Airflow and system capacity

    So if i have a 2 ton split system r410 with 700 cfm across the coil system charged correct with a 18 degree temp drop across the coil and i adjust airflow to 900 cfm adjust charge and have a 16...
  12. Replies
    18
    Views
    1,158

    This is a straight cool system,the customer...

    This is a straight cool system,the customer called after having a few days to think about it and said they understand this is a roll of the dice.another point i need to bring up is the outdoor unit...
  13. Replies
    18
    Views
    1,158

    according to the paperwork that came with the...

    according to the paperwork that came with the coil it uses the same txv for 2 thru 3 ton coils,its a aspen slab coil and the customer called and is willing to try and i mean try what ever i think i...
  14. Replies
    31
    Views
    2,330

    Is the coil a new c7 microchannel cased coil and...

    Is the coil a new c7 microchannel cased coil and if so did you add a txv or use the piston that came with the coil?if its a piston is it the correct size as i have a few of these out there and in the...
  15. Replies
    18
    Views
    1,158

    pressure dropped 4psi air temp only dropped 1...

    pressure dropped 4psi air temp only dropped 1 degree though
  16. Replies
    18
    Views
    1,158

    They totaly understand i am only going to offer...

    They totaly understand i am only going to offer maybe something that might work and it will be in writing/also i do see alot of systems around here with a 1/2 ton larger coil.
  17. Replies
    18
    Views
    1,158

    i put airflow on low and adjusted the charge that...

    i put airflow on low and adjusted the charge that was my first move
  18. Replies
    18
    Views
    1,158

    i am leaning towards a coil change,it cools to 74...

    i am leaning towards a coil change,it cools to 74 degrees at an 83 degree and under outdoor temp so i just need a little more cooling.
  19. Replies
    18
    Views
    1,158

    Nope its a 2 ton condensing unit and 2 ton ac coil

    Nope its a 2 ton condensing unit and 2 ton ac coil
  20. Replies
    18
    Views
    1,158

    Changing coil on undersized system

    I was brought in as a second set of eyes on this one.Got a 2 ton r410 txv system 10 degree s/c 13 degree s/h with a 15-16 degree temp drop across coil.the system will only cool down to 74 degrees on...
  21. Thread: Aspen flowrater

    by splus
    Replies
    7
    Views
    369

    The physical size is not right,i do remember...

    The physical size is not right,i do remember seeing a lennox coil with a different style orifice.
  22. Thread: Aspen flowrater

    by splus
    Replies
    7
    Views
    369

    That orifice sure looks like all the standard...

    That orifice sure looks like all the standard ones i have is it in fact bigger than that
  23. Thread: Aspen flowrater

    by splus
    Replies
    7
    Views
    369

    Aspen flowrater

    Does anyone have a part number for a aspen flowrater orifice?i need around a .59 its for a 2.5 ton coil the standard orifice i have are all to small and maybe a vendor i can get one
  24. Replies
    36
    Views
    2,108

    How much pressure should be in the bulb i broke...

    How much pressure should be in the bulb i broke it off on the bad one and there was very pressure,and i do not like the ones with the copper eq line stainless ones from danfoss seem more trustworthy
  25. Replies
    36
    Views
    2,108

    This was a parker valve and i do agree i am...

    This was a parker valve and i do agree i am seeing more txv issues recently also.