  1. Replies
    23
    Views
    1,386

    Ben a long time I last posted , just wanted to...

    Ben a long time I last posted , just wanted to add my 2 cents. I all ways clean flame sensor at heat check out to prevent possible go back. Most of the older Rheem boards just needed 1.5 microamps...
  2. your probably moveing to much return air threw...

    your probably moveing to much return air threw grill , if blower cfm right you need larger or more return air grill or go with grill with larger opening on loovers.
  3. Replies
    9
    Views
    1,158

    If every thing is good with pilot flame check...

    If every thing is good with pilot flame check millivolts on thermopile disconnected-without
    load then connect and read millivolts with a load. It may be the safety part of the valve bad.
  4. Replies
    2
    Views
    394

    dont have my blue book with me to look it up but...

    dont have my blue book with me to look it up but if you get all the numbers off compressor and around the age then you could tell.
  5. Replies
    67
    Views
    3,963

    I wonder where the leak was? a rusted out drier...

    I wonder where the leak was? a rusted out drier ok replace it, but a leak in a evaporator
    coil thats 18 years old, unless its a distributer tube that rubbed on a turn bend a good clean braze , but a...
  6. Replies
    11
    Views
    5,069

    Hey! check out what btu capacity those...

    Hey! check out what btu capacity those compressors have on them, at least on the last version of the GSC you may be shocked.
  7. Get a heat load done on house so you know exactly...

    Get a heat load done on house so you know exactly what you need , before you get a a/c contractor to install it for you. Its not ilegal to install a 10 seer condenser just smarter to install new 13 +...
  8. Replies
    40
    Views
    2,817

    If ducts & system sized right most manufactures...

    If ducts & system sized right most manufactures count on running 1st stage longer to dehum but that dosnt allways work. T/stats that have d-hum opthion use an average of temps to display rh% and set...
  9. Replies
    8
    Views
    1,084

    you said solenoid in compressor 2 stage. If your...

    you said solenoid in compressor 2 stage. If your talking about the rectifier-solenoid on a scroll compressor it self verify, disconnect both 24 volt wires to it & see if it over amps or blows fuse...
  10. Thread: Hot on upper floor

    by acg
    Replies
    72
    Views
    5,325

    Find an A/C contractor that can size all your...

    Find an A/C contractor that can size all your supply and return ducts right for the upstairs and if your A/C system is sized right, and you have enough room at plenum also get a 2 zone damper system...
  11. Thread: filter grille size

    by acg
    Replies
    4
    Views
    674

    did you mean the discharge plenum ???

    did you mean the discharge plenum ???
  12. Thread: filter grille size

    by acg
    Replies
    4
    Views
    674

    residential around 160 sq " per ton for a filter...

    residential around 160 sq " per ton for a filter return grill, 80 sq" for a larger loovered one.
  13. Replies
    20
    Views
    1,255

    Heat load, need exp-tech to recheck for proper...

    Heat load, need exp-tech to recheck for proper refrigerant charge,air flow, air leaks,
    t/stat wireing and configuration. Also install humidistat to control the D-hum better.
  14. Replies
    19
    Views
    1,020

    The Lennox solar kit only produces 190 watts on a...

    The Lennox solar kit only produces 190 watts on a good sunny day. Its expensive to install solar power for your home , but I hear theres a device comeing out this year thats installed on new or...
  15. Thread: RUN CAPACITORS

    by acg
    Replies
    3
    Views
    491

    RUN CAPACITORS

    IM shure every ones had problems with run caps on all brands of equipment.
    Ive tried other replacements Global , mars etc. those brands continue to go out , Done ok with Turbo run caps. Can anyone...
  16. Replies
    415
    Views
    19,245

    I dont know what your average temp or load...

    I dont know what your average temp or load calculation is in your area. But if all has been done on my first statement then give some more feed back.
  17. Replies
    415
    Views
    19,245

    If heat load was done and correct find out if...

    If heat load was done and correct find out if they figured it just for 20*diff / ave 100* fig 80*/ 20* difference.
    If a/c operating correct & the right tonage.Concentrate on a flow hood test for the...
  18. I went to visit my Dad in Hewitt / WACO TX. and...

    I went to visit my Dad in Hewitt / WACO TX. and looked at the system that had just been installed. The primary drain line wasnt insullated (thats not to complain about)but the vent pipe was two...
  19. Replies
    18
    Views
    1,564

    I would call a new a/c company just to do a good...

    I would call a new a/c company just to do a good electronic leak test of your system, and believe it or not
    I had a customer that had a R#22 leak problem & come to find out the neighbors kid was...
  20. Replies
    4
    Views
    1,448

    I dont have # handy it should be around 41,000...

    I dont have # handy it should be around 41,000 BTU
    3.5 ton 51 week of 1990
  21. Replies
    2
    Views
    971

    by code some inspectors would like to see a...

    by code some inspectors would like to see a return 10'from a fire place or wood burning stove.
  22. Replies
    21
    Views
    3,404

    Sorry drk I just heard the brush method didnt do...

    Sorry drk I just heard the brush method didnt do so well
    thats all.
  23. Replies
    21
    Views
    3,404

    Duct cleaning is good.If there is a mold problem...

    Duct cleaning is good.If there is a mold problem thers no cleaning to fix it ,repair air leaks,cut out the infected area and rebuild and or replace ducting.Most brush types of cleaning doesnt do so...
  24. Replies
    21
    Views
    3,404

    Without a doubt the very best method in the USA...

    Without a doubt the very best method in the USA does a lot
    better than the brush method. Call (210)732-9772 talk to Lee Haun you will profit from this Info.
  25. Thread: Need serious help

    by acg
    Replies
    23
    Views
    1,999

    I guess your right! why dont you just adapt a...

    I guess your right! why dont you just adapt a window a/c to
    use in your enclosure with a humidistat/stepdown tranaformer 24v to a 24v relay to drop fan speed down to
    help d-hum.