Search:
Type: Posts; User: df
Search: Search took 0.01 seconds.
-
09-16-2012, 06:11 PM
Thread: Boiler: Viessmann Vitodens 100-W Questions
by df- Replies
- 2
- Views
- 696
This is the Ask Our Pro's forum. In order to post...
This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
-
09-16-2012, 06:06 PM
- Replies
- 24
- Views
- 3,131
Nice
Nice, neat work. Beautiful piping. Are you using CPVC for the combustion air intake as well? It is hard to tell from the photo. - DF
-
07-12-2012, 06:38 PM
Thread: Ignition module bandit
by df- Replies
- 11
- Views
- 1,994
Lazy
How lazy can you get! C'mon, 2 screws. - DF
-
07-12-2012, 06:27 PM
Thread: Mitsubishi Ductless Split
by df- Replies
- 24
- Views
- 6,041
Mits
Nice, neat work. I have only used wind baffles for low ambient cooling applications (server rooms, computer rooms, etc.). -DF
-
07-12-2012, 06:16 PM
Thread: Radiant floor installation
by df- Replies
- 17
- Views
- 2,791
Nice
Nice looking work. Keep rolling with the radiant! - DF
-
06-18-2004, 05:24 PM
Thread: Installed by Plumbers
by df- Replies
- 56
- Views
- 9,241
The Maxitrol is installed vertically. Is that...
The Maxitrol is installed vertically. Is that teflon tape on the gas pipe? Otherwise, looks better than most I see. -DF
-
06-16-2004, 02:05 PM
Thread: Carrier Heat Exch.
by df- Replies
- 19
- Views
- 4,416
Answers: Coolwhip, the gas pressure was adjusted...
Answers: Coolwhip, the gas pressure was adjusted after the heat exchanger was replaced. Unfortunately, I see alot of the tube style heat exchangers split along the weld. They are not usually as...
-
06-16-2004, 09:17 AM
Thread: Carrier Heat Exch.
by df- Replies
- 19
- Views
- 4,416
LOL!!! That's one of my techs, Vince. I guess...
LOL!!! That's one of my techs, Vince. I guess he was just trying to stay warm! :0 -DF
-
06-16-2004, 08:46 AM
Thread: Carrier Heat Exch.
by df- Replies
- 19
- Views
- 4,416
http://ww2.imagewiz.net/images/hvac/88929_Carrier1...
http://ww2.imagewiz.net/images/hvac/88929_Carrier1.JPG
http://ww2.imagewiz.net/images/hvac/88930_Carrier2.JPG
http://ww2.imagewiz.net/images/hvac/88931_Carrier3.JPG
... -
06-13-2004, 01:31 PM
Thread: Nice attic job!!
by df- Replies
- 18
- Views
- 4,268
http://ww2.imagewiz.net/images/hvac/87731_Simon1.j...
http://ww2.imagewiz.net/images/hvac/87731_Simon1.jpg
http://ww2.imagewiz.net/images/hvac/87732_Simon2.jpg
Here are the "after" pics. We ripped out all of the flex and replaced it with... -
Tank
Thanks for the comments. The tank is a Viessmann Vitocell 300 -DF
-
http://ww2.imagewiz.net/images/hvac/84213_Roberts1...
http://ww2.imagewiz.net/images/hvac/84213_Roberts1.JPG
http://ww2.imagewiz.net/images/hvac/84214_Roberts8.JPG
http://ww2.imagewiz.net/images/hvac/84215_Roberts3.JPG
... -
06-05-2004, 04:48 PM
Thread: Nice attic job!!
by df- Replies
- 18
- Views
- 4,268
Most of my work is in the Arlington, NW DC,...
Most of my work is in the Arlington, NW DC, Bethesda, Chevy Chase area. -DF
-
06-05-2004, 12:15 PM
Thread: Nice attic job!!
by df- Replies
- 18
- Views
- 4,268
The radiators are staying but the boiler will be...
The radiators are staying but the boiler will be replaced with a Burnham or Viessmann (ho has not decided). Basement system is a 13 SEER Carrier w/ var. spd A/H and sheet metal duct system (no...
-
06-05-2004, 09:14 AM
Thread: Nice attic job!!
by df- Replies
- 18
- Views
- 4,268
Flex duct
You guessed it - the rats got to the flex. The house sat vacant for a little over a year and the rats overran the place. The new owner is doing a good job remodeling the entire house in a very nice...
-
06-04-2004, 06:09 PM
Thread: Nice attic job!!
by df- Replies
- 18
- Views
- 4,268
http://ww2.imagewiz.net/images/hvac/83909_DSC00323...
http://ww2.imagewiz.net/images/hvac/83909_DSC00323.JPG
http://ww2.imagewiz.net/images/hvac/83910_DSC00325.JPG
http://ww2.imagewiz.net/images/hvac/83911_DSC00320.JPG...
Results 1 to 16 of 16

