  1. Replies
    21
    Views
    2,544

    Yes it is 3 phase, What i think happen is that...

    Yes it is 3 phase, What i think happen is that flooded the compressor on start up and cooked the compressor bearings, i am going to pump it down. realse the pressure and open the head. I wish it was...
  2. Replies
    21
    Views
    2,544

    Compressor has been down for a couple of 4 months,

    Compressor has been down for a couple of 4 months,
  3. Replies
    21
    Views
    2,544

    Wired to specs, Contactor chatters a little but...

    Wired to specs, Contactor chatters a little but its pulled in, got voltage out of the contactor and into the overload and the compressror windings, Compressor trys to start and heats up...
  4. Replies
    21
    Views
    2,544

    Had voltage going to the compressor and ohm out...

    Had voltage going to the compressor and ohm out the compressor windings seem good.... even when compressor is off the block warms up...
  5. Replies
    21
    Views
    2,544

    what kinda of info ?

    what kinda of info ?
  6. Replies
    21
    Views
    2,544

    Compressor overheating and shut down???

    system had a leak fixed the leak and charged unit up. At first the compressor turn on and off, Then i opened the main disconnect and restarted it, Compressor turned on and was making a funny noise...
  7. Replies
    11
    Views
    2,328

    Thanks for all your inputs

    Thanks for all your inputs
  8. Replies
    11
    Views
    2,328

    Thank you, Your right it does have a reciever...

    Thank you,

    Your right it does have a reciever and a Headmaster condenser flooding control,

    So what would be the best way to test for SC in this system, As we will do a PM later, When checking...
  9. Replies
    11
    Views
    2,328

    Thanks, Yea we had a shut down request, found a...

    Thanks, Yea we had a shut down request, found a leak in the evap. I replaced the evap, i charged the unit and wanted to know the correct method on charging the unit with a hot gas bypass line and...
  10. Replies
    11
    Views
    2,328

    Subcooling with a hot gas bypass?

    When taking your subcooling reading with a hot gas bypass. Do you close the hot gas bypass valve and take your readings or leave it open? I am working on a cold room which is bascically a walk in...
  11. This is cool... from what your diagram shows me...

    This is cool... from what your diagram shows me is that you have a primary chilled loop going through your chillers and secondary feeding your storage tank and then pumped to your loads AHUs etc....
  12. Replies
    265
    Views
    28,110

    [QUOTE=bunny;11693012] Thank you, Is...

    Thank you,
    Is there any way that i can test the system out right now with low ambeint temps to verify that it works?
  13. Replies
    265
    Views
    28,110

    [QUOTE=dirtyboy103us;11687362]welcome home rocket...

    [QUOTE=dirtyboy103us;11687362]welcome home rocket we have been waiting


    you should have put this in a new thread this is very old and some very smart guys here might not have been around back...
  14. Replies
    265
    Views
    28,110

    SUBCOOLING? i read the first pages of this...

    SUBCOOLING? i read the first pages of this thread, its seems to be a hot topic.

    So i impose this question, I want to charge a cold room, Name plate has no info on it about amount the unit...
  15. Replies
    9
    Views
    2,215

    NICE!!!!

    NICE!!!!
  16. Thread: Newibe

    by rocket600
    Replies
    1
    Views
    458

    Newibe

    New to this Forum hope to learn and help others on trouble shooting HVAC!!!
Results 1 to 16 of 16