  1. It has been found that the bubble wrap will cause...

    It has been found that the bubble wrap will cause sweating on ducts, so here in N.C. it is not approved, other products you must make sure they are approved for ducts, armacell foam?? I do not know...
  2. Thread: Tempstar

    by Keith Lohr
    Replies
    10
    Views
    1,431

    check with the tempstar supplier, most that I...

    check with the tempstar supplier, most that I have installed in the past the conversion instructions said to take the tubulators out, but check first, they warp because of the heat produced from lp...
  3. Replies
    8
    Views
    812

    Ducane is okay, what possibly may be happening...

    Ducane is okay, what possibly may be happening and I have not seen it in a while is on sone brands when the furnace stops the blower momentarily reverses, this may not be the case but would be worth...
  4. Why don't you let the computer fix it for...

    Why don't you let the computer fix it for you....... any one who half way knows anything about hvac and it sounds like your computerized contractor does not, knows that the heat does not perform as...
  5. Replies
    9
    Views
    5,258

    Is the gas line the corrugated flexible line? I...

    Is the gas line the corrugated flexible line? I bet it is, and the small lines for some reason act as a moose call. Take the line loose and blow through it, i bet it makes the noise, if so replace...
  6. Replies
    2
    Views
    1,553

    For the last several years when standing behind...

    For the last several years when standing behind the equipment with you and the duct openings facing the house supply is on the right and return on left.
  7. Replies
    5
    Views
    830

    I still beg the differ, here in N.C. we need no...

    I still beg the differ, here in N.C. we need no humidity per say in the summer it is to high as it is. The whole principal of cooling is humidity removal.
  8. I live down the road from Raleigh the heat pump...

    I live down the road from Raleigh the heat pump will work fine , dual fuel will work but alot of people on this site do not realize that you are in a mostly gas pak or package unit market due to the...
  9. Replies
    5
    Views
    830

    I just do not see the since in usuing the...

    I just do not see the since in usuing the variable speed for humidity control. Wait to you have to replace that motor. With the blower still running after the outdoor unit cuts off you will continue...
  10. most likely the mold is on the outer jacket of...

    most likely the mold is on the outer jacket of the olds insulation, not in the fibreglass, caused by sweating over the years, have old insulation removed, seal the duct and re wrap with the newer...
  11. Replies
    15
    Views
    2,231

    How about suction pressure in the heat mode equal...

    How about suction pressure in the heat mode equal to outdoor temp. for a close charge. Anyone heard of that one before? How about amp draw? Anyone heard of that either ? i have always heard that...
  12. Replies
    57
    Views
    30,192

    I have ben selling both for a long time, Amana...

    I have ben selling both for a long time, Amana has pretty much been in Tenn., Goodman in Texas. Amana has the lowest heat exchanger failure % I do believe on the market. Amana technology on their...