  1. Replies
    52
    Views
    3,230

    This has to be some kind of parody of A/C...

    This has to be some kind of parody of A/C service. It can't be real!
  2. Replies
    22
    Views
    2,666

    [QUOTE=nick muniz;17892161]I don't see any...

    [QUOTE=nick muniz;17892161]I don't see any terminals? Sup?

    I take it you don't like to pay more at JS than other supply houses like moi, I ask for parts and am told they will come in next week...
  3. Thread: LOL

    by cws110
    Replies
    3
    Views
    770

    Around here there is almost always somebody on...

    Around here there is almost always somebody on Craigslist offering a working fridge for free- and some look a lot nicer than that one was before the redneck repair.
  4. Replies
    14
    Views
    2,286

    I think that around here it is code that the...

    I think that around here it is code that the dryer vent must be behind the cond unit-from as many as we see that way. It does make it nicer to work a heat pump condenser in winter when the dryer is...
  5. In fairness, I have seen heat strips that hadn't...

    In fairness, I have seen heat strips that hadn't been working for whatever reason for a few years on a properly maintained unit that didn't look much better. It looks like the other bank was working,...
  6. Replies
    50
    Views
    5,841

    Looking at it again, it must be a reflection on...

    Looking at it again, it must be a reflection on that shiny vent pipe.
  7. Replies
    50
    Views
    5,841

    What is that copper looking pipe running...

    What is that copper looking pipe running alongside the vent pipe and looks to be ending right behind the gas shutoff valve?
  8. Replies
    11
    Views
    1,599

    It is hard to tell in the picture. They both look...

    It is hard to tell in the picture. They both look slightly out of level, but in opposite directions. I would think that if you were sloping it to drain that you would want it to drain away from the...
  9. Replies
    18
    Views
    3,269

    But it sure doesn't cost much to run in the...

    But it sure doesn't cost much to run in the summer. I guess it does cool a little, circulating somewhat cooler basement air through the house. I imagine the lack of refrigerant lines going to the AH...
  10. Would have really been funny if the blower motor...

    Would have really been funny if the blower motor turned out to good and the problem was somehting else
  11. Thread: Nive

    by cws110
    Replies
    8
    Views
    1,105

    I have actually seen quite a few electric WH's...

    I have actually seen quite a few electric WH's next to, or at least close to, gas furnaces. Don't understand that either. But I did see one even better-- an air handler right next to a gas WH. The...
  12. Replies
    10
    Views
    1,377

    Never seen a compressor--scroll or recip-- with...

    Never seen a compressor--scroll or recip-- with the suction line that low. Doesn't look like the compressor could hold but a few ounces of oil.
  13. I agree about the cheap pull out disconnects. I...

    I agree about the cheap pull out disconnects. I have pulled them out and one if the contacts breaks loose from the handle and stays in- especially the ones that look like a copper single edged razor...
  14. Replies
    23
    Views
    3,085

    I looked at a house in Alamogordo--where I intend...

    I looked at a house in Alamogordo--where I intend to move when I retire-the roof mounted swamp cooler had been upgraded to a gaspac and it had that junk teed off from somewhere --maybe right at the...
  15. Replies
    18
    Views
    2,040

    The heat exchangers and inducers were the same on...

    The heat exchangers and inducers were the same on pilot or HSI Only difference was gas valve , board and ignitor or pilot and the little funnel over the pilot
  16. Replies
    18
    Views
    2,040

    Hard to tell from the pictures but are you sure...

    Hard to tell from the pictures but are you sure it was converted? Those were available with pilots as well as HSI models. The pilot ones had a little funnel looking deal over them that went into a...
  17. Replies
    6
    Views
    1,451

    I am going to invent some kind of pump that fits...

    I am going to invent some kind of pump that fits into that black plastic box-- then I will be rich and won't have to work anymore.
  18. Replies
    26
    Views
    3,048

    The first screwup was one thing, but to come back...

    The first screwup was one thing, but to come back and make it even(possibly) worse?? Nowthat is mind boggling.
  19. Thread: New Boots

    by cws110
    Replies
    15
    Views
    1,846

    I wouldn't have gone in there-- period!

    I wouldn't have gone in there-- period!
  20. Replies
    9
    Views
    1,363

    The same ad is here in San Antonio too. Goodman...

    The same ad is here in San Antonio too. Goodman has said that there is no warranty on units purchased over the internet for a lot longer than a year-- and it is said almost exactly in those words....
  21. Replies
    12
    Views
    1,139

    Wwe are required to insulate the drain lines...

    Wwe are required to insulate the drain lines here. Nice job though!
  22. Thread: flue pipe??

    by cws110
    Replies
    19
    Views
    2,218

    Is that the fan/limit switch next to the ref...

    Is that the fan/limit switch next to the ref lines in the picture of the old system? New one looks nice too. Did you re-install the same coil or replace it too. That old furnace was probably as I am!
  23. Replies
    16
    Views
    2,623

    Nope-- Stevie Wonder

    Nope-- Stevie Wonder
  24. Replies
    15
    Views
    2,172

    Looks like a RAKA from 1993 I think that was...

    Looks like a RAKA from 1993 I think that was the first year they went back to that design after the cubes, and I am pretty sure they went to scroll in all single phase the next year.
  25. Replies
    15
    Views
    2,172

    Isn't that the remains of the capacitor laying...

    Isn't that the remains of the capacitor laying there beside the compressor? So replace the contactor and cap and they are good to go--maybe.