  1. Replies
    10
    Views
    210

    PTECs can be loaded and edited using Insight 3.13...

    PTECs can be loaded and edited using Insight 3.13 before that it took a combination of files and a command line tool. They integrated the PPCL stuff into 3.13. I don't think Desigo CC has the...
  2. Replies
    10
    Views
    210

    You can use Terminal Emulation to do it. It is...

    You can use Terminal Emulation to do it. It is pain. You can also have Siemens install the webserver in the PXCs. This is free and is what installs the Apogee Editors. You can do everything but...
  3. Replies
    10
    Views
    210

    No idea. I do know that whenever I load it up on...

    No idea. I do know that whenever I load it up on my laptop it my RAM usage immediately goes from 2-3 GB to about 12 GB. And it runs like piss on the Core i5 that I have.
  4. Replies
    10
    Views
    210

    If it is South America you should have the choice...

    If it is South America you should have the choice of either. Desigo Insight is mostly a European product but can be used in different areas of the world. If it is a new installation you will probably...
  5. Replies
    10
    Views
    210

    I am assuming you are US based and you mean...

    I am assuming you are US based and you mean Desigo CC otherwise in the rest of the world they call Insight Desigo. If you are using Desigo CC graphics are created using the Desigo CC program, but you...
  6. BACnet is becoming the industry standard for the...

    BACnet is becoming the industry standard for the most part. Siemens is pushing you that way because they never did LON very well and haven't pursued the protocol since the last iteration of their...
  7. Replies
    6
    Views
    216

    Yes with that option you will always output 20%...

    Yes with that option you will always output 20% even though on CCT and in Metasys it will show 0%. The hardware value below the output value show the actual value of the output.
  8. Replies
    3
    Views
    184

    From the Manual: This module is designed for the...

    From the Manual:
    This module is designed for the sequencing the dehumidification process. While dehumidifying, the dehumidification
    devices are controlled based on the return or zone air relative...
  9. Replies
    6
    Views
    216

    There are 2 ways to do this using CCT. The...

    There are 2 ways to do this using CCT. The easiest way is to go to the output and under details change the Hardware minimum out value to 20% instead of 0. This will force the controller to output 20%...
  10. Replies
    5
    Views
    238

    The interstage delay on and off timers prevent...

    The interstage delay on and off timers prevent the next stage from energizing or de-energizing until the interstage timer has expired. The interstage on timer for Stage 1 controls the elapsed time...
  11. Replies
    5
    Views
    238

    The interstage delays dictate how long the BO...

    The interstage delays dictate how long the BO will go before activating or deactivating after sequencing. An example if you have an interstage on delay of 10 minutes and there is one chiller running...
  12. You can assign relays to the groups. When you map...

    You can assign relays to the groups. When you map out the points all you get is the groups. So I could have Relay 5, 7, and 8 all mapped to group 1. BO 1 on the N2 side would turn on group 1 turning...
  13. There will probably not be a default point map...

    There will probably not be a default point map for the Triatek panel. Those panels are set up using LPPK software and can be done in a multitude of ways. The only points you can get out of it are BOs...
  14. Replies
    2
    Views
    290

    Yes, the space temp sharing is done in the NAE....

    Yes, the space temp sharing is done in the NAE. On the NAE you will either have a global share for each of the space temps or one or more LCT processes to do the sharing. When you release the...
  15. I assume that you have tried to force stroke the...

    I assume that you have tried to force stroke the valve from Insight/DesigoCC or WCIS if you have it. You can try cycling power to see if the valve will stroke. Other than that maybe clearing the...
  16. Replies
    6
    Views
    345

    The program files? They are just text based i use...

    The program files? They are just text based i use notepad.
  17. Replies
    33
    Views
    2,099

    For the BACnet side of the Talon line it is just...

    For the BACnet side of the Talon line it is just the same as what Siemens itself sells. PXC16,24,36s and PXCMs with TX/IO modules. From talking to a trainer earlier this week Talon View is basically...
  18. Replies
    2
    Views
    196

    Which documentation are you looking at? Total is...

    Which documentation are you looking at? Total is supported on BACnet points as of the Rev 6 manual that I have.
  19. Replies
    8
    Views
    455

    But it has to be mentioned that BACnet/IP was not...

    But it has to be mentioned that BACnet/IP was not fully functional at the revision that the NAEs are at. They didn't become fully BACnet compliant until 3.0 and I believe fully BTL Certified until...
  20. Replies
    5
    Views
    250

    I usually set it for 127. It should default to...

    I usually set it for 127. It should default to 127 but if its been changed it should be changed back.
  21. Replies
    5
    Views
    250

    Other than checking all of the BACnet settings in...

    Other than checking all of the BACnet settings in BACstac and the BLN not much there. Do you have autodiscover turned on for the BACnet BLN? If so if the PTEC is setup properly and you do send a...
  22. Replies
    3
    Views
    201

    You must log into the panel with a high level...

    You must log into the panel with a high level user. If it is an older panel high, high usually works. Just HMI without login gives you the display only option.
  23. Replies
    3
    Views
    201

    You can HMI into the panel and the first options...

    You can HMI into the panel and the first options is Time from there you can change the date and time.

    If you have access to the Insight Server in System Profile you can go into the panel and...
  24. Replies
    5
    Views
    250

    Is the PTEC setup to be a master? If the TECs...

    Is the PTEC setup to be a master? If the TECs aren't setup as master the PXCM won't act as a BACnet router and route the PTEC out to the IP network side of the controller. A lot of jobs have the TECs...
  25. Replies
    6
    Views
    375

    http://www.tsi.com/Airborne-Particle-Counters/ ...

    http://www.tsi.com/Airborne-Particle-Counters/

    Give them a call didn't look too much into options but I'm sure they have something.
  26. Replies
    3
    Views
    219

    http://cgproducts.johnsoncontrols.com/MET_PDF/6932...

    http://cgproducts.johnsoncontrols.com/MET_PDF/693205.pdf?x=85#xml=http://cgproducts.johnsoncontrols.com/search_lit.aspx?cmd=pdfhits&DocId=7484&Index=C%3a%5cinetpub%5cwwwroot%5c72%2e3%2e145%2e66%5cquic...
  27. Replies
    3
    Views
    219

    http://cgproducts.johnsoncontrols.com/MET_PDF/6893...

    http://cgproducts.johnsoncontrols.com/MET_PDF/6893100.PDF?x=85#xml=http://cgproducts.johnsoncontrols.com/search_lit.aspx?cmd=pdfhits&DocId=7477&Index=C%3a%5cinetpub%5cwwwroot%5c72%2e3%2e145%2e66%5cqui...
  28. Replies
    8
    Views
    455

    I would say that you probably can't use the FX...

    I would say that you probably can't use the FX Server and NAEs. From what I know of the way NAEs talk JCI would have had to modify the FX Server code to allow for the communication. Not saying that...
  29. Replies
    22
    Views
    3,180

    You have mail.

    You have mail.
  30. Replies
    22
    Views
    3,180

    You must have email in your profile for any help...

    You must have email in your profile for any help to be given.
  31. Replies
    1
    Views
    198

    You have mail.

    You have mail.
  32. The webstart switch usually doesn't work with 64...

    The webstart switch usually doesn't work with 64 bit. The problem is where Windows stores the java and where the webstart tries to launch it from. This will work with 32 bit and different versions of...
  33. Thread: HVAC Pro

    by NickDeal
    Replies
    36
    Views
    1,898

    VMs are basically another machine running along...

    VMs are basically another machine running along side the host machine. It uses the same resources as the host and forces the host to share. This is not so bad if you have a decent machine with a...
  34. Thread: HVAC Pro

    by NickDeal
    Replies
    36
    Views
    1,898

    I've used the Microsoft XP mode. If you have a...

    I've used the Microsoft XP mode. If you have a Pro version of Windows 7 you get it included. I run all the old JCI stuff and most of the new stuff in it.
  35. Replies
    21
    Views
    1,395

    That is a new level of awesome. Haven't seen one...

    That is a new level of awesome. Haven't seen one like that yet.
  36. Replies
    21
    Views
    1,395

    I don't think it is all the Techs fault. I know...

    I don't think it is all the Techs fault. I know that for stand alone controllers they could care less, but for MSTP trunks they have to have unique instance numbers. JCI makes it hard to do BACnet...
  37. Replies
    3
    Views
    294

    The apps come from the ABCS website. Look at this...

    The apps come from the ABCS website. Look at this post from a few years ago.
    http://hvac-talk.com/vbb/showthread.php?519462-Fx-Builder-Express-Standard-Apps
  38. Replies
    21
    Views
    1,395

    NAEs and the ADX/ADS use secure SOAP connections...

    NAEs and the ADX/ADS use secure SOAP connections to talk between each other. Even if you make the site a BACnet site they still use SOAP not BACnet. More secure but not proprietary. You couldn't...
  39. Something you would probably never find. JCI's...

    Something you would probably never find. JCI's FSC documentation. Basically all of the documents generated from people calling tech support, the solutions, and various other information if needed....
  40. You can try a power cycle and see what happens....

    You can try a power cycle and see what happens. The MIG should store its database locally. The only documentation I could find about the LWC was if the address was changed by a technician to FF which...
  41. Replies
    2
    Views
    252

    Siemens doesn't have a default user name and...

    Siemens doesn't have a default user name and password. If the login that you have is an admin on the machine you can reset the siemens user password and login that way.
  42. Replies
    3
    Views
    414

    I would imagine that you could do it with Static...

    I would imagine that you could do it with Static or DHCP. Some home routers won't allow a static IP to attach to the network and you either have to add a static route in the router or enable it to...
  43. Replies
    7
    Views
    579

    What is your network infrastructure? Do you have...

    What is your network infrastructure? Do you have the GX tool or HVACPro and cables?
  44. Have you tried to discover the points with a 3rd...

    Have you tried to discover the points with a 3rd party solution like YABE?
  45. What version of NAE are you running? What BACnet...

    What version of NAE are you running? What BACnet encoding type are you trying to use?
  46. Replies
    1
    Views
    208

    At version that old you have to use IE6 and...

    At version that old you have to use IE6 and depending on the patch that is applied to the NAE either 1.3.1_15, 1.5.0_04, _06 or _11. You should probably contact your local JCI office to get them to...
  47. Replies
    1
    Views
    213

    Not sure what you mean by this, but the NIC tool...

    Not sure what you mean by this, but the NIC tool is JCI proprietary. You could try to purchase it from your local branch but it is doubtful.
  48. Replies
    24
    Views
    4,992

    You've got mail.

    You've got mail.
  49. Replies
    2
    Views
    411

    When I worked for JCI they sent me to the FEC...

    When I worked for JCI they sent me to the FEC class, DX-9100 class, and the LON class. The beginner level classes are not very useful if you have experience in the field. The only class that I got...
  50. Try this:...

    Try this: http://www.csimn.com/CSI_pages/VP4-23-mstp.html

    What system do you have? A lot of older protocols can now be translated to BACnet using a gateway so you could pull the chiller into your...
Results 1 to 50 of 192