Search:

Type: Posts; User: low pressure guy

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    10
    Views
    883

    patterson-kelly are nice units

    patterson-kelly are nice units
  2. Replies
    44
    Views
    6,454

    COMPRESSOR LIFT

    HEY GUYS, I'M LOOKING FOR A NAME OF A COMPANY THAT MAKES A DEVICE TO LIFT COMPRESSORS IN A CONDENSING UNIT WHERE THE COMPRESSORS ARE UNDER THE CONDENSING COILS . IT LOOKS LIKE TWO SHORT A-FRAMES W/...
  3. Replies
    12
    Views
    2,671

    BOILERS TO SMALL AND WHATS UP W/THE TRAP IN THE...

    BOILERS TO SMALL AND WHATS UP W/THE TRAP IN THE PVC FLUE.
  4. Replies
    39
    Views
    4,195

    WITH TOWER WATER THAT COLD ITS POSSIBLY A LOW...

    WITH TOWER WATER THAT COLD ITS POSSIBLY A LOW SIDE SURGE . RAISE UP THE TOWER WATER TEMP.
  5. I JUST REPLACED COILS IN 2 LIEBERTS . WASN'T THAT...

    I JUST REPLACED COILS IN 2 LIEBERTS . WASN'T THAT HARD. UNBRAZE PIPING , REMOVE CLIPS UNDER CONDENSATE PAN AND LIFT UP COIL AND SLIDE OUT FROM OPPOSITE END FROM COMPRESSORS. NEW COIL COMES W/ TXV'S...
  6. Replies
    10
    Views
    5,409

    CALL YOUR TRANE DEALER AND GET A '' COMFORT SITE...

    CALL YOUR TRANE DEALER AND GET A '' COMFORT SITE '' SIGN UP AND YOU CAN GET ALL THE INFO YOU NEED ANY TIME YOU WANT.
  7. Replies
    28
    Views
    2,338

    CVHE THRUST BEARING

    I WOULD LIKE TO KNOW WHAT PEOPLE THOUGHT ABOUT USING A HYDRAULIC NUT TO SET THRUST BEARINGS . DO YOU GUYS USE THEM AND DO YOU THINK ITS NEEDED . THE CHILLER I'M DOING IS A R123 CONVERTED "" C ""...
  8. Replies
    12
    Views
    2,414

    TRY LOOK AT FLOW SW THAT OMEGA ENGINEERING IN...

    TRY LOOK AT FLOW SW THAT OMEGA ENGINEERING IN STAMFORD CT. THE BODY IS MADE FROM PLASTIC AND DOESNT SWEAT AND CORRODE LIKE THE METAL ONES. ALSO THE PADDLE IS A DISC INSTEAD OF THE STRIPS
  9. Replies
    10
    Views
    1,239

    I DUG MINE OUT OF MY TRUCK . ITS A VAC-Q PART#...

    I DUG MINE OUT OF MY TRUCK . ITS A VAC-Q PART# VQ-71 . IBOUGHT IT FROM ROBERT R. HUMBERT,MFG . P.O. BOX U . MILFORD,P.A. 18337. TEL#1-570-296-8484. THATS ALL OF THE INFO I HAVE . YOU HAVE TO GET...
  10. Replies
    10
    Views
    1,239

    IF YOU WANT A REALLY GOOD GAUGE GET A DEVICE...

    IF YOU WANT A REALLY GOOD GAUGE GET A DEVICE CALLED A VAC-AN -AOL. YOU CANT GO WRONG. I THINK I SPELLED IT RIGHT.
  11. Replies
    10
    Views
    686

    Finished repair ,heat fittings and pulled steel...

    Finished repair ,heat fittings and pulled steel lines out . Silver brazed new copper into new level tank and replaced with new sensor . Worked great .
  12. Replies
    10
    Views
    686

    Hey Klove how did you fix yours.

    Hey Klove how did you fix yours.
  13. Replies
    10
    Views
    686

    I TURNED 40 CAN'T SEE AS WELL ANYMORE OR I'VE...

    I TURNED 40 CAN'T SEE AS WELL ANYMORE OR I'VE BEEN MARRIED TO LONG.
  14. Replies
    10
    Views
    686

    RTHC REFG LEAK

    WONDERING IF ANYONE HAS COME ACROSS THIS LEAK . LIQUID LEVEL SENSOR STEEL TUBING RUSTED FROM OUTSIDE IN BECAUSE OF CONENSATE BETWEEN INSULATION AND TUBING. TUBING IS BRAZED INTO STEEL FITTINGS THAT...
  15. Replies
    27
    Views
    2,403

    CVHE TEARDOWN CLEANER ?

    JUST CURRIOUS ABOUT WHAT YOU GUYS ARE USING AS A CLEANER / DEGREASER TO CLEAN SURFACES AND O-RING GROOVES ON VOLUTE CASTINGS . I FINALLY USED UP ALL OF MANY OLD VIRGINA-10 AND I DON'T LIKE THE NEW...
  16. Replies
    8
    Views
    1,689

    I WENT TO JOHNSON COURSE THAT WAS GOOD AND ALSO...

    I WENT TO JOHNSON COURSE THAT WAS GOOD AND ALSO TOOK ABB COURSE ONLINE IT ALSO WAS INFORMATIVE.
  17. Replies
    2
    Views
    531

    Rthc Rusty Pipe

    Looking For Suggestions On How I Should Go About Repairing A Leak In A Rusted Pipe On The Liquid Level Tank Piping Right Near The Evap Shell.condensation Must Have Collected Between Pipe And...
  18. Replies
    5
    Views
    817

    I Had The Same Problem. With Machine Running ,...

    I Had The Same Problem. With Machine Running , Manually Load Chiller And Watch Vane Arms To See If They Stick Or Snap Open When The Refrigerant Is Moving Though Compressor . Thats How We Found The...
  19. Replies
    63
    Views
    9,512

    Whats Up With The Glycol Tank In Front Of The...

    Whats Up With The Glycol Tank In Front Of The Electrical Panel . Is That Ok With The Code?
  20. Replies
    16
    Views
    2,392

    I Had Same Problem . After Very Long Time Of...

    I Had Same Problem . After Very Long Time Of Talking To Factory And Sale Rep . I Recovered Charge And Removed Oil Charge . Found Oil Over Charged From Factory . Oil Was Insulating Sensor . Making...
  21. Replies
    13
    Views
    1,550

    Where Are They Leaking? The Tube Itself, The...

    Where Are They Leaking? The Tube Itself, The Rolled End.
  22. Replies
    39
    Views
    4,893

    Don't Waste Yor Time With Ground Straps . Doesn't...

    Don't Waste Yor Time With Ground Straps . Doesn't Last Long Term. Need To Use Good Vfd's. Next Best Thing Is Ceramic Coated Bearings . With Cheap Drives The Sine Wave Backs Up Over Its Self And Makes...
  23. Replies
    12
    Views
    1,458

    Great Option !

    Great Option !
  24. Replies
    26
    Views
    2,113

    I had the same problem about a year ago with R11...

    I had the same problem about a year ago with R11 machine that was converted to R123 also . Machine ran for years and then loss of oil pressure problems. But when I manually ran oil pump it would...
  25. Replies
    14
    Views
    1,584

    I Believe That In The Back Of The Trane Service...

    I Believe That In The Back Of The Trane Service Manuel There Are Prints To Make Your Own Lifting Plates. I Have A Set I Made Years Ago.
Results 1 to 25 of 87