Search:

Type: Posts; User: ascj

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    6
    Views
    264

    Works fine with Honeywell Workbench

    Works fine with Honeywell Workbench
  2. Replies
    9
    Views
    665

    We have integrated tons of Reliatel Rtu's with...

    We have integrated tons of Reliatel Rtu's with comm 4. You do have both Rtu's addressed differently...yes?
  3. Replies
    4
    Views
    563

    I appreciate the links. I thought is was a...

    I appreciate the links. I thought is was a Spyder thing.

    You would think the PriPv would default to false, instead of true.
  4. Replies
    4
    Views
    563

    Bacnet Honeywell Spyders

    Been doing more offline programming of databases for jobs these days. I'm having issues with Honeywell Bacnet Spyders.

    Doing an offline discovery of data points and adding them to the...
  5. Replies
    2
    Views
    480

    Platform Application

    Ran into a Jace today, with a message I have never seen before. It repeats it every few seconds. Went through the drivers and services to see if a debug was on. I didn't see anything.

    Just...
  6. Replies
    0
    Views
    352

    Tridium Audit History

    Is there a way to customize what gets logged in the Audit History? We do some major exporting of histories on a particular and would like to omit the exporting form the audit history.
  7. Replies
    0
    Views
    345

    Trane Voyager Points

    I had a Trane Voyager points list, that I can't seem to find anymore. It listed all the points and descriptions. This was Com4/MicroControl. Anyone have a copy?
  8. Thread: Summit and Win 7

    by ascj
    Replies
    3
    Views
    417

    Thanks for the reponses. This is kinda of good...

    Thanks for the reponses. This is kinda of good in a way, since they are looking into pushing the full upgrade sooner.
  9. Replies
    11
    Views
    1,116

    The most recent Maxline CommFour Module is...

    The most recent Maxline CommFour Module is 3.7.106.6. It came out April 5, 2014.

    If you have the Maxline CommFour Driver, then it just a simple update to the module. There are no dependencies. ...
  10. Thread: Summit and Win 7

    by ascj
    Replies
    3
    Views
    417

    Summit and Win 7

    We have a customer who lost their Summit front end hard drive. It was running Windows XP. They got a new computer with Windows 7 Pro. I installed Summit on it, with no issues.

    They called Trane...
  11. Replies
    13
    Views
    1,329

    Is there anyway I could get them also?

    Is there anyway I could get them also?
  12. Replies
    6
    Views
    789

    Is nvoHeatCool ever going to HVAC_HEAT...with...

    Is nvoHeatCool ever going to HVAC_HEAT...with nviApplicMode set to HVAC_HEAT? If it isn't, then I would be double checking nviPriHeatEnable(for the DAC) and nviAuxHeatEnable(for the SCC). Remember...
  13. Replies
    35
    Views
    3,653

    I would appreciate a copy. Email in...

    I would appreciate a copy. Email in profile.....thanks.
  14. Replies
    3
    Views
    703

    If you have a Bacnet license already and want to...

    If you have a Bacnet license already and want to trend in the Jace.......then you are good to go. You don't need the Tcomm driver. The Tcomm driver is required to pull trending out of the EasyIO. ...
  15. Thread: Trane UPCM to PCG

    by ascj
    Replies
    4
    Views
    486

    I normally find it easier to just go through the...

    I normally find it easier to just go through the Inputs and open them. It's quicker then going through UPCMedit.
  16. Replies
    3
    Views
    703

    Do you need schedules and histories? EasyIO's...

    Do you need schedules and histories? EasyIO's can be brought into a Jace via Bacnet MS/TP or TCP, Modbus, or Sedona. Tcom driver gives you the most flexibility. But if price is a issue and you...
  17. Replies
    11
    Views
    1,116

    Will agree with chadtech.........this was an...

    Will agree with chadtech.........this was an issue with their 3.7.46.4 driver and earlier.

    It has been resolved......if you need the newest driver, just let me know. Also, if your module is...
  18. Replies
    9
    Views
    1,045

    What was the model of RTU? What was the actual...

    What was the model of RTU? What was the actual alarm you were seeing? Is it the VFD that is locking out? Why isn't the phase monitor shutting the unit down, first?

    My experience with Carrier...
  19. Replies
    3
    Views
    435

    I trigger it by UnOccupied to Occupied. Then...

    I trigger it by UnOccupied to Occupied. Then setup a max time and a start/stop temps.

    Here is the application I use-

    499511
  20. Replies
    6
    Views
    719

    Just curious....why the 7 Jace 700's?

    Just curious....why the 7 Jace 700's?
  21. Thread: Jace CCN Inteface

    by ascj
    Replies
    15
    Views
    1,343

    You might want to look into bringing them in...

    You might want to look into bringing them in Bacnet with a UPC Open Controller for each. Another option is a Ivu link. You are limited to 500 Bacnet points, but with just 4 chillers.....that should...
  22. Thread: Carrier Ivu

    by ascj
    Replies
    1
    Views
    391

    Carrier Ivu

    Is there a network point limit per controller?

    I have a 6400 on a Ivu 4.2, that I'm trying to fix some points. Looking at the equipment file they are all there and mapped. I download to the Ivu...
  23. Replies
    7
    Views
    1,264

    You verified you only have one broadcast...

    You verified you only have one broadcast acknowledger per buss? You verified you only have one controller per schedule broadcasting? Meaning you don't have duplicate schedule numbers being...
  24. Thread: Service tool 5

    by ascj
    Replies
    7
    Views
    873

    Sent you an email.

    Sent you an email.
  25. Replies
    5
    Views
    555

    Sent you an email.

    Sent you an email.
  26. Replies
    5
    Views
    555

    It's amazing how often they update their drivers....

    It's amazing how often they update their drivers. The newest version I have is 3.7.106.2.

    I sent a email to my connection at Maxline for the newest driver and their patch notes. But since the...
  27. Replies
    5
    Views
    555

    What version driver? What kinda of devices?

    What version driver? What kinda of devices?
  28. Replies
    25
    Views
    4,801

    360 seconds is the stroke time. Be careful with...

    360 seconds is the stroke time. Be careful with retrofit controllers......those VAV's have ends switches, which can wreck some controllers with triacs. You can add some isolation relays or add some...
  29. Thread: CCN Issue

    by ascj
    Replies
    10
    Views
    767

    My bad....yes they are Gen3. I'm changing the...

    My bad....yes they are Gen3. I'm changing the BCACK point. It just doesn't recognize the buss, element when I do a scan for broadcast acknowledgers.

    Anyway, I spent some more time with the...
  30. Thread: CCN Issue

    by ascj
    Replies
    10
    Views
    767

    No....I'm changing the controller to a broadcast...

    No....I'm changing the controller to a broadcast acknowledger......but when I do a buss scan on that buss, my service tool show nothing. I'm pretty familiar with using the Carrier service tool and...
  31. Thread: CCN Issue

    by ascj
    Replies
    10
    Views
    767

    Changes and scanning are through NSTV. No Ivu...

    Changes and scanning are through NSTV. No Ivu onsite.
  32. Thread: CCN Issue

    by ascj
    Replies
    10
    Views
    767

    CCN Issue

    I have a building, I'm trying to straighten out. They have two CCN busses. One for the first floor with 48 devices and one for the 2nd flr with 52 devices. I know I need a broadcast acknowledger...
  33. Replies
    3
    Views
    373

    JCI's default IP is 192.168.1.149. You should no...

    JCI's default IP is 192.168.1.149. You should no issues using you webs workbench......just copy the modules. The default credentials with be user- jci and password- explorer
  34. Replies
    6
    Views
    627

    No I was wrong......that is the case with...

    No I was wrong......that is the case with Voyagers/Precedents and VAV's. I was a little off kilter, last night. DaveM is correct. Sounds like your dip switches are set wrong.

    TCI Installation...
  35. Replies
    6
    Views
    627

    He didn't mention vintage........but I was...

    He didn't mention vintage........but I was assuming TCI-4 boards. Since he has the ability to change the address from the HMI's.
  36. Replies
    3
    Views
    538

    TUNCOS just offsets setpoints based on time to...

    TUNCOS just offsets setpoints based on time to next event.....its a Honeywell thing.

    We haven't done much with pneumatic VAV's with XL10's.........but I do remember John Hutchey mentioning this...
  37. Replies
    6
    Views
    627

    Not sure what literature you are looking...

    Not sure what literature you are looking at......but Intellipaks start there network working adressing at 32. So a local configured address of 1 is 32 on the Comm4 network. Voyagers and Precedents...
  38. Replies
    3
    Views
    538

    You should be fine with only writing to the...

    You should be fine with only writing to the TODEvent. They should synchronize every time the controller enters UnOccupied mode or is restarted. Also, if the controller doesn't enter UnOccupied for...
  39. Thread: WSHP DP switch

    by ascj
    Replies
    14
    Views
    1,002

    I would would curious about the specs. But 2.8...

    I would would curious about the specs. But 2.8 ft is 1.2psi.

    Still seems low.....as I said, we just did some real small McQuays(Daiken) and they were a bit higher. We did not have to proof flow...
  40. Replies
    3
    Views
    770

    That is my questions.......they only state it's a...

    That is my questions.......they only state it's a weighed parameter based on last optimized start. Just trying to figure out how it comes into play of the algorithm.

    Is there a better optimized...
  41. Thread: WSHP DP switch

    by ascj
    Replies
    14
    Views
    1,002

    Wow that is low.....I'm curious what WSHP's they...

    Wow that is low.....I'm curious what WSHP's they are. I just did a job with some tiny 7000 btu McQuay's. They were specced for 2.1 gpm which was a 5.1 ft pressure drop......so a 2.2psi drop.

    I...
  42. It's pretty simple......you have to prioritize...

    It's pretty simple......you have to prioritize your building heating. What's the best way to do it, is the question.

    It would easier if you provided a piping diagram of what you have existing. ...
  43. Replies
    3
    Views
    770

    Optimized Start/Stop

    I have been going through some of our older jobs and analyzing them. We use the Vykon OptStartStop in our scheduling. It seems some sites are working better than others. I have gone through all...
  44. Thread: LonSpec

    by ascj
    Replies
    5
    Views
    521

    I should share this....484621

    I should share this....484621
  45. Thread: LonSpec

    by ascj
    Replies
    5
    Views
    521

    I have tried big time to no gain. I bought a...

    I have tried big time to no gain. I bought a ExpressCard to PCMCIA.....then found out Lonspec doesn't play nicely with 64bit. No big deal......run it on Windows XP VM. Wait I can't find a VM...
  46. Replies
    3
    Views
    364

    We are a Honeywell rep and we have difficulties...

    We are a Honeywell rep and we have difficulties bringing them in. The way they were originally commissioned with Lonspec is different then the way the Jace is going to commission them. Yours...
  47. I would just use the newest 6.0 SpyderTool. You...

    I would just use the newest 6.0 SpyderTool. You can use it with either 3.7 or 3.8. Why not just commision with 3.8 AX with 6.0? There is no advantage to 3.7 with 5.2 with a new job. I have a one...
  48. Replies
    9
    Views
    1,157

    Awesome....thanks. That worked like a...

    Awesome....thanks. That worked like a champ......I have been messing around with this for quite some time. If I could only resolve the Lon -1 and the Bacnet 255 conversion........but I can work...
  49. Replies
    9
    Views
    1,157

    The error in the screen shot is me trying to add...

    The error in the screen shot is me trying to add a niagara proxy from a Bacnet Spyder's AV point, that has a custom enum.

    Have your ever been able to bring in any Bacnet Spyder point in as an...
  50. Replies
    9
    Views
    1,157

    So you have had luck adding custom enum to Bacnet...

    So you have had luck adding custom enum to Bacnet Spyders input/outputs? Anytime I try to use custom enums to network inputs/outputs on Bacnet spyders.....I get the following error.

    482611

    I...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards