  1. Replies
    22
    Views
    2,634

    .4 is not much,would not think that would cause...

    .4 is not much,would not think that would cause that big of an issue.I had residential unit once did the same thing take dor off light fine with the lovered door on would pop once in awhile.Come to...
  2. Replies
    19
    Views
    1,614

    My buddy was in same situation 20 years ago. Now...

    My buddy was in same situation 20 years ago. Now he he has 4 or 5 full time employees has two very nice homes and pretty much living large so I would really think about that before you throw it away.
  3. Bunch here in illinois.

    Bunch here in illinois.
  4. Thread: Rawal

    by local553
    Replies
    20
    Views
    1,548

    Hey if boss says then it,must be right lol. But...

    Hey if boss says then it,must be right lol. But the valves do work well.
  5. Replies
    38
    Views
    2,437

    School of hard knocks

    School of hard knocks
  6. Thread: subcooling

    by local553
    Replies
    35
    Views
    2,189

    High sub cool means overcharged low sub is...

    High sub cool means overcharged low sub is undercharged check,name plate or on unit it will tell you take amp draw on compresser, if you have high sub cool compressor may be gething a good work out
  7. Thread: florida work

    by local553
    Replies
    6
    Views
    773

    florida work

    Is there any florida union guys on here. Just wondering, I know that is not a big union state but thinking of moving there.
  8. Replies
    128
    Views
    23,986

    In our hall it would be a matter of time before...

    In our hall it would be a matter of time before you get caught.And when you do get caught it cost you about two grand for rehab out of your pocket and you get one strike.And if you stay clean you are...
  9. Thread: VAV problems

    by local553
    Replies
    4
    Views
    956

    tracer says it is blowing max. should I have more...

    tracer says it is blowing max. should I have more than .40 inches at transducer
  10. Thread: VAV problems

    by local553
    Replies
    4
    Views
    956

    200 to 1000 cfm if i remember right. 2 or 3...

    200 to 1000 cfm if i remember right. 2 or 3 degrees.
  11. Thread: VAV problems

    by local553
    Replies
    4
    Views
    956

    VAV problems

    Had a question about a vav box.I think i am in the right forum for this anyway got a box Trane vcef060.What it is doing is damper at 100% all the time.Sensor in room seems to be working,checked with...
  12. no vav program senser uses 7 thru 12 terminals

    no vav program senser uses 7 thru 12 terminals
  13. Replies
    45
    Views
    3,942

    If that was true we would not need humidifiers,to...

    If that was true we would not need humidifiers,to dehumidify we use some sort of heat.
  14. Lon Talk.These units were set up for trane...

    Lon Talk.These units were set up for trane controls.I had to disconect the boards because we were using program sensers.They were stand alone units. I am not a controls guy but we installed 23- 15 to...
  15. Replies
    45
    Views
    3,942

    No.

    No.
  16. yep no set rule for a restriction.I have found...

    yep no set rule for a restriction.I have found restrictions causing high head and restrictions not showing any alarming signs other than not cooling good.
  17. The new units we installed have interface boards...

    The new units we installed have interface boards ,there not hooked up to rtrm board.
  18. Replies
    43
    Views
    2,927

    Refineries make more money off the coke (dirty...

    Refineries make more money off the coke (dirty coal) than the gas.Our company does alot of work in the refinery here.They said they can make it and have it shipped for about 6 dollars a ton and sell...
  19. Replies
    6
    Views
    2,695

    Sorry,coil in supply or return if in supply take...

    Sorry,coil in supply or return if in supply take trap out don't need it.
  20. Replies
    6
    Views
    2,695

    upflow or downflow?

    upflow or downflow?
  21. Replies
    20
    Views
    2,216

    I am in central Illinois you know the state with...

    I am in central Illinois you know the state with the honest governers.
  22. Replies
    9
    Views
    3,410

    You should not have to get any type of board.That...

    You should not have to get any type of board.That rtrm board that is there will take 24 volt stat or program sensor or none program. Terminals 1 thru 5 is for non program sensor the others are for...
  23. Replies
    9
    Views
    3,410

    program sensor 7,heat,8cool and I think 6 is...

    program sensor 7,heat,8cool and I think 6 is common 12 and 13 are 24 volts. something in that order. And yes like time builder says not like y,g,etc.
  24. Thread: PEE-YEW

    by local553
    Replies
    7
    Views
    1,975

    looks like one of them is missing blower door.

    looks like one of them is missing blower door.
  25. Replies
    154
    Views
    36,811

    I'm fifty years old and already made my path and...

    I'm fifty years old and already made my path and have my career.I am making not much under what flange's guys make.I am in with a company that doe's about 70 million a year between piping and...
  26. Replies
    154
    Views
    36,811

    a lot of people do not care for unions, but after...

    a lot of people do not care for unions, but after reading a few of these posts all I can say is THANK GOD FOR UNIONS.And no just because your in union doe's not mean free ride,if your no good you be...
  27. Replies
    20
    Views
    2,216

    If your not with a strong company a few weeks of...

    If your not with a strong company a few weeks of great weather could be a problem.
  28. Thread: Trane Wreck

    by local553
    Replies
    3
    Views
    812

    they missed the service valves.

    they missed the service valves.
  29. Replies
    39
    Views
    2,381

    I think that guy was wrong for what he did to...

    I think that guy was wrong for what he did to that computor.I would have opened it up showed the girls screen saver and used a heavy turkey load.
  30. ditto; shoot them be done with it and move on.

    ditto; shoot them be done with it and move on.
  31. Replies
    60
    Views
    4,605

    Trust me the reving of compressor is fact. That...

    Trust me the reving of compressor is fact. That is the only time I ran acrossed it in 20 some years of service.No reason to lie bro just telling what I have came across.
  32. Replies
    60
    Views
    4,605

    never heard of it,fill me in.

    never heard of it,fill me in.
  33. Replies
    60
    Views
    4,605

    A unit running in vacuum for who knows how long...

    A unit running in vacuum for who knows how long and a tech comes along and dumps gas in it.
  34. Replies
    28
    Views
    3,272

    make sure phase is right,they have monitors on...

    make sure phase is right,they have monitors on them.
  35. Replies
    15
    Views
    1,648

    Jim, that is why there is hot gas to falsify...

    Jim, that is why there is hot gas to falsify load, to keep head up,just wondering why fan cycler and yes I understand there is a heat wheel. I have worked on many with heat wheels and the units never...
  36. Replies
    60
    Views
    4,605

    I think well I know when install a system low...

    I think well I know when install a system low ,medium or high temp you pull it down to 500 microns and use virgin refrigerant you will never have NC's in system. Excluding low pressure chillers. NC...
  37. Replies
    11
    Views
    931

    I have a yellow Jacket works great don't know...

    I have a yellow Jacket works great don't know price.I'm sure it's not cheap,employer provides all tools.
  38. Replies
    15
    Views
    1,648

    I was thinking that when I was typing but did not...

    I was thinking that when I was typing but did not add it.After two or three times it locks out.I was also wondering why it has a fan cycler when there hot gas.How far can you set dead band?Either way...
  39. Replies
    60
    Views
    4,605

    I think you guys that think N.C. stay in...

    I think you guys that think N.C. stay in condensor need to do more service work. Sooner or later you will run across it. Something that stays in one place in the system is called a restriction.
  40. Thread: VariTrane

    by local553
    Replies
    1
    Views
    529

    take one off another vav and see if it works.

    take one off another vav and see if it works.
  41. Mine would be out of that school and into private

    Mine would be out of that school and into private
  42. Replies
    60
    Views
    4,605

    [QUOTE=woody19;12470701]Why would the pressures...

    [QUOTE=woody19;12470701]Why would the pressures be low if non-condensibles were in the system. They take up volume in the condensor and that adds to increased head pressure not lower.[/QUO

    It was...
  43. Replies
    15
    Views
    1,648

    It kinda sounds like your cycling off of low...

    It kinda sounds like your cycling off of low pressure switch.You got a wheel in unit I'm guessing 100% out side air.
  44. Replies
    60
    Views
    4,605

    I ran across a unit with air in it,compressor...

    I ran across a unit with air in it,compressor would rev up big time every time that pocket of air got to compressor.Other than that pressures run low and did not cool
  45. Replies
    10
    Views
    1,174

    nothing uncommon here in st. louie town

    nothing uncommon here in st. louie town
  46. Thread: whatever

    by local553
    Replies
    107
    Views
    6,087

    Both parties suck.This same crap will go on long...

    Both parties suck.This same crap will go on long after were gone.Worried about Catholics paying for birth control.Really who gives a rats a##,different world these days.Would not want to live any...
  47. Replies
    40
    Views
    4,641

    Target, The inverted trap is up side down p-trap...

    Target, The inverted trap is up side down p-trap i'm sure it is in there to keep water in the system to keep pump primed.The only way boiler is filling is thru domestic water.The guy is either...
  48. Replies
    48
    Views
    4,031

    Hurtin,look at these post's the two clowns that...

    Hurtin,look at these post's the two clowns that say no one else has a clue they are the kind of so called techs you keep at a arms distance. I going to watch superbowl and then go to bed and get up...
  49. Replies
    48
    Views
    4,031

    yes i was talking about psc motor mybad.

    yes i was talking about psc motor mybad.
  50. Replies
    48
    Views
    4,031

    first question makes no sense to me. temp rise...

    first question makes no sense to me. temp rise over a coil, I am guessing steam or hot water then you say exchanger? Taking temp across a coil should be right after the coil.A blower not pushing air...