Search:

Type: Posts; User: truck12

Page 1 of 20 1 2 3 4

Search: Search took 0.01 seconds.

  1. Sticky: You're a funny guy. How about after a big storm...

    You're a funny guy. How about after a big storm and we have 15 sitting in the shop waiting for their replacements. All from units less than a year old. "So and So a/c INC installed this system and it...
  2. Replies
    3
    Views
    800

    My boss has no balls

    Husband and wife, not related to boss, running the company into the ground. The boss knows it yet he does nothing. I'm sick of getting the s*** calls because they pick and choose. Our work generally...
  3. Sticky: Whats wrong with the copper used in todays coils?...

    Whats wrong with the copper used in todays coils?
    Why are X13 motors still in use?
  4. no, it won't, tried that too. It doesn't...

    no, it won't, tried that too.

    It doesn't matter, I exchanged it for a new one and the new one works normally, been using it for two weeks and it works like it's supposed to. This one I started...
  5. already cleaned the sensor. This SVG2 acts...

    already cleaned the sensor.

    This SVG2 acts 100% different than the last SVG2 I had. Thats more a question that anything.
    I used the same identical tool before, it worked as expected, I'm using...
  6. I don't think it should drop when pressure is...

    I don't think it should drop when pressure is added.
    No matter what is adding pressure, it should not read a lower number.
  7. Any idea why vacuum drops when r22 in gas form is...

    Any idea why vacuum drops when r22 in gas form is added? And when the gauge is disconnected it takes 10-15 minutes for it to read OL...
  8. Fieldpiece SVG2 Vacuum Gauge not right, video

    I've used one of these a few years ago, it was a company tool. It worked well, connect it up, evacuate, and in an hour or so it would be down to 500 +/-.
    I've been using a Supco for the past year,...
  9. Does it matter? The center on the bottom right...

    Does it matter?
    The center on the bottom right side, vertical.

    No where near a field connection, not physical damage, theres also oil in the pan.
  10. Leaking Trane hyperion evap coil, no replacement available

    I found a leaking coil in a GAM5 3 ton, 3 pounds low. The customers (elderly couple) purchased the extended parts and labor warranty. Trouble is Trane is screwing them, telling us there is no...
  11. Replies
    6
    Views
    1,107

    Misdiagnosis is the common problem I've seen. Or...

    Misdiagnosis is the common problem I've seen. Or maybe I've been brainwashed by trane in thinking these units will never have problems.

    I've checked a few change outs we've done and found some...
  12. Replies
    6
    Views
    929

    Airconditioning contractors are not responsible...

    Airconditioning contractors are not responsible for attic insulation.
  13. Replies
    19
    Views
    2,632

    I've recently been called out to a job that was...

    I've recently been called out to a job that was icing up, the tech had the blower out and wired the line voltage to the wrong side of the cap and the motor was running backwards.
  14. Thats great, I don't often laugh at stuff on...

    Thats great, I don't often laugh at stuff on here. Maybe I'll try that one, thanks.
  15. He knew it was a 50 amp breaker and insisted that...

    He knew it was a 50 amp breaker and insisted that it will not trip because of heat.
    Thats what he said, not my opinion.
  16. I was on a call once because of an intermittent...

    I was on a call once because of an intermittent tripped breaker. It had a square d disconnect with a 50 amp breaker, the clips were loose and the lugs were burnt. I showed the homeowner this and he...
  17. Replies
    21
    Views
    2,650

    I think it's done by being able to put out the...

    I think it's done by being able to put out the same BTU's with less electricity/gas.

    It's like cars, thats my hobby, in the 80's we had to get 8 mpg to have 400 hp. Now you can have 500+ and get...
  18. Replies
    37
    Views
    7,956

    Was the Zebra protector blown out?

    Was the Zebra protector blown out?
  19. Replies
    40
    Views
    3,916

    I have a used 2005 Lennox in my shed, a 13ACC042....

    I have a used 2005 Lennox in my shed, a 13ACC042. It was in the scrap pile where I worked in 2005. I asked the service manager what it was doing there. He said the compressor is bad. I said can I...
  20. One thing I don't like about rheems is the coil...

    One thing I don't like about rheems is the coil fins being so close together, they clog easy.
    We are a Rheem, Goodman, and Trane dealer. Goodmans don't have this problem and trane sure doesn't with...
  21. Replies
    40
    Views
    3,916

    Well if thats the case make sure it's wired...

    Well if thats the case make sure it's wired right, check the cap, try a hard start kit. If it doesn't start tell the guy this is why you don't buy used crap, and move on.
  22. Replies
    28
    Views
    2,227

    If you worry enough those six cans of worms will...

    If you worry enough those six cans of worms will all open on their own.
  23. Replies
    40
    Views
    3,916

    no valves in a scroll. sounds undercharged.

    no valves in a scroll. sounds undercharged.
  24. Replies
    40
    Views
    3,916

    undercharged.

    undercharged.
  25. Replies
    40
    Views
    3,916

    You should have evacuated the living **** out of...

    You should have evacuated the living **** out of it with a micron gauge attached to be sure that the stolen Lennox condensing unit wasn't left open after the theft. Then WEIGH IN THE CHARGE, this way...
Results 1 to 25 of 500