  1. Replies
    18
    Views
    850

    The other possibility is that your installer set...

    The other possibility is that your installer set the heat pump lock out or "balance point" to high setting. This setting locks out heat pump operation below the selected set point. So for example if...
  2. Replies
    18
    Views
    850

    Yes based on that you are using ALL electric...

    Yes based on that you are using ALL electric heat. Have you noticed the outdoor unit is not running??

    Scroll down through the menu and look for the block that says "heat source" and make sure it...
  3. Replies
    18
    Views
    850

    Sorry I can't view the photo in its current...

    Sorry I can't view the photo in its current format from my phone.


    Sent from my iPhone using Tapatalk
  4. Replies
    18
    Views
    850

    From the main screen touch menu in the lower...

    From the main screen touch menu in the lower right corner then touch energy tracking. This will give you the option to view usage and inter how much you pay per kWh.

    This is explained on page 22...
  5. Replies
    21
    Views
    890

    To my knowledge the weigh in method is the most...

    To my knowledge the weigh in method is the most accurate method to charge a system. The problem is you need to know the exact line length. Super heat and subcool verify, troubleshoot, and aid in...
  6. Replies
    18
    Views
    850

    The Carrier 25VNA0 is a green speed unit and as...

    The Carrier 25VNA0 is a green speed unit and as so has an charging section in the installation menu. When the weather outside is warm enough it will tell you how much charge to add. if this was done...
  7. Replies
    21
    Views
    890

    Charge listed on the rating plate is for the unit...

    Charge listed on the rating plate is for the unit and 15ft of connected line set of the proper size and the matching coil(in some cases). With York and some other brands there is also a compensation...
  8. Why not just install a WaterFurnace Geothermal...

    Why not just install a WaterFurnace Geothermal system. With an IntilliZone2 damper control system. One of the options with this set up is for a first stage call to satisfy by just running the blower...
  9. Replies
    15
    Views
    1,613

    Just had a very similar problem with a Nest...

    Just had a very similar problem with a Nest hooked to a Lennox gas furnace. I am getting 14 volts on the Y terminal with only the sub base installed. It pulls the outdoor contractor in as soon as the...
  10. Replies
    44
    Views
    4,544

    Do you really think the compressor would live...

    Do you really think the compressor would live long enough pumping water to accumulate that much water in the coil. For it to get in the condenser coil it would have to go through the compressor....
  11. Replies
    44
    Views
    4,544

    Just a weak spot. Finally gave out. If nothing...

    Just a weak spot. Finally gave out. If nothing else was found I would not over think the problem.
  12. Replies
    20
    Views
    1,420

    Best zoning system Ive ever installed or worked...

    Best zoning system Ive ever installed or worked on is the carrier Infinity. Using all Infinity equipment and carrier dampers as well. The system lets you set air flow limits for each zones and runs...
  13. Replies
    9
    Views
    1,126

    Not that I endorse it but there is Aluminum line...

    Not that I endorse it but there is Aluminum line sets available. There is also a soldier that will join it to itself as well as join it to copper or brass. I know this because my company used this...
  14. "Hot Water High Limit (Domestic Hot Water Option)...

    "Hot Water High Limit (Domestic Hot Water Option)
    This mode occurs when the hot water input temperature
    is at or above 130F for 30 continuous seconds. The DHW limit status LED on the unit...
  15. Replies
    13
    Views
    1,471

    Expert recommendation...... Leave it to the...

    Expert recommendation...... Leave it to the experts. Thats how they make a living.

    If it were my house I would have it replaced because thats what the expert recommended.
  16. Replies
    21
    Views
    1,782

    UEI DTH31. Been using the same one for years....

    UEI DTH31. Been using the same one for years. Only thing I have ever done is replace the battery once a year.
  17. Replies
    21
    Views
    3,858

    Work looks amazing (with the exception of the...

    Work looks amazing (with the exception of the source piping) but Kevin is correct. You are not supposed to hook a hot water generator to a gas water heater.
  18. Replies
    14
    Views
    2,152

    Try taking the UI to the outdoor unit. hook it to...

    Try taking the UI to the outdoor unit. hook it to the unit with a short piece of stat wire. Leave the wire running to the indoor hooked up inside and outside but remove the stat wire that went from...
  19. Replies
    13
    Views
    1,006

    are you zeroing the meter to atmospheric pressure...

    are you zeroing the meter to atmospheric pressure before you stick it in the duct?
  20. Replies
    14
    Views
    2,152

    Check the stat wire you have running to and from...

    Check the stat wire you have running to and from all the Infinity connections. The green and yellow are used for communication and if you have any splices that are not 100% or have been exposed to...
  21. Replies
    8
    Views
    528

    H-10 is the gold standard of the industry. It has...

    H-10 is the gold standard of the industry. It has never let me down. If it says there is a leak. Then there is a leak. I too like to visually verify but I have learned to never doubt my trusty friend.
  22. Replies
    66
    Views
    6,357

    Im not familiar with that particular leak...

    Im not familiar with that particular leak detector. On the H-10 the low, med, and high reference the leak rate not the sensitivity. So the Low setting would be most sensitive setting.
  23. Replies
    66
    Views
    6,357

    Yes put a few oz of r22 gas in the system. Then...

    Yes put a few oz of r22 gas in the system. Then fill to a good pressure with nitrogen. If you have a H-10 try searching on Medium first and if that does not come up with anything switch it to low.
    ...
  24. Replies
    24
    Views
    1,823

    This by no means is meant to be a training tool....

    This by no means is meant to be a training tool. I only posted it in this "Tech to Tech" forum because a few people had asked about how the material was joined. The guy doing the soldiering was a rep...
  25. Replies
    24
    Views
    1,823

    Let me explain how things are done here. We...

    Let me explain how things are done here.

    We have crews that do nothing but run line sets, PVC flues, and set equipment. The service department does the actual start up of the system. The systems...