Search:

Type: Posts; User: maxscott

Search: Search took 0.00 seconds.

  1. Replies
    34
    Views
    4,000

    2020 vAV cooling only streaight duct 2021 ...

    2020 vAV cooling only streaight duct
    2021 vav cooling and heating switches from thermistor streaight duct
    2022 VAV with Electric Reheat streaight duct
    2023 VAV with Hot Water streaight...
  2. Replies
    34
    Views
    4,000

    2050 and 2051 are fan on all the time the boxes...

    2050 and 2051 are fan on all the time
    the boxes have heat and cooling
  3. Replies
    2
    Views
    1,138

    we working with a BAPI wireless room temp 4 - 20...

    we working with a BAPI wireless room temp 4 - 20 ma no luck trying to work it into a siemens system MEC
  4. Replies
    5
    Views
    1,073

    MBC keys

    Apogee has two key colors Black and White letters are the actual address keys .The white keys are /2 example key 8 is really 2
  5. Replies
    37
    Views
    12,553

    pxc

    Last time I worked on one I used hyperterminal and the MMI port.
  6. Replies
    5
    Views
    918

    SKD62U will do it

    SKD62U will do it
  7. no just when you add to the pannel the addressing...

    no just when you add to the pannel the addressing is lets say pannel 0 fln 1 point 1
  8. Replies
    32
    Views
    2,945

    MEC and a MBC are two different animals the...

    MEC and a MBC are two different animals the thread asks about MEC out put module.
    Which is a AO/AI or DO/DI like a 549-212, 549-214. But if you are asking about a MBC . The white keys are binary(...
  9. there is a dip switch seting you have set address...

    there is a dip switch seting you have set address on it . and some have a seting for speed other are universal type( fln bln)
  10. Replies
    12
    Views
    1,828

    Parts repair siemens

    http://www.isa-net.com/
    repiars some siemens parts check out web sight
  11. Replies
    21
    Views
    3,994

    MBC

    Could be node 0 or any node defined to be the server or back up server
  12. Replies
    2
    Views
    648

    TEC

    What Application? there is lots of them .
  13. Replies
    29
    Views
    3,248

    Run the port at 9600 not 38400 and it might help...

    Run the port at 9600 not 38400 and it might help ..
  14. Replies
    12
    Views
    2,965

    Datamate still works just fine I have found some...

    Datamate still works just fine I have found some times you have to set the MMI port speed down to 9600 to use Datamate with the power MEC. I did here that some one hacked Advanced and no longer...
  15. Replies
    134
    Views
    28,177

    yes and no

    To talk to U.C. Datamate Advanced will not let you change the Appl # only (editor) CIS and it dont run on XP . even if located in programs/Cis
  16. Replies
    134
    Views
    28,177

    Controls Software

    I am using a virtual machine , one as 95 to run Datamate CIS and XP Datamate advanced . It works just fine
Results 1 to 16 of 16
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event