Search:

Type: Posts; User: squirrelshot

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    39
    Views
    1,155

    Lmao- Ya- be sure to wear a helmet and knee pads

    Lmao- Ya- be sure to wear a helmet and knee pads
  2. Replies
    39
    Views
    1,155

    Lmao- Ya- be sure to wear a helmet and knee pads

    Lmao- Ya- be sure to wear a helmet and knee pads
  3. Replies
    39
    Views
    1,155

    Lol

    Lol
  4. Replies
    39
    Views
    1,155

    Any thinkers out there? Come on back

    Any thinkers out there? Come on back
  5. Replies
    39
    Views
    1,155

    I think I just figured out a way to save our...

    I think I just figured out a way to save our Country from some of this outrageous spending...**** can the EPA and hire some of the commentators on this website. They are way more qualified and...
  6. Replies
    39
    Views
    1,155

    [QUOTE=bearfromobx;18996181]Like so many...

    [QUOTE=bearfromobx;18996181]Like so many legalities, venting is based on intent. Your comment showed intent to release approximately 13 oz of R22 that did not have to be released, however a chiller...
  7. Replies
    39
    Views
    1,155

    Thanks for the feedback

    Thanks for the feedback
  8. Replies
    39
    Views
    1,155

    Thanks - I may just try that

    Thanks - I may just try that
  9. Replies
    39
    Views
    1,155

    Thanks again for the exact thing I don't need- a...

    Thanks again for the exact thing I don't need- a lecture on ethics. My customers know I do right by them. Quite honestly it's pretty offensive that this has now downgraded to whether I have...
  10. Replies
    39
    Views
    1,155

    Thanks Mason for the back up...I guess I should...

    Thanks Mason for the back up...I guess I should have phrased it better... Such as " recover by EPA approved methods in accordance with EPA regulation"....I just thought I was gonna get some technical...
  11. Replies
    39
    Views
    1,155

    Thanks Saylor for the helpful reply.

    Thanks Saylor for the helpful reply.
  12. Replies
    39
    Views
    1,155

    Thanks for all of (well most of) the replies- yes...

    Thanks for all of (well most of) the replies- yes fully licensed, insured and own my own business. Just trying to get some helpful info....I really didn't mean for thread to go south like...
  13. Thank you

    Thank you
  14. Replies
    39
    Views
    1,155

    We'll the unit only holds 13 oz to begin with and...

    We'll the unit only holds 13 oz to begin with and it's coding low-combine that with 500' of dock to lug a recovery machine/cylinder... De Minimus in my book
  15. Manufactured Housing Install question

    I have not done too many mobile home units, but It seems like many of them are Coleman units or similar.

    Is there any legal or liability reason why we can not recommend any downflow electric...
  16. Replies
    39
    Views
    1,155

    Boat AC charging question

    I am not sure if I am even remotely close to having this in the correct forum...but thought I would throw it out there. Has anyone here ever charged an ac unit on a boat?

    I have a large cruiser...
  17. Replies
    3
    Views
    297

    Thermal Imaging Camera Advice

    Hey guys- I am considering adding a thermal imager to my tool arsenal. I believe I could make money with it on duct leaks, etc. My question is does anyone have experience using this in a...
  18. Replies
    29
    Views
    1,421

    All I know is that the head pressure was crazy...

    All I know is that the head pressure was crazy high first time I looked at it- totally diff on next trip. I suspect the restriction may have been in the TXV, and along with an overcharge would cause...
  19. Replies
    29
    Views
    1,421

    Okay- so went back out there and found entirely...

    Okay- so went back out there and found entirely different situation. This time the suction reading 32 psig and relatively low head. Suction line frozen all the way up to compressor. I called it a...
  20. Replies
    29
    Views
    1,421

    Thanks - ill pull some juice and see what happens...

    Thanks - ill pull some juice and see what happens - then formulate a plan. Thank y'all for the help.
  21. Replies
    29
    Views
    1,421

    High head- normal suction

    Hey guys- heading back out tomorrow on a no cool call back. First call found pressures (410A) 110/655. ID temp around 78 and OD temp 97. Cleaned condenser and got head to drop down around 475 with...
  22. Replies
    7
    Views
    374

    I saw that chart in IMC code book. But, I still...

    I saw that chart in IMC code book. But, I still know there is a chart that shows what size your single drain line needs to be when you terminate into it from (2) or more lines. Example- (2) 3/4...
  23. Replies
    7
    Views
    374

    condensate line sizing chart

    I used to have a chart that showed proper condensate termination line sizes for instances where 2 or more condensate drain lines are connected. I see minimums for a condensate drain size per ton in...
  24. Replies
    22
    Views
    839

    Is comfort R activated in heating?

    Is comfort R activated in heating?
  25. Replies
    22
    Views
    839

    If the sensing bulb lost chg then it would shut...

    If the sensing bulb lost chg then it would shut off TXV correct?