    no the firemarshall was not attending...i thought...

    no the firemarshall was not attending...i thought they were the ones responsible for fire alarm verifications?..anyhow i found several descrepiancies that needed fixing...

    we have commissioned and...
  2. Replies
    21
    Views
    2,478

    I've done some of the AABC commissioning lately. ...

    I've done some of the AABC commissioning lately. I've had both the GC and mech tell me to ignore (on 2 seperate jobs)the spec's since it had so many unusual points to cover.
    IE..big new specs...
  3. Replies
    21
    Views
    26,521

    external static pressure = the sum of the ahu...

    external static pressure = the sum of the ahu suction/return static pressure taken approximinately 6" before the ahu and the dischrage/supply static pressure taken 6" after the ahu.


    Patrick...
  4. Replies
    11
    Views
    1,848

    yep...most likely thats air in the system. bleed...

    yep...most likely thats air in the system. bleed it out.

    Patrick
    Test/Balance
  5. Replies
    19
    Views
    2,835

    main causes i have seen are.. back of the...

    main causes i have seen are..
    back of the diffuser not insulated.
    and
    building has a negative pressure and outside air is being drawn in..ac unit turns off when temp is satisfied..warm outside...
  6. Replies
    22
    Views
    1,607

    that would make for too much outside air for the...

    that would make for too much outside air for the ahu to conditon in the summer..down here on the gulf coast.
  7. Replies
    22
    Views
    1,607

    the full story is.. 3 tons served the 1100...

    the full story is..

    3 tons served the 1100 sq'office.
    2 tons of the 5 served an adjacent
    small warehouse with rolling doors open most of the time.
    (2 400 cfm diffusers).

    1 return air grill...
  8. Replies
    22
    Views
    1,607

    the ahu serves a small office space.(1100 sq ft)....

    the ahu serves a small office space.(1100 sq ft).

    i beleive the device was a hotgas bypass controller..
    i assume it worked but need to follow up with the people that took the suggestion and used...
  9. Replies
    22
    Views
    1,607

    I have a 5 ton unit that will have some diffusers...

    I have a 5 ton unit that will have some diffusers
    capped off and don't want the coil to freeze up.

    a couple years ago had similar problem and came here and got the suggestion to use a device that...
  10. Replies
    28
    Views
    7,114

    the only time i use static pressure to determine...

    the only time i use static pressure to determine actual cfm is when i already know what the original cfm at the original static pressure is via traverse/balometer/etc.

    sp new divided by sp old...
  11. Replies
    7
    Views
    902

    Thanks Sirtab i'll check that out along with the...

    Thanks Sirtab i'll check that out along with the AABC one.


    Incontrol.. flake off.
  12. Replies
    7
    Views
    902

    anybody been through the latest commissioning...

    anybody been through the latest commissioning process whereas the test and balance contractor is required to:

    *check all the controls and operations of the domestic plumbing system...hot water...
  13. Replies
    11
    Views
    969

    ERV=energy recovery unit. without the dampers...

    ERV=energy recovery unit.

    without the dampers most of the return air will probably pull from the return grills closest to the unit...they are just a way of spreading it out by the balance...
  14. Replies
    11
    Views
    969

    on the question in the first post. the main duct...

    on the question in the first post. the main duct return air damper is used to adjust the outside air to design spec's.

    if it's an erv system..i can't fathom the need for a return air damper as...
  15. Replies
    14
    Views
    1,163

    the srt-10 runs a 13.2 1/4 mile...with a good...

    the srt-10 runs a 13.2 1/4 mile...with a good driver.
    Lightnings run high 13's-low 14's on average..stock.
    SRT---$42000
    L-----$32000
    there is already a 4 door version of the srt coming....
  16. Replies
    2
    Views
    856

    google search iaq complaint form. IAQ...my...

    google search
    iaq complaint form.

    IAQ...my former employer canceled adapting it
    when they discovered it may lead to sitting
    in a courtroom.
  17. Thread: Siemens????

    by Islander
    Replies
    14
    Views
    2,294

    my experience with them on the test/balance...

    my experience with them on the test/balance end...
    product is good...technicians good.
    Lump them in there with the rest of them...in my area at least.
  18. Replies
    11
    Views
    965

    Originally posted by deanmech I was...

    [QUOTE]Originally posted by deanmech


    I was thinking low supply air static to be up to 2"wc; medium to 4" and high over 4". Is this correct?

    ****yeah. class C to 2".
    class B to 4".
    class...
  19. Replies
    12
    Views
    730

    Iterative hvac... tons of links there you...

    Iterative hvac...

    tons of links there you should be looking at JBF.
  20. Replies
    12
    Views
    730

    ...i test/balance systems with bypass ducts on...

    ...i test/balance systems with bypass ducts on occasion and can tell you they do ok in general..i have'nt tested for exact accuracy/reponse of the bypass cfm though...mostly i see bypass dampers that...
  21. Replies
    12
    Views
    730

    build and patent it yourself. Then attend any...

    build and patent it yourself.
    Then attend any industrial/hvac
    conventions you can find.

    you could approach Trane..Carrier...TSI.. etc..
    but i would'nt unless you have protected it first.
    ...
  22. Replies
    12
    Views
    3,988

    i'd still get an engineer to do the heat load...

    i'd still get an engineer to do the heat load calcs and test/balance to adjust the boxes.
    why spend all that time ballparking it..
  23. Thread: running amps

    by Islander
    Replies
    7
    Views
    844

    you can go as high as the sf# on the name plate....

    you can go as high as the sf# on the name plate.
    often 15% higher than rated amps.

    not sure how low is good...never had a problem with
    low actual amps vs rated.
  24. Replies
    12
    Views
    3,988

    max cfm usually is about 1.1 x square footage of...

    max cfm usually is about 1.1 x square footage of space served...min cool cfm(if applicable) is about 20% of max...min heat cfm is about 50% of max.

    the 1.1 is for a typical room without tall...
  25. Replies
    24
    Views
    4,021

    single or double sensor enthalpy control along...

    single or double sensor enthalpy control along with calibrated outside air temp sensor ought to help nicely
    given don't have the the leaky bldg, negative space pressure, too much min o.a., not cold...