  1. Replies
    45
    Views
    2,853

    You may find it is difficult to flush the unit...

    You may find it is difficult to flush the unit without the service valve kits. Navien combi has a flue gas limit switch preset at 149, but it is recommended to us higher temp cpvc venting.
  2. Replies
    13
    Views
    5,298

    Looks identical to another brand "comfortstar"....

    Looks identical to another brand "comfortstar". They are made in China, and small units(<3ton) use Toshiba/Panasonic rotary compressor. They are quiet and look nice. The compressor has been used in...
  3. Only compressor froze up?

    Only compressor froze up?
  4. If you consider more about extreme weather, why...

    If you consider more about extreme weather, why not put in a P series, it will performance the same as low as the temp 5F. That means even at 5F, the unit will give same heat output as at 47F.
  5. Replies
    16
    Views
    1,404

    For high SC, maybe low ambient, non condensible....

    For high SC, maybe low ambient, non condensible.
    For low SC, dirty condenser coil or bad condenser fan.
    I dont think low airflow at evaporator and over feeding metering device will definitely cause...
  6. Thread: Low ambient

    by vibration
    Replies
    11
    Views
    928

    Under that low ambient, and maybe low load, you...

    Under that low ambient, and maybe low load, you can't check the charge in cooling. Why you doubt it? Did you weigh in, or just released from condenser?
  7. Replies
    21
    Views
    2,282

    amana once had 80v ignitor. Later, all changed to...

    amana once had 80v ignitor. Later, all changed to 120v. So if you change the board, make sure the ignitor is not 80v.
  8. Replies
    12
    Views
    1,303

    We had same issue with amana cause they put...

    We had same issue with amana cause they put something in that service valve, and no installers paid attention to that changes in installation manual. It only leaks in extremely cold weather.
  9. Replies
    20
    Views
    1,718

    When the fan runs continuously, the first thing I...

    When the fan runs continuously, the first thing I would check is limit.
  10. Faststat

    Faststat
  11. Replies
    64
    Views
    7,130

    Lennox will have new replacement for control...

    Lennox will have new replacement for control board. They already have the part number, but no price for that.
  12. Replies
    9
    Views
    844

    drain problem, then water went into pressure...

    drain problem, then water went into pressure switch and damaged the switch.
  13. Replies
    61
    Views
    3,708

    Frankly, for service, Amana/goodman is my...

    Frankly, for service, Amana/goodman is my favorite.
  14. Replies
    17
    Views
    3,139

    Normally we check static pressure (furnace not...

    Normally we check static pressure (furnace not working) and working pressure (furnace is firing), calculate the pressure drop, pressure drop is more critical.
  15. Replies
    27
    Views
    4,007

    I guess the installer drilled the hole for...

    I guess the installer drilled the hole for exhuast at a wrong pitch, so the water stays in the horizontal pipe through the wall.
  16. Replies
    42
    Views
    3,550

    The problem is you cannot get all of the reading...

    The problem is you cannot get all of the reading for all brands you service. Like you said, even amana has several different types of igniter, and they have different resistance, and sometime even...
  17. Replies
    32
    Views
    2,296

    amvm is also a modulating furnace if works with...

    amvm is also a modulating furnace if works with the series communicating tstat, amana said.
  18. Thread: Melted CSST!

    by vibration
    Replies
    10
    Views
    797

    Does the csst touch the water tank c vent?

    Does the csst touch the water tank c vent?
  19. Replies
    18
    Views
    1,031

    If it requires 2.5" and you put 3", will it cause...

    If it requires 2.5" and you put 3", will it cause problem?
  20. Did you check the flame pattern? This happened to...

    Did you check the flame pattern? This happened to me once. when I looked at the flame, one burner flame was different from the others, smaller flame. Removed manifold, found spider nest in that...
  21. Replies
    26
    Views
    2,754

    Customer replaced tstat, no heat. Found the tstat...

    Customer replaced tstat, no heat. Found the tstat energized everything, heat, cool, fan when it called for heat. Not a heat pump tstat.
  22. Replies
    8
    Views
    989

    My question is how cold was inside your house...

    My question is how cold was inside your house last year? What was your tstat set at? Maybe your old furnace had some problems so it could not keep the temperature in your house, not because the...
  23. Replies
    8
    Views
    724

    I cannot get how you calculate the heat loss. So...

    I cannot get how you calculate the heat loss. So you think the properly sized furnace will work 15 minutes and stop for 15 minutes at design temp?
  24. Replies
    19
    Views
    1,199

    I got my *. They did not notice me.

    I got my *. They did not notice me.
  25. Replies
    19
    Views
    1,199

    I am not suppose to answer your question since I...

    I am not suppose to answer your question since I am still waiting for my *. But, because my username is half of yours, just check all the screws on the outdoor unit, loose a little bit, tight again,...