Search:

Type: Posts; User: reed

Search: Search took 0.01 seconds.

  1. Thread: alarm wiring

    by reed
    Replies
    21
    Views
    1,712

    Checkout Jackson systems .com. They have a...

    Checkout Jackson systems .com. They have a simple device mm100.
  2. Replies
    8
    Views
    1,143

    I was involved in the installation of the tac...

    I was involved in the installation of the tac controls there. ( East Indianola ). That building has some thick walls. As I remember you have a boiler and chiller barrel in basement. Two tac panels...
  3. Replies
    3
    Views
    822

    Looking for a manufacturers that makes a through...

    Looking for a manufacturers that makes a through the wall mounted condensing unit. I have seen them where the units are flush with outside wall and all access is inside. Another unit i seen was a...
  4. Replies
    12
    Views
    1,055

    Are the outside air dampers closed at airhandler....

    Are the outside air dampers closed at airhandler. Sounds like it could be open and bringing in hot air with the discharge temp. being 73.
  5. Replies
    108
    Views
    12,114

    the company called comstar 1-800-328-0142 makes a...

    the company called comstar 1-800-328-0142 makes a spray just for dirty sock coils. It has fix some of our problems in the past.
  6. Replies
    2
    Views
    685

    I'm looking at a 4x4x8 walk in cooler. was a r12...

    I'm looking at a 4x4x8 walk in cooler. was a r12 now mp39. this unit has been thrown together nothing fancy. what type of pressures, sh, sc and td should this unit be running. one thing i did noticed...
  7. Replies
    13
    Views
    2,644

    looks good!!!! Only thing I don't see is a...

    looks good!!!! Only thing I don't see is a barometric draft regulator, a draft inducer and a cleanout tee.
  8. Thread: thermostat wiring

    by reed
    Replies
    3
    Views
    986

    I'm looking for a wiring diagram for landing...

    I'm looking for a wiring diagram for landing wires at base. honeywell stat #t7300f2150 or american standard #asystat705a. I got the installer's guide, no were in there about terminal landing.
  9. Thread: novar

    by reed
    Replies
    4
    Views
    1,132

    Trublshter what I was getting out. If being a...

    Trublshter what I was getting out. If being a novar service provider has it got your foot in the door on commercial stores that have novar to do more than repairing controls?
  10. Thread: novar

    by reed
    Replies
    4
    Views
    1,132

    is anybody out there a novar technology center...

    is anybody out there a novar technology center provider? and if so what are the pro's and con's of being n.t.c provider.
  11. Thread: ruud fancoil

    by reed
    Replies
    1
    Views
    645

    what is the differance between a ubhb-25j21 mfea...

    what is the differance between a ubhb-25j21 mfea and ubhb-25j18 mfea. what size coil is in it and is a piston or txv inside.
  12. Thread: HRV/ERV hoods ?

    by reed
    Replies
    7
    Views
    1,492

    they have them at graingers

    they have them at graingers
  13. Replies
    13
    Views
    2,698

    I found on two furnaces of rheem or ruud that the...

    I found on two furnaces of rheem or ruud that the fan would not come on ( stat was in fan on ) because they didn't land a motor speed on fan terminal on circuit board.
  14. Replies
    32
    Views
    13,244

    if the waterheater ties into the same chimney i...

    if the waterheater ties into the same chimney i would turn the waterheater on and checked for drafting of flue. To see if chimney could be plugged. Is your chimney lined.
  15. Replies
    6
    Views
    1,295

    thanks for the advice so far. I went to there web...

    thanks for the advice so far. I went to there web site and went threw check list. the one thing that caught my attention was.. water runs over evaporator during harvest cycle and it did when i was...
  16. Replies
    6
    Views
    1,295

    m# gy0204a s# 930860075 The problem is that the...

    m# gy0204a s# 930860075 The problem is that the ice does not stay hard during the harvest cycle. By the end of cycle there is no cubes of ice left. what should the timer be set at for pump after...
Results 1 to 16 of 25
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event