    Sounds like your IT guy needs to do a little work...

    Sounds like your IT guy needs to do a little work and make sure that the bcu ip address isnt being assigned out in a dhcp pool just a thought
  2. Replies
    6
    Views
    775

    Trane has several variables that only apply to...

    Trane has several variables that only apply to the trane profile for an MP-581 used in summit and are not lon certified these are like a multi state point but probably won't mean much to you. You...
  3. Thread: Loetec LIP

    by summit-dude
    Replies
    10
    Views
    1,148

    I have the manuals and their tech support has...

    I have the manuals and their tech support has been no help ready to give up and try another way of doing the integration. Tried the settings as a foreign device no BBMD b/c I already have one on the...
  4. Thread: Loetec LIP

    by summit-dude
    Replies
    10
    Views
    1,148

    ok got firmware updated but it still wont serve...

    ok got firmware updated but it still wont serve up any points, I have no duplicate addresses, Baud rates match any ideas
  5. Replies
    10
    Views
    1,298

    It is a standard ISA card slot 10/100 m card and...

    It is a standard ISA card slot 10/100 m card and just about any card will work as long as it is jumper configurable for 10 meg 1/2 duplex
  6. Thread: Loetec LIP

    by summit-dude
    Replies
    10
    Views
    1,148

    Loetec LIP

    Trying to integrate MS/tp to BAC-net IP through a Loytec LIP. I tried to download new Firmware and the router wont eat the code I'm using a null modem cable is this the correct cable or should I be...
  7. Replies
    4
    Views
    908

    Read/write the variables in the program instead...

    Read/write the variables in the program instead of using radio connections this is not what trane recommends but it will keep you from getting tha compile error
  8. Replies
    14
    Views
    1,394

    What kind of comm failure??? I've never seen a...

    What kind of comm failure??? I've never seen a comm failure alarm on an MP that involved the comm link, only a comm failure to an EX module or a display screen I wouldn't go ripping out the comm...
  9. Replies
    11
    Views
    1,218

    Do you have user profiles set up or does everyone...

    Do you have user profiles set up or does everyone sign in using a default username and password??? Find out what priority the overrides are at and insure that you don't have some kinda screwy CPL...
  10. Replies
    3
    Views
    736

    Reconnect the return air temp sensor and check...

    Reconnect the return air temp sensor and check the return humidity sensor and the OA humidity sensor I bet you will find one of them failed. If you find one of them failed you can disconnect the OA...
  11. Replies
    23
    Views
    5,947

    For our stuff I find that using a proportional...

    For our stuff I find that using a proportional bias, a large error dead band and long program execution works best for me. 4* error deadband, conservative gains and 15 second program execution for...
  12. Replies
    7
    Views
    1,713

    M 100 Tech is right this changed a few years ago...

    M 100 Tech is right this changed a few years ago the end user can not contact Tech support direct any more too many people trying to register more than one computer per licensed copy. If you contact...
  13. Thread: Trane BCU

    by summit-dude
    Replies
    20
    Views
    2,332

    I believe that any 10/100 ISA card will work just...

    I believe that any 10/100 ISA card will work just fine with a BMTW power down the BCU install the card hook up to the BCU and connect with summit and the program should dump into the BCU as the...
  14. Replies
    8
    Views
    1,110

    latest and greatest service pack fixes the IE 7...

    latest and greatest service pack fixes the IE 7 problem but don't use google or yahoo toolbar programs it drives summit crazy I have customers using v16 and IE7 with no problems.

    I installed V-17...
  15. Thread: Trane SCC

    by summit-dude
    Replies
    7
    Views
    725

    Don't select it, just click the dropdown arrow on...

    Don't select it, just click the dropdown arrow on the box and set it to not used thats it
  16. Replies
    4
    Views
    449

    Never seen a demo copy of rover and any disc you...

    Never seen a demo copy of rover and any disc you get ur hands on is going to make you register it before it will run. Sorry dude
  17. I have to agree with Willf the programmers don't...

    I have to agree with Willf the programmers don't allways do a good job programming for lon profiles properly. If an SCC or DAC profile is enabled and best practices have been used all you need to use...
  18. Replies
    10
    Views
    991

    Don't undestand the whole trac-net and tron stuff...

    Don't undestand the whole trac-net and tron stuff the BCI and UC lines are out and they are awesome we just had our first SC job with BCI-I's and UC 400's go in and it is sweet!!! And yes it is real...
  19. Replies
    7
    Views
    482

    Chiller dude I don't work for a franchise but do...

    Chiller dude I don't work for a franchise but do work for the factory and have tons of expierence in this you can make your own decision on who to believe, point your browser to pacific geek . com...
  20. do have to agree with willf on this the LCI's are...

    do have to agree with willf on this the LCI's are pretty consistant and we have very few problems with them.
  21. Replies
    7
    Views
    595

    I suppose I could have misundestood as well or...

    I suppose I could have misundestood as well or be just plain wron (wouldn't be the first time) but this is the only thing I could find in the LCI-I documentation for any type of heat status.
  22. Replies
    7
    Views
    595

    NVO Heat Cool is the output it is a Multi state...

    NVO Heat Cool is the output it is a Multi state output SNVT_HVAC_MODE index 40 on the LCI-I a value of 0 will be auto 1 will be heat 3 will be cool I hope this helps you and sorry it took so long to...
  23. LCI-I or LCI-R? DAC or SCC?

    LCI-I or LCI-R? DAC or SCC?
  24. Replies
    2
    Views
    1,123

    You need to tell the computer which port to use...

    You need to tell the computer which port to use it is outlined in the help menu in rover as well as the setup documentation you got with the software package If you dont have a hard copy you can...
  25. Replies
    26
    Views
    5,849

    I agree with some of what you are saying and I...

    I agree with some of what you are saying and I can assure you I've never squirmed sitting across the table from a comissioning agent though in fact I have a few that call me about advice on Trane...
Results 1 to 25 of 109
Page 1 of 5 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event