Carrier / Bryant Draft Inducer Motor 318984753, 318984-753
I have 10 year old furnace flame floats a litte going into heat exchanger. cycles out on flame senor..
When i remove vent pipe flame flow normal.. Iam thinking new draft motor. -
07-23-2012, 11:58 AM
Thread: Mechanical license exam
by klyons20- Replies
- 40
- Views
- 7,934
There are suggested books that you can read for...
There are suggested books that you can read for the test... You need to know code to pass.
-
07-06-2012, 01:53 PM
Thread: Super-Freeze 22a Refrigerant
by klyons20- Replies
- 5
- Views
- 2,164
Super-Freeze 22a Refrigerant
Super-Freeze 22a Refrigerant - R22 Freon Drop-in Replacement - 30 lb Equivalent
Anyone using the Super-Freeze 22a Refrigerant ?
What you take on it?
Any cons?
regards, -
02-06-2011, 09:26 AM
Thread: low airflow on York twinned furnaces
by klyons20- Replies
- 6
- Views
- 766
Pull fan motors and clean secondary heat coil...
Pull fan motors and clean secondary heat coil just above the fan! Use a coil cleaner.
This could be your problem -
06-21-2010, 11:35 AM
Thread: whirlpool gd5shaxlq02 ice maker
by klyons20- Replies
- 1
- Views
- 524
whirlpool gd5shaxlq02 ice maker
whirlpool gd5shaxlq02 ice make stop working..
the arms on the ice maker seem to be normally position.
There is a wiring harness that connects the ice make black white green brown. How do i... -
01-09-2010, 12:04 PM
- Replies
- 14
- Views
- 954
fan limit switch vs a fan control board
A fan is controlled by two ways a temperature switch or a fan board
The fan board will run regardless of the temp.
fan limit switch
The temperature switch will open and close the switch based... -
01-09-2010, 10:51 AM
- Replies
- 14
- Views
- 954
I work on a loading dock we use around 150k btu...
I work on a loading dock we use around 150k btu to 250k btu per door.
They run 24 hours. There no match agaist and open door. -
01-09-2010, 10:48 AM
- Replies
- 14
- Views
- 954
This is normal behavior is you are using a...
This is normal behavior is you are using a combination fan limit controll.
If you want a unit to catch up fast then put a bigger unit in or more units. -
01-09-2010, 10:43 AM
Thread: New guy can use some advice
by klyons20- Replies
- 15
- Views
- 690
u need some one in your area.. Call and get...
u need some one in your area.. Call and get prices to replace..
-
10-21-2009, 05:21 AM
Thread: Mechanical license exam
by klyons20- Replies
- 40
- Views
- 7,934
Heating and Cooling Essentials
Heating and Cooling Essentials (Hardcover)
by Jerry Killinger
Jerry Killinger (Author)
› Visit Amazon's Jerry Killinger Page
Find all the books, read about the author, and more.
See search... -
10-19-2009, 09:51 PM
Thread: Mechanical license exam
by klyons20- Replies
- 40
- Views
- 7,934
Buy book heating and cooling essectians by...
Buy book heating and cooling essectians by ladoona read heating section
-
09-05-2009, 11:39 AM
Thread: ECM Motor but not Variable Speed
by klyons20- Replies
- 16
- Views
- 18,920
use less energy
[QUOTE=rChris;1511988]Not looking like Rheem makes a VS furney, just a 2 stage that has a ECM motor.
So if that's the case, could someone esplain what's so great about these motors. Looked at the... -
08-20-2009, 07:50 AM
- Replies
- 9
- Views
- 807
dirty coil
A dirty filter can not cause a coil to leak. These new puron system are under a lot more preasure than r-22. So if everything is not done perfectly in the installation you will get leak down the...
-
07-22-2009, 06:39 AM
Thread: Contactor not pulling in
by klyons20- Replies
- 21
- Views
- 3,027
make sure control voltage is constant
Make sure control voltage is present to determine if contactor is not working.
I feel like something in the circut is opening up. -
07-21-2009, 04:33 PM
Thread: Quiet Running Ac Unit
by klyons20- Replies
- 4
- Views
- 475
Quiet Running Ac Unit
Who makes the quiet running Ac Condener R-22.
I had a magazine that show all the unit and the decimal rating.
Iam replacing a condenser and the costumer insist on a quiet running system.
I will... -
07-15-2009, 04:08 PM
- Replies
- 32
- Views
- 4,208
This calls are a pain in the behind. You have to...
This calls are a pain in the behind. You have to pump down the system put an 160 psi of nitrogen and do a buble test. Close the valves and come back the next day to see what side is leaking the a...
-
12-04-2007, 04:31 AM
Thread: gas vent termination height?
by klyons20- Replies
- 16
- Views
- 1,186
mechanical code book
Normally the BW vent change to B vent once it enters the attic. So you would use the same code that applies to b vent. Slop of the rood decides how tall the vent pipe should be. As long as this is...
-
02-24-2007, 09:42 PM
Thread: Old furnace control/ relighting
by klyons20- Replies
- 14
- Views
- 805
ok
set t stat to lowest setting . you only want to keep it above freezing.
regards,
Kelvin -
12-31-2006, 07:55 PM
- Replies
- 8
- Views
- 1,920
hello
Piece where are you from?
-
11-29-2006, 02:43 PM
Thread: Detroit Michigan Area Apprenticeship
by klyons20- Replies
- 2
- Views
- 777
Are they any beginners that need a little on the...
Are they any beginners that need a little on the Job Training? You will provide the free help. I will provide you the experience.
Regards,
Kelvin Lyons -
11-21-2006, 09:48 PM
Thread: Am I crazy? Tankless water heater ....
by klyons20- Replies
- 11
- Views
- 904
dont do it
Dont waste you time .. These units will not fit most applications..
regards,
K -
11-11-2006, 06:44 AM
Thread: Goodman Furnace
by klyons20- Replies
- 2
- Views
- 519
Why do the good man sound like a cannon ball when...
Why do the good man sound like a cannon ball when starting.
I need a quiet furnace for a job installation in the attic above the bed room. I am on a tight buget.
Goodman product or comfort air... -
11-11-2006, 06:41 AM
Thread: 58MVP code 13 & 33
by klyons20- Replies
- 16
- Views
- 1,370
Call a tech
We give advice! I can not tell you how to fix that problem, plus it could be so many things until if you dont have a volt test you can not fix it.
regards,
K -
10-28-2006, 10:52 AM
Thread: REFRIGERATOR WHIRLPOOL
by klyons20- Replies
- 3
- Views
- 446
ED25TEXHW01 REFRIGERATOR WHIRLPOOL Model of...
ED25TEXHW01 REFRIGERATOR WHIRLPOOL
Model of my whirlpool
THERMOSTAT ASSEMBLY 2198202
I have whirlpool that I am having problems with.
The coil freezes up over time and cause the unit to run... -
09-21-2006, 02:00 PM
Thread: Single vs. Dual Stage
by klyons20- Replies
- 26
- Views
- 2,500
hi fire furnace
It depends on how the dual stage is setup . Robo.
The little jumper on the board and weather you have a two stage t-stat.
Now explain to me how the furnace will know to go into hi fi mode after...