  1. I am a HACK! I have a Texas HVAC Lic. I have...

    I am a HACK! I have a Texas HVAC Lic. I have general liability insurance, I have a service van a CPA an EPA certification all the proper tools charge accounts with all of my venders an education and...
  2. [QUOTE=MM#7;11022692] Do they have in...

    [QUOTE=MM#7;11022692]


    Do they have in writing? Does it matter, does it need to be in writing? Will you sleep better at night all snuggled up in your night gown if it's in writing? I take it for...
  3. I am an American Standard dealer and yes they do...

    I am an American Standard dealer and yes they do recommend using a torch. I remember when taking the tour of the Tyler plant they brought it up in front of the whole group. I’ve done it a few times...
  4. Replies
    53
    Views
    3,260

    So let me get this straight… its 111* outside and...

    So let me get this straight… its 111* outside and your indoor temp comes up to 79* during the peak of the day that’s a 31* temperature difference!

    Just what exactly is the problem?
  5. Replies
    3
    Views
    1,756

    Actually it's 7.9 inches from the top as a...

    Actually it's 7.9 inches from the top as a minimum. Also requires 8 feet minimum from the floor but hey what are you gonna do about it? It works and the customer is happy!

    Would you care to...
  6. Replies
    3
    Views
    1,756

    LG Ductless Heat Pump

    Here is a Ductless Heat Pump I installed recently. Let’s hear it what do you like/dislike about it?

    Also when I arrived on site the home owner had decided he would hang the cassette... no biggie...
  7. Replies
    22
    Views
    4,260

    I see where the drain pokes out at the bottom of...

    I see where the drain pokes out at the bottom of the 90*
    NICE work!
  8. When I install my Daikins I run 14/3 Indoor...

    When I install my Daikins I run 14/3 Indoor Romex. I run it in ½ inch flex into the lineset channel about 14 inches. Then the remainder is simply run with the refrigerant lines inside. I use the 14/3...
  9. Replies
    19
    Views
    1,495

    I used to cut and blow stopped up lines with my...

    I used to cut and blow stopped up lines with my Gallo gun... until I heard a pop then noticed that the elbow at the end where it turns down into the wall blew off due to lack of quality installation....
  10. If you were here in Texas I would suggest a...

    If you were here in Texas I would suggest a 15KBTU Daikin Ductless Heat Pump! Extremely efficient and whisper quiet.
  11. Replies
    18
    Views
    5,881

    Why did you install a B-model heat pump with a...

    Why did you install a B-model heat pump with a premium AHU? Also what is that silver foil crap on the line set?

    Did you use mastic on all of your connections inside like plenum to AHU? Oh… and...
  12. Replies
    17
    Views
    2,477

    Considering you’ve already stated that your...

    Considering you’ve already stated that your condenser is under warranty I’d say they are trying to bend you over. They believe they have you pushed against a wall.

    I’d get the big boss involved...
  13. Replies
    25
    Views
    5,637

    This is what id like to do to the guys that do...

    This is what id like to do to the guys that do that kinda crap!

    :beat: :beat: :beat:
  14. Replies
    25
    Views
    5,637

    Disconnect behind the condenser is no good, the...

    Disconnect behind the condenser is no good, the mastic looks horrible, AHU not properly hung, refrigerant lines look like they are run in downspout bought at Home Depot. I CANT STAND CONTRACTORS THAT...
  15. Replies
    4
    Views
    1,239

    Looks clean… I sure like the way Slimduct cleans...

    Looks clean… I sure like the way Slimduct cleans things up. What about the cassette any pics of it?

    Here is a Daikin I did recently.
  16. Replies
    136
    Views
    21,189

    It looks like the vacuum pump is less than a foot...

    It looks like the vacuum pump is less than a foot away from the Micron gauge to me. Just an observation... :whistle:

    I have a similar setup but I pull the micron gauge at the last minute before...
  17. Replies
    7
    Views
    1,462

    Power head/flat/inside/maybe/IDK/what does the...

    Power head/flat/inside/maybe/IDK/what does the outdoor TXV have to do with it in cooling?

    Should not have more than a 5 to 7 degree Delta T across....

    I rarely see bad reversing valves.......
  18. Replies
    27
    Views
    6,253

    Can you put a condenser under a deck? You can...

    Can you put a condenser under a deck?

    You can put that sucker wherever you like! I will simply bill accordingly….
  19. Replies
    53
    Views
    3,142

    Trying to heat and or cool a shop by ducting into...

    Trying to heat and or cool a shop by ducting into a system that is designed to heat and cool your home is a bad idea! Besides does your shop need to be the same temperature as your bedroom or living...
  20. I second what Joker has said... I have made GOOD...

    I second what Joker has said... I have made GOOD money replacing these relays.

    As a matter of fact when I replace indoor blower motor's on Goodman AHU’s you get the motor, run capacitor, and...
  21. You can feel sorry until you turn blue in the...

    You can feel sorry until you turn blue in the face! I have many satisfied customers and I always go above and beyond for them.

    Many manufactures DO NOT require or advise against using solvent...
  22. Trane & American Standard both advise against...

    Trane & American Standard both advise against using flushes when replacing equipment. I have flushed lines with flush kits and flushed with nitrogen only.

    I rarely get much oil out of the...
  23. Replies
    11
    Views
    8,724

    Daikin all the way! We had temps in the teens...

    Daikin all the way! We had temps in the teens recently and all was nice and cozy inside. I have many customers with Daikin systems as well and they praise them.
  24. Replies
    28
    Views
    6,310

    No good

    Uh… maybe someone can explain how the hell are you supposed to service this thing? Is the front of the AHU facing the block wall? Is that transition insulated? Was there a permit pulled?

    What is...
  25. Replies
    25
    Views
    5,234

    It’s amazing how people don’t realize they are...

    It’s amazing how people don’t realize they are not doing themselves any good! No fan motor turns into compressor failure. $$$