    Primary bath fan bringing on a/c???

    Good evening. I went to a job today where the primary bath fan was wired to a switch in the hall way. That went to a relay in the mechanical room which then went to the R&G terminals on the furnace...
  6. Thread: rheem 13pjl

    by kenadiens
    Replies
    12
    Views
    1,540

    We won't even quote the cubes any more. If it's...

    We won't even quote the cubes any more. If it's gonna be Rheem it's gonna be a Prestige.
  7. Replies
    0
    Views
    372

    zonex distributor in Canada??

    Any one know of a zonex distr. in B.C,Canada.
    Thanks,
    Ken
  8. Replies
    10
    Views
    973

    out to lunch...

    I was thinking hi eff. and am totally wrong but can't figure how to edit my post. As soon as I posted I knew I screwed up. Sorry.
  9. Replies
    10
    Views
    973

    I believe the max termination seperation is 18"....

    I believe the max termination seperation is 18". Going off memory I don't have the installs infront of me.
  10. Thread: vacuum oil

    by kenadiens
    Replies
    25
    Views
    1,471

    Do you guys use copper lines or just your hoses?...

    Do you guys use copper lines or just your hoses? The specs call for copper but that doesn't seem practical to me. Sorry don't mean to Hi jack.
  11. Replies
    7
    Views
    1,081

    Got back to it this morning and check the...

    Got back to it this morning and check the settings. The ecto for cooling stages was on default. I changed to #1 and and all was good. Second compressor fired up and and SA went down to 47 RA was 70....
  12. Replies
    7
    Views
    1,081

    energy management system. Got it!!:) Thermostat...

    energy management system. Got it!!:)
    Thermostat controlled.
  13. Replies
    27
    Views
    3,342

    could it be that Y1 is your econo and your comp...

    could it be that Y1 is your econo and your comp isn't getting the call on Y2?
  14. Replies
    7
    Views
    1,081

    At the risk of sounding like an idiot. What is an...

    At the risk of sounding like an idiot. What is an EMS?
  15. Replies
    7
    Views
    1,081

    high pressure, power off, low pressure. I think I...

    high pressure, power off, low pressure. I think I might be on to something though. If the factory default was left in place. The Y1 would be the economizer, Y2 the #1 compressor and nothing for the...
  16. Replies
    7
    Views
    1,081

    lennox lgc 120...

    Second stage compressor won't come on unless reset button is pushed. Only error codes were 14, 82, 23, 24. Second stage comp. only comes on a couple times for about 3 minutes or so, then not again...
  17. Replies
    13
    Views
    1,012

    3 ton system. cfm came to 1250.

    3 ton system. cfm came to 1250.
  18. Replies
    13
    Views
    1,012

    No. My first thought was non condensables but not...

    No. My first thought was non condensables but not having my recovery tank or a new filter I figured I'de double check the other options and Air flow was number 2 on my list. It was smack on and I...
  19. Replies
    13
    Views
    1,012

    now there would be a surprise.

    now there would be a surprise.
  20. Replies
    13
    Views
    1,012

    Ya it is charged for 15 feet. The line with 90's...

    Ya it is charged for 15 feet. The line with 90's added was 17 feet.
  21. Replies
    13
    Views
    1,012

    It was a split system and Rheem will definately...

    It was a split system and Rheem will definately be getting a bill. I haven't seen it yet on a package unit.
  22. Replies
    13
    Views
    1,012

    Rheem/Weatherking factory over charged.

    Anyone have this happen to them. New install and the head pressure was bouncing around and ended up 475 vapour pres. was 115. These readings are in heat mode. 50 F OT. 65 RAT. subcooling was through...
  23. Replies
    10
    Views
    934

    Thank you rundawg for your help. Very much...

    Thank you rundawg for your help. Very much appreciated.
  24. Replies
    10
    Views
    934

    The heating requirement was 71000 btu.

    The heating requirement was 71000 btu.
  25. Replies
    10
    Views
    934

    Do you know if the cfm will go down to the 800...

    Do you know if the cfm will go down to the 800 range?