    72 degree water sounds too cold for a screw .I...

    72 degree water sounds too cold for a screw .I believe design is 85 in .There are no guide vanes, but a slide valve .I would log the machine and check the approaches.225 sounds high.I would be...
  2. I carry a drum heater on my truck at all times.It...

    I carry a drum heater on my truck at all times.It has an adjustable thermostat on it.Its a heck of alot lighter that carrying a recovery machine up on the roof and alot faster than a halogen lamp.
  3. Replies
    10
    Views
    2,667

    The oil pump back proceedure works well if its...

    The oil pump back proceedure works well if its tripping on the oil level switch.There are no oil heaters on the HXCs,on the newer hxcs ,the transducers arent calibratable, but certainly a good idea...
  4. Replies
    12
    Views
    1,245

    Ideally yes,I needed my boss to step up to the...

    Ideally yes,I needed my boss to step up to the plate and buy one.
  5. Replies
    12
    Views
    1,245

    I have used a triple evac when I had a chiller...

    I have used a triple evac when I had a chiller barrel freeze up .I replaced the chiller barrel, but there was plenty of moisture in the system.It took me a week and a half to pull a good micron...
  6. Replies
    13
    Views
    1,389

    So what if the flow swith fails?There needs to be...

    So what if the flow swith fails?There needs to be a secondary safety imo.A manual reset low temperature cutout would probably do, set to 34 degrees.
  7. Replies
    10
    Views
    2,667

    You cant run that machine with 66 degree water...

    You cant run that machine with 66 degree water going thru the condenser.Design on those machines is 85 in and 95 out.Somehow you need to warm up the water.You can try throttling down the leaving...
  8. Thread: Carrier Manuals

    by budglo
    Replies
    19
    Views
    6,269

    Hvacpartners.com is your friend.None of the...

    Hvacpartners.com is your friend.None of the manufacturers are gonna give you teardown manuals for free.Slamming a company just because you didnt get your way will get you nothing here.I dont think...
  9. Replies
    14
    Views
    10,832

    I would put it at the highest point in the...

    I would put it at the highest point in the system.Thats the most likely place for air to get trapped.I would put a ball valve there so you can remove it and change it out when neccesary.And you can...
  10. Replies
    142
    Views
    5,474

    I wonder if he ever measured the discharge line...

    I wonder if he ever measured the discharge line temperature?If it got hot enough to blow the high temperature device then the discharge had to get plenty hot .If his guage only read 140, there is a...
  11. Replies
    21
    Views
    1,274

    I see way too many suction driers out in the...

    I see way too many suction driers out in the field that are either left in or installed incorrectly.I usually replace the oil , refrigerant and liquid line driers with acid cores and then replace...
  12. Replies
    51
    Views
    7,282

    Yep,had the same problem with a Carrier...

    Yep,had the same problem with a Carrier screw.Machine was on the roof and the piping left the barrel and 4 feet later did a 90 and went straight into a tank 40 feet below.Put a circuitsetter in and...
  13. Replies
    18
    Views
    2,117

    .It sounds to me for sure like an oil return...

    .It sounds to me for sure like an oil return problem.I would find out what kind of ambient controls are on the unit and at what pressures they are able to maintain.It could be that an unloader is not...
  14. Replies
    91
    Views
    29,988

    I agree, they were a little ahead of their...

    I agree, they were a little ahead of their time.Lets face it , most of the GTs are getting up there in years too. I actually have not replaced a ton of exvs on this particular model.Sensors is...
  15. Thread: $$$$

    by budglo
    Replies
    38
    Views
    2,169

    Unfortunately this happens more often than I care...

    Unfortunately this happens more often than I care to admit.I was sent on a manufacturer specific control job and was told i needed a software 2 hrs away from the office.I was told a helper was gonna...
  16. Thread: $$$$

    by budglo
    Replies
    38
    Views
    2,169

    It isnt always the techs fault for not being...

    It isnt always the techs fault for not being profitable.I have been out on jobs where the salesman has really missed the mark in selling a quoted repair or a contract pm where they just give you...
  17. Thread: $$$$

    by budglo
    Replies
    38
    Views
    2,169

    Non union companies that tell you they start...

    Non union companies that tell you they start their guys out at 25 are usually talking about before benefits.Sometimes they will include health insurance.My package is worth about 54.00 an hour...
  18. Replies
    14
    Views
    2,474

    I understand your dilemma, but re-engineering the...

    I understand your dilemma, but re-engineering the machine is not the answer.Those exvs are stepper motors and unless the new exv has exactly the same steps then you are just asking for trouble.I have...
  19. Thread: Carrier CLO

    by budglo
    Replies
    28
    Views
    2,498

    I would check the delta t across your evap to...

    I would check the delta t across your evap to make sure you dont have an airflow problem that presents itself when the vav boxes shut down at night.Also check to see if it could be the freezestat.
  20. Replies
    15
    Views
    3,430

    I would check to see what the design tower water...

    I would check to see what the design tower water is. Usually it is 85 in 95 out.When it falls below 80 degrees the machine usually runs into problems.Also , what type of condenser water valve do you...
  21. Replies
    11
    Views
    1,139

    Like he said "check the strainer".Its...

    Like he said "check the strainer".Its plugged.While you are at it , check the flow switch for accuracy.Sounds like it might need adjusting.
  22. Replies
    1
    Views
    443

    any 601 fitters?

    I am looking to relocate from ohio to wisconsin and was wondering how the work is for the service fitters.I am a journeyman service fitter and work for one of the manufacturers .I have worked for...
Results 1 to 22 of 59
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event