Search:

Type: Posts; User: filter87

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    8
    Views
    1,217

    After I posted the thread I knew this question...

    After I posted the thread I knew this question will come up. Could not read anything on it. That was the first thing I checked but missed to write it.
  2. Replies
    8
    Views
    1,217

    Is it r-22 or 404a ?

    Water cooled Copeland KWMB-0075-CAV on the freezer.
    I am not sure if it on 404a or R-22. Completly out of refrigerant so could not check the running pressure.I will appreciate any help.
  3. Replies
    14
    Views
    1,127

    Three weeks ago I was working on reach in cooler...

    Three weeks ago I was working on reach in cooler as I was about to leave customer asked me to look at the walk in cooler for meat .
    It was working OK but the meat turns little black on top in the...
  4. Replies
    3
    Views
    979

    Thanks!

    Thanks!
  5. Replies
    3
    Views
    979

    Vacuum pump capacitor

    Anybody knows the voltage and microfarad rating of capacitor for 6 cfm yellow jacket. I bought it last year. The motor was huming .Lost the one I removed from the pump.
  6. Replies
    21
    Views
    1,473

    We were told during manufaturer training that...

    We were told during manufaturer training that 404A is actualy near azeotropic blend of R 125,R-43a &R-134a and since their boiling point is very close fractionation is possible but only if you are...
  7. Replies
    21
    Views
    1,473

    I have been told by few people that you can...

    I have been told by few people that you can actualy charge 404a in vapour form .
  8. After reading here I bought YJ 69075 and ...

    After reading here I bought YJ 69075 and manifold as some of you guys have it. I returned it back yesterday without using it because it was very bulky. If somebody just works in the shop than this...
  9. Replies
    14
    Views
    939

    Thanks again Replaced the TXV & drier, its...

    Thanks again
    Replaced the TXV & drier, its running ok .
    Will go again to make sure everything is ok.
  10. Replies
    14
    Views
    939

    Thanks for the replies Coil is not frozen New...

    Thanks for the replies
    Coil is not frozen
    New LL drier
    Indoor unit (on the cooler)
    Does not have LL solenoid
    No frost on the TXV and external equaliser line.
  11. Replies
    14
    Views
    939

    WIC suction press. not rising

    WIC, R-134, CI set at 33 psi, CO at 16 psi,.Temperature in the cooler goes up to 52 and the suction will be still at 20 psi (off cycle) and when it finaly goes up and Comp. starts , suction again...
  12. How much you paid far the YJ. So like Appion G5...

    How much you paid far the YJ.
    So like Appion G5 far recovery there is no clear opnion on micron guage. Thanks everybody far replys
  13. Which micron guage do you recommend for mostly refrig.work

    I mostly do small ref.work and now looking for new micron guage. I have been using supco and now thinking of buying Yellow Jacket 93865/ 69075.
  14. Replies
    44
    Views
    2,831

    Be nice .Don't try to be an a******.I said I...

    Be nice .Don't try to be an a******.I said I changed it momentarily .I know what can happen at 3500 rpm. I can not understand why are you acting like you know evrything while you are contadicting...
  15. Replies
    44
    Views
    2,831

    Thanks for the help. I do not have the annie but...

    Thanks for the help. I do not have the annie but changed the winding connection momentarily for reverse rotation and it worked. Compressor is running since morning. Told customer to call somebody...
  16. Replies
    44
    Views
    2,831

    Thanks Everyone

    Thanks Everyone for the replies.
    The reason I did not change the compressor and not going to is, this is the third compressor in three months (mine first) for the beer cooler since its new...
  17. Replies
    44
    Views
    2,831

    AEA4430YXA Compresser short cycling on O/L

    Condenser mod# AEA4430YXAXB Short cycling on overload.Winding is OK. Checked with megger not grounded. C_S_R resistance OK. Replaced relay, overload and capacitor though found nothing wrong with the...
  18. Replies
    6
    Views
    3,124

    Thanks anyway I did remove both set screws

    Thanks anyway I did remove both set screws
  19. Replies
    6
    Views
    3,124

    Hobart dough mixer H-600T

    I have been trying to take out the broken pin (holds the dough mixing hook) with no luck.Tried almost everything heating it, tried to drill it with carbide drill,WD-40. Checked with vernier caliper...
  20. First of all I apologies to Icemeister,...

    First of all I apologies to Icemeister, frogensolid,and k fridge for not coming back after the problem was solved. As Ice said I adjusted txv and differential and it is running OK since than.
    ...
  21. First of all I apologies to Icemeister,...

    First of all I apologies to Icemeister, frogensolid,and k fridge for not coming back after the problem was solved. As Ice said I adjusted txv and differential and it is running OK since than.
    ...
  22. Thanks frozensolid, the coil is not frozen and...

    Thanks frozensolid,
    the coil is not frozen and I just cleared the glass and added little bit more for receiver.
  23. Humidity problem in W/C after change to 409a

    I have changed walk in cooler unit Tecumseh model # AH256RT-169, Sr # 8E7361106 from R12 to 409A last week. It's running OK with temp 40*F (pizza store) but the customer just called me complaining...
  24. Replies
    36
    Views
    8,995

    Thanks Ice

    Thanks Ice
  25. Replies
    36
    Views
    8,995

    sorry starved

    sorry starved