  1. Thread: NAE Query

    by phantomtech
    Replies
    12
    Views
    520

    You need to select all and then use the action...

    You need to select all and then use the action tab command.
  2. Replies
    9
    Views
    1,331

    Stromquest has replacement coupler for the...

    Stromquest has replacement coupler for the AP-VMA1420-0
  3. Replies
    9
    Views
    827

    The rearview camera mounted in the lisense plate...

    The rearview camera mounted in the lisense plate bracket gives a much greater view than you could get out the rearview mirror.
  4. Replies
    7
    Views
    926

    The SA bus (Sensor actuator bus) is for IOMs to...

    The SA bus (Sensor actuator bus) is for IOMs to expand the IO count of the NCE and addressable sensors like the tstat.
    The FC bus is for field controllers. On the NCE you have to order the NCE with...
  5. Replies
    1
    Views
    440

    I had this problem years ago on a different...

    I had this problem years ago on a different device. I added a 8ohm resister inline with the signal to load the circuit and it has worked ever since.
  6. Replies
    3
    Views
    506

    Install a supply and return air flow station and...

    Install a supply and return air flow station and calculate the outside air.
  7. Replies
    8
    Views
    525

    If these controllers are 11 years old you...

    If these controllers are 11 years old you probably need to upgrade the firmware in all off them. Chances are your HVACpro is a newer rev.
  8. Thread: VMA1620

    by phantomtech
    Replies
    2
    Views
    872

    There is no pressure dependent application....

    There is no pressure dependent application.
    However this is what I dowith the N2 1420 VMAs You can try this for the 1620 and see what happens.
    When the DP sensor is unreliable the VMA will operate...
  9. if you have smoke fire dampers they may be...

    if you have smoke fire dampers they may be closing to fast on power failure and tripping the hi static.
  10. Replies
    5
    Views
    668

    Renut the NCE and use the extended update.

    Renut the NCE and use the extended update.
  11. Replies
    20
    Views
    1,884

    Remove the old ADS from the network. Connect the...

    Remove the old ADS from the network. Connect the new ADS to the network and the NAEs will apper if all your settings are correct. The ADS does not assign the NAEs. The NAEs look for the site director...
  12. Replies
    8
    Views
    1,188

    If you want to prove flow and direction you can...

    If you want to prove flow and direction you can install an onicon flow meter.
    This will give direction of flow and gpm thru the chiller.
  13. Replies
    29
    Views
    2,194

    Ready Access Portal is free with the ADS/ADX...

    Ready Access Portal is free with the ADS/ADX software since Rev 4.1
  14. Replies
    29
    Views
    2,194

    Look into the ready access protal. it will do...

    Look into the ready access protal. it will do what you want.
    it is HTML and nio java needed.
  15. Replies
    2
    Views
    505

    Just installed one today with 8 wireless sensers...

    Just installed one today with 8 wireless sensers in an exihibit hall.
    Everything went as expected with no problems. After you add the wireless superviser and the points online you will need to reset...
  16. Replies
    16
    Views
    1,298

    Just a note. If you have user views on both...

    Just a note.

    If you have user views on both NAE's the user views on the non site director will be lost. Only the site director can have user views. Before you change the site director export the...
  17. Replies
    13
    Views
    1,042

    Open the DMO file in notepad and remove the *...

    Open the DMO file in notepad and remove the * from infront of the short name.
  18. Replies
    21
    Views
    1,919

    I had a customer that wanted to set the day and...

    I had a customer that wanted to set the day and time to change lead/lag on his pumps every week. He was only there once a week. This is the LCT process to do that. This process looks at the day of...
  19. Replies
    4
    Views
    492

    If you want to change the setpoint from the...

    If you want to change the setpoint from the supervisory controller, map in the Common Setpoint (PM6K1) from the .prn file, generated by HVAC Pro, as PMK36. In the controller configuration, change the...
  20. Set the baud rate on the NAE to 38.4

    Set the baud rate on the NAE to 38.4
  21. Replies
    4
    Views
    412

    Which vender device is it. Are you sure that this...

    Which vender device is it. Are you sure that this device supports direct mapped points without the use of cs objects.
  22. Replies
    19
    Views
    1,637

    Bad Idea. If you value your free time. I...

    Bad Idea.

    If you value your free time.

    I had a controls friend that thought he would automate everthing in his house.
    Every time he was out fishing or riding his motorcycle the wife would call...
  23. Replies
    27
    Views
    1,367

    I was told by a PC tech once that if the hard...

    I was told by a PC tech once that if the hard drive fails wrap in in a plastic bag and put in the freezer overnight. After you reinsatal it might run long enough to back up your data.
  24. Replies
    9
    Views
    6,848

    Check the baud rate on all devices.

    Check the baud rate on all devices.
  25. We use the Edgeport/1 usb to serial adapter from...

    We use the Edgeport/1 usb to serial adapter from Digi. It comes with a setup disk and will permanatly assign the com port you want.
    If I plugin the adater to any usb port on my laptop it...