    Unlevel OD unit

    On two separate occasions I have been called out to level a OD unit that has settled. A month or better goes by and I get called out for a No Cool, both calls were a locked up condenser fan...
  2. Replies
    6
    Views
    707

    How does this stat work

    I got stuck in the hospital for a long day and was about to lose my mind. I noticed this thermostat on the wall and I started to tinker with it. I tried to look it up on the web but couldn't find...
  3. The system is over charged. I would also adjust...

    The system is over charged. I would also adjust the balance point down to around 30. We install Lennox equipment and set ours to 25, at 40 your HP will be locking out all the time. (Depending on...
  4. Replies
    8
    Views
    744

    I had a goodman unit about 3 weeks ago doing a...

    I had a goodman unit about 3 weeks ago doing a very similar thing, lucky I caught it in the act. Had plenty of negative pressure from the draft indoucer ( don't remember the exact "wc) the ignitor...
  5. Replies
    9
    Views
    686

    Depending on your service rates, you might find...

    Depending on your service rates, you might find it cheaper to just replace it. I've had a few take a real long time to reset even with a vac and blow dryer. From now on ill hit it with the vac...
  6. Replies
    8
    Views
    744

    I would check the pressure switch, sounds like it...

    I would check the pressure switch, sounds like it might be opening during a call for heat.
  7. Replies
    8
    Views
    639

    When heating with the heat pump your blower will...

    When heating with the heat pump your blower will be powered by the cooling terminal not the heat terminal. Your Delta with the heat pump is going to depend on the O/D temp. In my region it's in the...
  8. Replies
    1
    Views
    427

    Carrier Heat Pumps

    Recently worked on a R22 2 1/2 ton carrier heat pump the showed a restriction in heating mode. I removed the piston and found .059. My question is " should the O/D position match the tonnage of...
  9. Replies
    2
    Views
    342

    Fieldpiece SRL2 Leak detector

    I purchased the SRL2 back in May after reading several good review. I have yet to be impressed with this instrument, sometimes I think I might have a faulty piece of equipment. I'm constantly...
  10. Replies
    615
    Views
    108,841

    I had a OT call come in one night around 10pm....

    I had a OT call come in one night around 10pm. Customer complaint was they hear a beep coming from the Tstat. I informed her that it seemed unlikely to be coming from the hvac equipment but she was...
  11. Replies
    50
    Views
    4,913

    The pulse furnace is actually pretty easy to work...

    The pulse furnace is actually pretty easy to work on. You only need 3 things for it to work. Gas, Spark, and Combustion Air. From what you said it sounds like you didn't have air. The furnace...
  12. Replies
    14
    Views
    2,865

    I work for a Lennox dealer and we have found the...

    I work for a Lennox dealer and we have found the best way to do this is to remove the 4 screws on the top of the furnace cabinet. Pull out and lift on the panel (1/2 flange on the end ). You may...
  13. This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  14. Replies
    8
    Views
    1,743

    Best R-410A leak detectors

    It's coming up on that time of year again in my area, A/C season. There are more 410 units every year and I'm still having trouble finding a leak detector that I feel confident in. I have the h10...
  15. Replies
    37
    Views
    3,513

    Just replaced one 2 days ago. Part # 28F01....

    Just replaced one 2 days ago. Part # 28F01. Pricing is about right. Use OEM the first time or you will be buying it for them next week.
  16. Wrap your OD coil with plastic and get your head...

    Wrap your OD coil with plastic and get your head pressure up around 250, and check like normal. Some Indoor load is ideal but not always possible. I believe in checking subcool and superheat...
  17. Replies
    7
    Views
    1,278

    I highly doubt it needs a new flame senor, it is...

    I highly doubt it needs a new flame senor, it is probably the method you are using to clean it. Use low abrasive steel wool. (Not sand paper) Also if the furnace is in a laundry room that could be...
  18. Thread: Ky

    by JUSTADDSOMEMORE
    Replies
    1
    Views
    405

    Ky

    I've been working in the hvac field for 7 years. Worked all 7 for the largest residential hvac company in Louisville, Ky. Most of my experience is in residential equipment, but I'm starting to train...