Search:

Type: Posts; User: skpkey9

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    3
    Views
    260

    LMAO Too Right, Unless he lucks out and unit is...

    LMAO Too Right, Unless he lucks out and unit is still under warranty....other then that you are so right..
  2. Replies
    3
    Views
    260

    Very easy job, Hardest part is removing the...

    Very easy job, Hardest part is removing the auger, may need to use a puller tho.....

    Hope this helps
  3. Thread: Service manual

    by skpkey9
    Replies
    34
    Views
    996

    Spoken like a true ass !!! Not to mention very...

    Spoken like a true ass !!! Not to mention very unoriginal

    You don't know me as well as I don't know you, so you can keep your little comments to yourself.

    You haven't a clue except to argue...
  4. Thread: Service manual

    by skpkey9
    Replies
    34
    Views
    996

    I'm the one who said that data tags are usually...

    I'm the one who said that data tags are usually incorrect and I'm the one who said SH and SC and a good thermometer with a PT chart is all ya need to charge a cap system, My company spends more time...
  5. Thread: Service manual

    by skpkey9
    Replies
    34
    Views
    996

    Hydra - what are you talking about not to have...

    Hydra - what are you talking about not to have sweat back to the compressor....I think ya need to rethink things abit...on that statement
  6. Thread: Service manual

    by skpkey9
    Replies
    34
    Views
    996

    There are ways around that if you know what you...

    There are ways around that if you know what you are doing and as I stated before that should only be talked about in the pro section, and also keep in mind we are also talking about the OPs cap...
  7. Thread: Service manual

    by skpkey9
    Replies
    34
    Views
    996

    Not against checking amps on a compressor, you...

    Not against checking amps on a compressor, you just dont charge to them. I check amps if I have an electrical problem with the compressor or seting up a CPR valve other then that its not necessary...
  8. Thread: Service manual

    by skpkey9
    Replies
    34
    Views
    996

    Neil- The only way I'm checking amp draw on a...

    Neil- The only way I'm checking amp draw on a compressor is if there are no taps and shell is blazing hot, so that I can see if the compressor is doing any work ( under a load ) or not other than...
  9. Thread: Service manual

    by skpkey9
    Replies
    34
    Views
    996

    All things considered it gets pretty aggravating...

    All things considered it gets pretty aggravating some of replies the OP has been given, cap tube system is charged by SH , I do use SC as a diagnostic tool on charging cap systems and using...
  10. Thread: Service manual

    by skpkey9
    Replies
    34
    Views
    996

    [QUOTE=K_Neil;15459571]The old ones sometimes...

    [QUOTE=K_Neil;15459571]The old ones sometimes need some magic. Get it cleaned up and watch pressures, amps, temps. Amps are a good indication if everything is clean charge to 1 amp lower than RLA and...
  11. Thread: Service manual

    by skpkey9
    Replies
    34
    Views
    996

    Coldtech is still around. The company that built...

    Coldtech is still around. The company that built that box was most likely Gemtech they wet out of business a few years ago.

    Personally I never go by data tags as most are incorrect, SH and SC....
  12. Replies
    16
    Views
    1,601

    They already make UVs for ice machines You're...

    They already make UVs for ice machines
    You're a I'll late on that one
  13. Replies
    4
    Views
    261

    Think nobody answered you cause you didn't give...

    Think nobody answered you cause you didn't give enough info....
    I'd check the auger and check production and after that check charge,

    That's the kind of info we need..

    Hope this helps...
  14. Thread: Polycold

    by skpkey9
    Replies
    2
    Views
    206

    http://www.brooks.com/support/technical-support/do...

    http://www.brooks.com/support/technical-support/documentation/cryochillers-cryocoolers/~/media/Files/Support/Documentation/Vacuum/WaterpumpChillers/Manual%20Cryocoolers/82512300.pdf


    I believe...
  15. Replies
    30
    Views
    2,154

    404 does have a phase out date can't remember...

    404 does have a phase out date can't remember when it is , but when I get to my office I will post it....
  16. Replies
    16
    Views
    986

    You haven't worked on your fair share yet or...

    You haven't worked on your fair share yet or you'd think differently, can't stand True boxes , but they keep me in business
  17. Replies
    18
    Views
    1,234

    Ya just can't beat the H-10 PM :.02: too...

    Ya just can't beat the H-10 PM :.02: too...
  18. Replies
    28
    Views
    1,868

    As everyone else has told ya call another...

    As everyone else has told ya call another company....

    That unit shipped 10/11/2002 all parts still available...

    It's truly sad how many shady contractors there are out there. :.02:
  19. Replies
    26
    Views
    1,786

    run a magnet along it afew times

    run a magnet along it afew times
  20. Replies
    26
    Views
    1,786

    If this is a heat pump I'd check to see if the...

    If this is a heat pump I'd check to see if the check valve is stuck.... and have him clean the coils evap and condenser.... that low of superheat with those pressures problem most likely at the air...
  21. Replies
    26
    Views
    1,786

    what are the SH and the SC numbers

    what are the SH and the SC numbers
  22. Replies
    8
    Views
    942

    Need more info.... model numbers

    Need more info.... model numbers
  23. Thread: Dripping Ducts

    by skpkey9
    Replies
    16
    Views
    2,055

    Very simple Store is under negative pressure... ...

    Very simple Store is under negative pressure... to confirm with all doors closed open one door a couple of inches while you are inside the building at the door that is being opened and if you feel...
  24. Replies
    20
    Views
    1,312

    To answer your question... Pump system down...

    To answer your question...

    Pump system down and allow condenser fan to run until exhausted air is the same as ambient, then break out your PT chart and check your high side pressure with unit...
  25. Replies
    6
    Views
    1,036

    We need more information... ie what are your...

    We need more information... ie what are your pressures and control settings and subcooling providing there is no receiver..... if compressor is close to evap I'd be more concerned with SH at the...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4