Keeping Up
Had A 2.5 Ton Condenser Installed With A 2 Ton Air Handler Cooled Great But The Condenser Finally Went 18 Years Old Got It Off A Job I Did. Put In A 2 Ton 13 Seer But Now System Has Trouble Keeping...
-
07-12-2008, 01:44 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
Been An Installer For 7 Years And A Tech Plus...
Been An Installer For 7 Years And A Tech Plus Installer For 3 Years . No One On Here Has Ever Changed Just A Condenser Out. The Company I Work For Has Been Around For 40 Years And Does This Sort Of...
-
07-12-2008, 12:38 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
I Donted Know How To Check For Bad Valves Sorry....
I Donted Know How To Check For Bad Valves Sorry. I Also Did Not Realize You Cant Ask Trobleshooting Q In This Part Of The Forum I Apologize To Everone I Will Apply For A Pro Membership. I See...
-
07-12-2008, 12:32 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
The Air Handler Was Brand New 2 Years Ago I Was...
The Air Handler Was Brand New 2 Years Ago I Was Just Using The Condenser Till It Died Did Not Have Money For New Condenser A Couple Years Back. Know The Whole Story Before You Make A Dumb Comment. I...
-
07-12-2008, 12:06 PM
- Replies
- 153
- Views
- 5,728
Stuck Contactor Or Low Voltage Wiring Touching...
Stuck Contactor Or Low Voltage Wiring Touching Each Other.or Bad Tstat.
-
07-11-2008, 11:15 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
if it is not the piston what would cause the...
if it is not the piston what would cause the valves to go age.
-
07-11-2008, 10:59 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
sorry maybe i misunderstood you.
sorry maybe i misunderstood you.
-
07-11-2008, 10:55 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
if it does not seat right i would assume ther...
if it does not seat right i would assume ther would be to much ref flow no high side back pressure and too much low side presure like i have because i am nor resticting the freon. and yes the...
-
07-11-2008, 10:48 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
yea i know i need to lighten up my own girlfrend ...
yea i know i need to lighten up my own girlfrend tells me that all the time . i mean i dont need to know the problem i am putting in the new condenser monday. but for my own benefit and future...
-
07-11-2008, 10:26 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
can somebody answer a q without talking down to...
can somebody answer a q without talking down to sombody no wonder i dont post a lot there are a lot of jerks on this site. i am not asking how to install somthing just a troubleshooting q
-
07-11-2008, 10:21 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
i was joking about the 85 percent i have run into...
i was joking about the 85 percent i have run into bad caps bad contactor coils bad compressors bad compressor fan motors . it was a joking lighten up i said that because i was wating for...
-
07-11-2008, 10:14 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
no furnace just an attic air handler
no furnace just an attic air handler
-
07-11-2008, 09:57 PM
Thread: am i missing something
by GREATONE- Replies
- 26
- Views
- 858
am i missing something
have a 2.5 ton carrier condenser has cooled for 2 summers real good. the other day i noticed the air has lost its bite. put my gauges on it high side it is low 150 or so low side is...
-
i want to do it on my own test on my home system ...
i want to do it on my own test on my home system for superheat i installed it last summer it runs fine but i want to learn the right way ...
-
wet bulb
how do you get or do wet bulb temp what does it mean
-
it is cold and condesing but that does not mean...
it is cold and condesing but that does not mean it is charged dead on probely close i want it running to 100 percet eff
-
superheat
i tried to do superheat on my home system today system is worked fine all summer i was just bored.i took outdoor dry bulb 80 - indoor wet bulb 71 where they interseck i get a superheat of 26 - 28 ....
-
psi
i just finished installing my own ac system. 2 1/2 ton. the room temp is 72 today outside it is 85 and humid. my gauges read 220 on high side and 64 psi on suction side does that sound about right. i...
-
03-22-2007, 06:33 PM
Thread: mismached indoor outdoor units
by GREATONE- Replies
- 2
- Views
- 270
mismached indoor outdoor units
i have a 2 ton airhandler i installed last year since that time my boss gave me a 2 1/2 ton condenser from a job it was a throw out . it works fine. my question is can i make it work with the smaller...
-
brazing
is it alright to braze with a mapp tank.or should it be oxg ace.by the way this will be 3/4 and 3/8 copper.i tried it earlier on a scrap and it seem to work.i been doing hvac for 8 years but i...
-
ive done mostly installs for 8 years...
ive done mostly installs for 8 years and some residental and light comm service for a year going to take a nate test when i get more ex. by the way iam asuming there is a...
-
spark
i have a lennox 80 plus furnace with itermitten spark ignition somtimes the pilot will not light . what happens is the exaust comes on the pressure switch closes the spark box clicks like it is...
Results 1 to 24 of 24