08-17-2005, 08:19 AM
Thread: gas smell only in the morning
by jeffcolledge- Replies
- 15
- Views
- 1,141
My suggestion: bring the person that smells the...
My suggestion: bring the person that smells the gas outside. Crack a union, slightly and have them take a whiff, make sure it's gas that he/she actually smells. It's a little unoethodox, but if...
-
09-22-2004, 08:08 AM
Thread: spark ignition systems
by jeffcolledge- Replies
- 17
- Views
- 1,408
theres is also a chance that the pilot is weak...
theres is also a chance that the pilot is weak and not reaching the burner when when the valve energizes.
-
09-15-2004, 07:17 PM
Thread: Help PLEASE with Delfield Reach-in
by jeffcolledge- Replies
- 13
- Views
- 1,178
Any licensed refrigeration mechanic can do it,...
Any licensed refrigeration mechanic can do it, they teach us how to wire a freezer in trade school. The only tricky part I found was trying to keep the "evap fan off when the door is open" feature. ...
-
09-15-2004, 05:13 PM
Thread: Help PLEASE with Delfield Reach-in
by jeffcolledge- Replies
- 13
- Views
- 1,178
Those microprocessors are expensive and...
Those microprocessors are expensive and cheap...if you know what I mean. They will work for about a year or so, then start doing the same thing. I've had the same problem in the past, where the...
-
09-07-2004, 05:13 PM
Thread: kolpak quick disconnects line set
by jeffcolledge- Replies
- 6
- Views
- 621
I'm not sure if it was a koldpak, but I got to...
I'm not sure if it was a koldpak, but I got to cut one out once on a Saturday night emergency service call once. It was leaking and tightening it only meant I'd be fixing it again. The freezer was...
-
09-02-2004, 06:53 AM
Thread: Carrier furnace DC motor.
by jeffcolledge- Replies
- 6
- Views
- 1,210
try the residential forum, you may have better...
try the residential forum, you may have better luck.
-
08-31-2004, 07:27 AM
Thread: flashing sight glass
by jeffcolledge- Replies
- 5
- Views
- 920
That was the only conclusion I could come up with...
That was the only conclusion I could come up with too. It's just strange that BOTH circuits are doing it. I'll pump one down, replace the drier, evacuate and test again. Thanks for the input guys.
-
08-30-2004, 08:13 PM
Thread: flashing sight glass
by jeffcolledge- Replies
- 5
- Views
- 920
The system is a 50 ton refer unit with r22. Each...
The system is a 50 ton refer unit with r22. Each circuit is independent with 25hp semis. Both have sight glasses that are flashing. Both have 15F subcooling. How is this possible? I took the...
-
08-25-2004, 07:48 AM
- Replies
- 30
- Views
- 2,755
Just a thought...Is the new motor a condenser fan...
Just a thought...Is the new motor a condenser fan motor? Sometimes they will have all the same data, but will overheat as they are an "air-over" motor. This meaning that they use the air drawn...
-
08-22-2004, 06:04 PM
Thread: R404 or R408?
by jeffcolledge- Replies
- 37
- Views
- 11,095
hey Dave.. I appreciate your insight on this...
hey Dave..
I appreciate your insight on this subject. No worries though, I never once took anything he said to be factual. You're obviously well trained in this trade and I think everyone who... -
08-21-2004, 09:33 PM
Thread: ice machine problem
by jeffcolledge- Replies
- 4
- Views
- 678
My GUESS is: the nickel is worn off of the evap...
My GUESS is: the nickel is worn off of the evap and the ice is sticking to it during harvest.
-
08-20-2004, 07:28 PM
Thread: R404 or R408?
by jeffcolledge- Replies
- 37
- Views
- 11,095
Thanks guys...and er ..uh "2 seasons employed"...
Thanks guys...and er ..uh "2 seasons employed" for your responses!
I installed the unit today and used 404, almost a full jug!
It is working great. I'm going to check on it tomorrow just to... -
08-19-2004, 07:43 PM
Thread: R404 or R408?
by jeffcolledge- Replies
- 37
- Views
- 11,095
Hey Lusker...thanks for the reply The compressor...
Hey Lusker...thanks for the reply
The compressor comes with POE oil in it already. The unit has all the bells and whistles for low ambient capacity control too. I was just curious what some guys... -
08-19-2004, 05:45 PM
Thread: R404 or R408?
by jeffcolledge- Replies
- 37
- Views
- 11,095
I'm installing a new air cooled 5hp outdoor...
I'm installing a new air cooled 5hp outdoor condensong unit with capacity control tomorrow. It was originally a water-cooled 3hp unit, that had R408 dropped into it about 4 years ago. The condenser...
-
08-11-2004, 11:10 PM
Thread: Model number help
by jeffcolledge- Replies
- 4
- Views
- 664
looks like a 5-ton armstrong, i think the 15 is...
looks like a 5-ton armstrong, i think the 15 is actually 150, indicating the heating capacity in btu's
-
08-11-2004, 09:09 PM
Thread: BC Wages
by jeffcolledge- Replies
- 2
- Views
- 655
I know we're not supposed to ask about...
I know we're not supposed to ask about wages...but I'm curious if the wages in BC are comparable to Ontario. Could someone please give me a link to a website, I'm having trouble finding the info. ...
-
08-03-2004, 07:56 PM
Thread: oil failure problem
by jeffcolledge- Replies
- 12
- Views
- 782
Ok, so you think after defrost, the system is...
Ok, so you think after defrost, the system is flooding liquid, washing out the oil and failing on oil pressure? That makes sense to me, except the high discharge temp. Could you explain that one?...
-
08-03-2004, 07:27 PM
Thread: oil failure problem
by jeffcolledge- Replies
- 12
- Views
- 782
They only run the blast in critical times, like...
They only run the blast in critical times, like this, it rarely runs. Sometimes when they are doing a lot of production and they are in and out of it, they will run it too. They have a temp....
-
08-03-2004, 06:39 PM
Thread: oil failure problem
by jeffcolledge- Replies
- 12
- Views
- 782
Well, he said they were both tripped all three...
Well, he said they were both tripped all three times and they were both tripped today. I got to believe it's an oil problem and not a compressor problem at this point. I'm thinking piping may be a...
-
08-03-2004, 06:10 PM
Thread: oil failure problem
by jeffcolledge- Replies
- 12
- Views
- 782
Ice... Thanks for the reply... Pumpdown lpc...
Ice...
Thanks for the reply...
Pumpdown lpc are working.
Contactors are good, oil failure is 240 volt, inseries with coil, compressor is 600volt
Watched both compressors for 3 hours, with a... -
08-03-2004, 05:11 PM
Thread: oil failure problem
by jeffcolledge- Replies
- 12
- Views
- 782
Two carlyle 06d compressors twinned together with...
Two carlyle 06d compressors twinned together with a common oil line between them. The application is a walk-in freezer maintaining below 0F using R507 & POE oil. Thermostat/defrost control is a...
-
07-29-2004, 10:39 PM
Thread: refrigerant stuck in receiver
by jeffcolledge- Replies
- 15
- Views
- 1,072
There are two 3000lb Maja units and one 3000lb...
There are two 3000lb Maja units and one 3000lb Howe I was told they were 25 hp, the model # are 06ey450-140. I'ts working great now with both of them working. Thanks for the input!
-
07-29-2004, 05:04 PM
Thread: Replacing Mr. Slim
by jeffcolledge- Replies
- 1
- Views
- 871
Why are you replacing it? I've pulled them out...
Why are you replacing it? I've pulled them out and repaired leaks, replaced motors and cleaned them before.
-
07-29-2004, 05:00 PM
Thread: froze up again!
by jeffcolledge- Replies
- 10
- Views
- 873
Wow R12, I think you covered all the bases! The...
Wow R12, I think you covered all the bases! The only thing I could add to that is...are you sure the time clock is working? Set it to the exact time next time you're there, and come back again at...
-
07-29-2004, 07:11 AM
Thread: refrigerant stuck in receiver
by jeffcolledge- Replies
- 15
- Views
- 1,072
Yeah, it makes 9000lbs/day!
Yeah, it makes 9000lbs/day!
Results 1 to 25 of 86