Search:

Type: Posts; User: mtnwrench

Page 1 of 15 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    1
    Views
    602

    Jace/FX60 One shot timer

    Trying to set time on timer portion of the relay from a button. Would like to be able to set minutes. When I use a numeric constant and link, it always goes to seconds.
    Is it possible to set just...
  2. Replies
    0
    Views
    971

    Trane 580/581 Visio stencil

    Anyone have one they would be willing to share?
  3. Replies
    11
    Views
    1,807

    problem solved and understandable. Thanks Doug

    problem solved and understandable. Thanks Doug
  4. Replies
    11
    Views
    1,807

    Still not a call back to me. Oh well..... Its the...

    Still not a call back to me. Oh well..... Its the plug end. Guess I will be doing a little soldering.
  5. Replies
    11
    Views
    1,807

    Digicool....awesome service. Not!

    Two month old clamp had the wires snap off right at the connector. Anyone have the link to the repairs on the clamp sensors as Digicool refuses to answer the damn phone?

    I love fixing two month...
  6. Replies
    21
    Views
    2,274

    Berg... what drugs are you smoking? Never once...

    Berg... what drugs are you smoking?

    Never once paid a yearly fee to keep my FX's running.

    My FX's can somehow manage to keep time all year long. Please show me a NAE that can do that.

    I have...
  7. Replies
    12
    Views
    1,624

    Digi 1600 or wait.....?

    Going to give digicool a try. Get the 1600 or wait for the AK?
  8. Replies
    15
    Views
    3,341

    I use one made by REFCO. Great little tool on...

    I use one made by REFCO. Great little tool on dead systems.
  9. Replies
    15
    Views
    8,002

    Sure... I can send you a copy. Wont work, you...

    Sure... I can send you a copy. Wont work, you will never get it licensed. Its licensed to the CD code and mine is already used. Need to get your own version from Trane.
  10. Replies
    0
    Views
    580

    York part number help???

    deleted
  11. Replies
    11
    Views
    2,012

    G5... Not even a contest.

    G5... Not even a contest.
  12. Replies
    9
    Views
    966

    Well.... I tried a day of the old way and it...

    Well.... I tried a day of the old way and it sucks. Got used to the Testo doing my SH and SC so a new 550 is now on the way.

    Cost of business?

    My tool bag bit the big one as well so... more...
  13. Replies
    9
    Views
    966

    Testo 523, get real....

    Have a two year old 523 that the pipe clamp (temp probe) ate the big one today and no longer works. Gee, I love my options... buy a new temp probe for 259.00 or a new 550 meter for 279.00.
    Bite me,...
  14. Replies
    13
    Views
    1,298

    Need Win 7 Pro- Run virtual XP machine for HVAC...

    Need Win 7 Pro-
    Run virtual XP machine for HVAC Pro
    NAE's run fine on Win 7 with IE 8 provided you play the Java Wheel Game.
    FX20,60 seem to hate IE8, get Firefox.

    You can load Mtools directly...
  15. Replies
    7
    Views
    807

    Undercontrol, I got you but these are make up...

    Undercontrol,

    I got you but these are make up air handlers that feed fan coil boxes. The make up airs didnt come with freeze stats installed for unit heat failure so they are using the logic to...
  16. Replies
    11
    Views
    2,300

    This thing isnt running on real low ambient...

    This thing isnt running on real low ambient temps. Starts at 50 degrees. The problem stays with circuit 2. Circuit one will start up and run normal.

    On the first start of the day, the compressor...
  17. Replies
    11
    Views
    2,300

    RTAA080, installed in 2000. No inverters on the...

    RTAA080, installed in 2000. No inverters on the fans,just staged.

    Problem stays with the same circuit, never on the other circuit. Makes me think not flow but will check superheats, subcools and...
  18. Replies
    11
    Views
    2,300

    RTAA- Low evap refr temp

    This problem started near the end of last fall but would never duplicate while there. On a cold start, I can get it to happen this spring.

    Circuit starts, runs normally for a few minutes and will...
  19. Replies
    7
    Views
    807

    Changed programming this morning. Works as it...

    Changed programming this morning. Works as it should now. Thanks jci guy.
  20. Replies
    7
    Views
    807

    Give that a try in the morning, thanks.

    Give that a try in the morning, thanks.
  21. Replies
    7
    Views
    807

    Where? We have a "x

    Where?

    We have a "x<y" block, going to a "and" block, going to a "timer" block ending up in a "latch". Out of the latch is connected to the shutdown command. Where do I change anything to...
  22. Replies
    7
    Views
    807

    NAE logic problem

    I inherited an NAE with some logic built onto the NAE for a couple of air handlers. The logic sends a true command to the shutdown of the air handlers if the DA-TE is too low. After the temps rise...
  23. Replies
    19
    Views
    2,837

    +1 With Lonspec they are simple. Without.......

    +1
    With Lonspec they are simple. Without.... good luck. Just dont think they are like the 7300 where you can enter configuration mode with the press of a few buttons. The problems we had were...
  24. Replies
    7
    Views
    1,022

    JAVA, JAVA, JAVA is correct, I get into all my...

    JAVA, JAVA, JAVA is correct, I get into all my NAE's and NCE's with no trouble. Not so much luck on FX20's. They seem to dislike IE8.
  25. Replies
    19
    Views
    2,837

    Have to disagree with you here. I think these...

    Have to disagree with you here. I think these things suck when compared to T7300. The only configuration changes you can make without Lonspec or a PDA is deg F/C and local or remote sensor. They come...
  26. Replies
    19
    Views
    2,837

    Just did a job with about a dozen of them. You...

    Just did a job with about a dozen of them. You will need Lonspec or Honeywell PDA to make configuration changes if necessary. Not too bad but nothing special.
  27. Replies
    4
    Views
    1,162

    Worked great. Thanks to all those that sent me...

    Worked great. Thanks to all those that sent me ways to do it.

    I was stuck in a vicious circle of trying to reset the latch trigger using the output of another latch, the same way I would do it on...
  28. Replies
    4
    Views
    1,162

    Trane TGP lead/lag...

    Anyone have an example they could screenshot or email me on lead/lag pumps in TGP. Getting my butt kicked trying to reset the latch trigger (error, circular loop).
  29. Replies
    3
    Views
    560

    Figured this out for those who might ever need...

    Figured this out for those who might ever need it....

    You have to bring the AI in as an AO, and map to AI. Options tab can only over ride an AO. What a pita... give me an AX over this anyday.
  30. Replies
    3
    Views
    560

    When I right click, I get- view, command and...

    When I right click, I get- view, command and extensions.

    When you drag a point onto the right panel, you see the heading at the top of the point such as hardware, trend, etc...

    Looking to add...
  31. Replies
    3
    Views
    560

    NAE Option's tab...

    How do I add an Options Tab to a point that is being controlled by a global data share?
  32. Replies
    1
    Views
    586

    Did a system restore to an earlier point before...

    Did a system restore to an earlier point before 2.1 and 1.2 works.
  33. Replies
    1
    Views
    586

    FX Workbench problems...

    I had FX Workbench 1.2. Upgraded to 2.1 about a month ago. Checked both that day and both worked fine.
    Today, neither Workbench will open. The computer they are loaded in has not been used or had...
  34. Replies
    24
    Views
    2,233

    I have never seen a Tracker panel that didnt come...

    I have never seen a Tracker panel that didnt come with the software in the packet. With that said, it only costs like 100.00. Just call Trane and order the damn software. You can waste that much...
  35. Thread: Wgx 9100

    by mtnwrench
    Replies
    6
    Views
    1,411

    HVAC Pro is for Johnson ASC devices such as AHU,...

    HVAC Pro is for Johnson ASC devices such as AHU, UNT, VAV, VMA...

    GX9100 is for DX9100 controller.
  36. Replies
    19
    Views
    1,607

    It has to be better than Chicago last year. Those...

    It has to be better than Chicago last year. Those were some cold days.
  37. Replies
    8
    Views
    2,480

    Went to Rover 7 wth the usb loncard. Runs fine on...

    Went to Rover 7 wth the usb loncard. Runs fine on Win 7. No problems yet...
  38. Replies
    9
    Views
    971

    If I remember right, there was a patch that you...

    If I remember right, there was a patch that you needed in order to make M3 fly correctly on XP. We have one system on a XP computer and no problems.

    And I say this as I have to go find a M3 cd to...
  39. Replies
    2
    Views
    1,434

    Now that I can live with. Thanks.

    Now that I can live with. Thanks.
  40. Replies
    13
    Views
    2,003

    Only two I know of right now are the UC800 for...

    Only two I know of right now are the UC800 for chillers and UC400 which is programmable with Tracer TU.
  41. Replies
    13
    Views
    2,003

    They are already out. Had the controllers months...

    They are already out. Had the controllers months ago, software just showed up.
  42. Replies
    19
    Views
    2,149

    Add me as well please.

    Add me as well please.
  43. Replies
    2
    Views
    1,434

    AX (FX-20,40,60) Boiler Graphic

    Anyone willing to share a better boiler graphic than the one that comes loaded on the FX series. Too embarassed to actually put that one on a screen the customer gets to see. The term "GAY" comes to...
  44. Replies
    3
    Views
    974

    Trane Varitrac to AX?

    Is it possible to pull in the Varitrac (CCP3) to an AX? I have pulled in other Trane LON systems but never tried Varitrac. We have three on a comm5 loop along with other controllers and a Tracker....
  45. Replies
    8
    Views
    2,480

    Win 7 and Trane Rover.....

    Anyone got this to fly yet? When running in XP mode, Windows does not see my PC card. Thinking I am going to have to get a USB-PC card adaptor unless you guys have some other suggestions.
  46. Replies
    9
    Views
    1,848

    A company called Yamas Controls originally did...

    A company called Yamas Controls originally did the job and did not leave a copy of Workplace Pro on the job. They actually told the owners they could not have it. This branch of Yamas is no longer...
  47. Replies
    9
    Views
    1,848

    Workplace Pro

    I have a R2 Jace that the building owners have installed two new Trane Intellipaks. I need to add the points off these units for monitoring purposes only. A little research has shown me I need...
  48. Replies
    0
    Views
    463

    Jace R2 Admin

    deleted
  49. Replies
    4
    Views
    628

    Thanks Phantom, I will give that a go tomorrow....

    Thanks Phantom, I will give that a go tomorrow. Thanks again.

    Guess it would help if one would actually read the help file, A= B+C+D..... Doh!
  50. Replies
    4
    Views
    628

    Tried that..... no work. My configs show that...

    Tried that..... no work. My configs show that value as being a "0" and the big "0" is what shows up on the NAE when I map that point.

    I think the correct term I am looking for is comfort setpoint....