  1. Replies
    24
    Views
    2,136

    The mitsubishis are 2.5, 2.5, and 3.0 tons the...

    The mitsubishis are 2.5, 2.5, and 3.0 tons the emer. backup really never runs so yea it still equals around 15 tons of cooling. The minisplits are "low ambient" capable but are not "0' deg." capable....
  2. Replies
    11
    Views
    2,221

    I don't see their heat exchangers or see an...

    I don't see their heat exchangers or see an explanation. I'd stick with air-air on a hrv and use water -air for heating. If you try to make these things do to much they end up not doing anything...
  3. Replies
    24
    Views
    2,136

    Central Oregon is not humid. but I really need a...

    Central Oregon is not humid. but I really need a reliable source before I can start giving averages. Basically when I was in residential we installed humidifiers and they run quite often to maintain...
  4. Replies
    24
    Views
    2,136

    economizer capabilities for server room

    The economizer is a little confusing. I am looking for any information to clarify the purpose and capabilities of these units. I am an Hvac tech from the residential installer upbringing but have...
  5. Sorry I was intending this thread to go to the...

    Sorry I was intending this thread to go to the commercial controls area

    Internala/c
  6. economizer capabilities in server room

    The economizer is a little confusing. I am looking for any information to clarify the purpose and capabilities of these units. I am an Hvac tech from the residential installer upbringing but have...
  7. Replies
    21
    Views
    1,813

    Exactly, I can do the job for a fraction of the...

    Exactly, I can do the job for a fraction of the price. I figured about $1,350 for all the 24v ARD dampers, Qty8 16" 90* elbows, the upsized transformer, and the control wires(18gauge).
    These...
  8. Replies
    21
    Views
    1,813

    Oh, the question. Has any body worked with 120v...

    Oh, the question. Has any body worked with 120v dampers? So far my suppliers shot me down. ("No such product") Are there any installers out there?:rolleyes:
  9. Replies
    32
    Views
    2,873

    Is the Goodman unit a 'RTU' or is it a split...

    Is the Goodman unit a 'RTU' or is it a split unit? Because maybe an economiser kit with 100% exhaust could be added if it was an 'RTU'. But I'm not sure if that is in the budget or even possible w/...
  10. Replies
    21
    Views
    1,813

    120v round dampers ?

    I'm perfectly happy with a 24v Honeywell ARD damper but some how an electrician got a say in my next project. Anyways, he is suggesting a 120v round damper instead of a 24v. So my orders are to see...
  11. Replies
    5
    Views
    778

    thanks for the replies, It'll be awhile before I...

    thanks for the replies, It'll be awhile before I can give you an adequate response.
  12. Replies
    5
    Views
    778

    Intellipak on 0% economizer 24/7

    The title is the problem. Does any one know what might be causing this? All other intellipaks are using the economizer at varying percentages. There are no active diagnostics. I realize this could...
  13. Replies
    11
    Views
    1,160

    A heat pump should run for at least 10 minutes...

    A heat pump should run for at least 10 minutes before it heats the house. that is just an estimate and open to oppinion but one thing is for sure is that your unit costs more to start and stop than...
  14. Are you sure it was a mouse or was it the last...

    Are you sure it was a mouse or was it the last home owner, sometimes I can't tell the difference.
  15. Replies
    11
    Views
    1,160

    What you are asking for is not usually one set...

    What you are asking for is not usually one set point. This usually depends on the humidity outside, wind chill factor, and the temperature in relation to both of these. OH and the accuracy of your...
  16. Replies
    4
    Views
    809

    Are you sure the noise is coming from the blower?...

    Are you sure the noise is coming from the blower? 73* is should not be a problem for these units. Maybe your outdoor unit is running in y2 while your indoor unit is running is y1 (stages of...
  17. Replies
    16
    Views
    2,193

    I told you that I'm am an HVAC tech. not an HVACR...

    I told you that I'm am an HVAC tech. not an HVACR tech YET. I am not too proud to call a "refer tech" out, but I have time to learn about these units if you guys do. so I am asking for your help. ...
  18. Replies
    16
    Views
    2,193

    The compressor nameplate did say 16 poe and the...

    The compressor nameplate did say 16 poe and the refrigerator nameplate said 17oz. So 16 or 17oz I'll try both if I decide to evacuate the system.
    The unit is likely to be just R-22 but I might...
  19. Replies
    16
    Views
    2,193

    compressor is hot, loud & short cycles

    This may seem elementary but here goes. I've got a reach-in refer that is holding at desired temp but it is really hot. After reaching the desired temp the pressure cut-out cycles the unit one to...
  20. Replies
    2
    Views
    485

    water conditioning in boilers?

    I am looking for optimal water condition and also poor condition so that I can adjust appropriatley. We have test kits and gallons of chemicals for the boiler water in the mechanical room but I have...
  21. Replies
    6
    Views
    848

    My unit is a 2 ton unit and it is under waranty...

    My unit is a 2 ton unit and it is under waranty because my company honored it as new. Matter of fact I already have a new compressor sitting in my garage waiting for me to put it in. But I noticed...
  22. Replies
    0
    Views
    422

    flue dust in pressure switch

    Pressure switch on two seperate boiler units are not satisfied with combustion air after I performed maintanance on burner assemblies. Could the exhaust flue dust that I stirred up clog internal...
  23. Replies
    6
    Views
    848

    Trane compressor Knocks

    My compressor is knocking and tripping the breaker on startup sometimes I was told that the Hermetic compressors somtimes get knocked off their springs. This is a new unit to me but it has been...
  24. Replies
    24
    Views
    4,079

    I'd suggest changing the lineset since your...

    I'd suggest changing the lineset since your quotes are for 410A refrigerant.
  25. Replies
    18
    Views
    1,671

    That boss is crook or an idiot.

    That boss is crook or an idiot.