    All is well thanks for the encouraging responses

    All is well thanks for the encouraging responses
  2. Replies
    9
    Views
    784

    Yea it was under warranty and they were in a big...

    Yea it was under warranty and they were in a big hurry to return it. Crane set it in the back of the truck and off it went. I pulled the lugs off but forgot the rest. I just hope I didn't damage the...
  3. Replies
    9
    Views
    784

    I hope I'm as lucky

    I hope I'm as lucky
  4. Replies
    9
    Views
    784

    Semi Hermetic Screw up

    I was wiring up a rebuilt Trane semi hermetic today and forgot to install the strips that tie lugs 4.5.6 together, (240V). The old ones were to be used on this one but got taken away with the old...
  5. Replies
    31
    Views
    3,305

    6 degrees in 2 1/2 hours is actually pretty good....

    6 degrees in 2 1/2 hours is actually pretty good. You just may not be able to maintain proper superheat till you get some heat out of the house.
  6. Replies
    22
    Views
    2,224

    Or switch to oil at 50 degrees with an outdoor...

    Or switch to oil at 50 degrees with an outdoor stat and no need for a defrost.
  7. Replies
    31
    Views
    3,305

    80# suction with a 72 line temp would be 24...

    80# suction with a 72 line temp would be 24 degree superheat. Your not that far off. Did you leave it running? might look better after the house cools off.
  8. Replies
    31
    Views
    3,305

    Did you check supply air temp at furnace or look...

    Did you check supply air temp at furnace or look at the stat? I'm with the guy who said you might be pulling attic air. If that's not it you might pull the bulb on the TXV and see if that changes...
  9. Replies
    6
    Views
    901

    I haven't had to change out a Trane compressor...

    I haven't had to change out a Trane compressor this year. That's some kind of miracle.
  10. Replies
    2
    Views
    923

    Thanks!! I took the test 11 yrs ago. I didn't...

    Thanks!! I took the test 11 yrs ago. I didn't have a clue who gave it to me. I tried ESCO first, typed in name and SS# and there it was.:D
  11. Replies
    2
    Views
    923

    Lost refrigerant card

    Anyone know how to get a refrigerant certification card replaced. I'm probably going to switch jobs and need to get it replaced.
  12. Replies
    24
    Views
    7,998

    Ok I just spent the better part of a day trying...

    Ok I just spent the better part of a day trying to braze in a new 10 ton Trane compressor. I used sil-flos and it leaked like crazy. But it looked nice. Then I gave both lines a shake and pulled both...