  3. Advice on easy to set up small BAS system

    There's a lot of programing going on here, definitely not a good project to get your feet wet on. A good place to start would be to sit down and generate a points list for each piece of equipment....
  4. Replies
    45
    Views
    2,946

    I've used the the navien header beside, not...

    I've used the the navien header beside, not really a fan of it plus it didn't really fit this application.
  5. Replies
    45
    Views
    2,946

    Yea here's the finished product. 470341

    Yea here's the finished product. 470341
  6. Replies
    45
    Views
    2,946

    Yes

    Yes
  7. Replies
    45
    Views
    2,946

    Navien Boiler install

    Navien Boiler install, not 100% done but pretty close. 468201
  8. Replies
    5
    Views
    324

    So your looking to bring mulitple FX-70s onto one...

    So your looking to bring mulitple FX-70s onto one central location via a FX-Server?
  9. Replies
    8
    Views
    452

    If the controllers themselves were going on and...

    If the controllers themselves were going on and offline I would say that's a common problem I've seen often, but the controllers are stable. It's the points themselves within the controllers at are...
  10. Replies
    8
    Views
    452

    My email is alliedtech12887@yahoo.com Thanks

    My email is alliedtech12887@yahoo.com
    Thanks
  11. Replies
    8
    Views
    452

    I also just checked my version of HVACPro and im...

    I also just checked my version of HVACPro and im running 8.08, where can i locate HVACpro 8.08b?
  12. Replies
    8
    Views
    452

    Okay thanks ill have to look it to that.

    Okay thanks ill have to look it to that.
  13. Replies
    8
    Views
    452

    Point Faults on JCI FX-60

    I have a building with a FX-60 and two trunks of N2 VMA's and DX's. There are about 50 devices per trunk. The issuse im having is that the points themselves keep going offline and into fault, FX60...
  14. Replies
    1
    Views
    190

    Honeywell Webbs 600 Login Issues

    Recently got a new account with a Honeywell Webb 600 and some Honeywell Spyder controls. The previous contractor changed the default admin password and would not release it to the custemor. Is there...
  15. Honeywell Spyder Programing and Service Tool question.

    Recently started servicing a new account with lon honeywell spyder. Just looking for availability on the service tool and programing software.
  16. Replies
    1
    Views
    211

    JCI FX-60 comm issues

    Received a call last week from a customer that was having issues connecting to their FX60 we installed 3 years ago. When I arrived on site I noticed there has no heart beat on the 60 and attempted to...
  17. Weil McLain LGB4 Steam Pressure Settings?

    The mechanical contractor I work for recently install a couple of Weil McLain LGB4 Steam Boilers all at different locations. I'm a little rusty when it comes to steam and couldn't find anything in...
  18. Should the max masters be lowered and the info...

    Should the max masters be lowered and the info frames be brought up since this is the only device on the mstp trunk?
  19. The controller info is Device Instance-0077000...

    The controller info is
    Device Instance-0077000
    Baudrate-38400
    MSTP Add-011
    Max Masters-127
    Max Info Frames- 020
  20. I'm using 22 AWG 3-wire twisted, shielded cable...

    I'm using 22 AWG 3-wire twisted, shielded cable and the baud rate is set for 38,400. What's the recommended eol resistor size 250ohms?
  21. Carel Controls - JCI FX-60 MSTP issue.

    I have a Inovent RTU with carel controls and I'm attempting to bring the RTU onto a fx-60 via mstp. I'm able to discover the RTU and bring it into the FX but I'm having communication issues and the...
  22. Replies
    13
    Views
    914

    The recent java 7 update 21 has been giving our...

    The recent java 7 update 21 has been giving our jace supervisory connection issues.
  23. Replies
    37
    Views
    1,618

    Thanks for your help, do you remember what you...

    Thanks for your help, do you remember what you did to resolve the issue with your particular job?
  24. Replies
    37
    Views
    1,618

    Yea that's the issue that I'm having, is there a...

    Yea that's the issue that I'm having, is there a fix for the issue such as a firmware upgrade or is it not that simple?
  25. Replies
    37
    Views
    1,618

    402121402131402141402151402161402171 I included...

    402121402131402141402151402161402171
    I included some screen shots from today while on site. I created a new network and tried bringing in my devices notice how the device id is the same as the mac...
Results 1 to 25 of 120
Page 1 of 5 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event