Search:

Type: Posts; User: Sicofthis

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    57
    Views
    2,113

    Does the txv match the tonnage for the unit?

    Does the txv match the tonnage for the unit?
  2. Thread: Mini splits

    by Sicofthis
    Replies
    29
    Views
    1,077

    Excellent breakdown from Sam. I'm sure he...

    Excellent breakdown from Sam.

    I'm sure he meant nylog blue not "nylon".

    Damn auto correct ;)
  3. Replies
    12
    Views
    673

    From what I understand, thermoelectric is very...

    From what I understand, thermoelectric is very inefficient.
  4. Replies
    12
    Views
    673

    Magnetic Refrigeration

    Still in the development stages, GE has made some large advancements in magnetic refrigeration by cascading the cycle.

    Looks interesting, no compressor, no refrigerant, and this is not...
  5. B1morelli Ask a pro section is for home owners...

    B1morelli

    Ask a pro section is for home owners next time use tech to tech res. If you get your post count up and go pro, we will be able to give more detailed help.

    Verify control voltage at...
  6. Replies
    20
    Views
    1,481

    Which article? Could you add a direct link.

    Which article? Could you add a direct link.
  7. I'd imagine most horror story's for any brand is...

    I'd imagine most horror story's for any brand is the installer's fault.

    Shame on your installer for lying to you about the warranty. My own sister in law missed out on a 10 year warranty due to...
  8. Replies
    5
    Views
    335

    A 10 minute run time in January. That's not a red...

    A 10 minute run time in January. That's not a red flag by its self. The humidity issues do potentially point to oversized for the current load.

    Do you have the fan set to "on" or "auto" ?
    ...
  9. Replies
    5
    Views
    470

    Wrong forum

    Wrong forum
  10. Heh, I've done that before. I use my hand kinda...

    Heh, I've done that before. I use my hand kinda like a coupling. Wash hand and blow through fist.
  11. I think he is concerned by the mutiple compressor...

    I think he is concerned by the mutiple compressor failures.
  12. Try a voltage reading at the terminals if...

    Try a voltage reading at the terminals if possible. Is anything else ran off the contactor?

    Get an amp reading on the ground wire also.
  13. Where did you take the voltage reading?

    Where did you take the voltage reading?
  14. Thread: hourly pay

    by Sicofthis
    Replies
    98
    Views
    4,824

    http://www.bls.gov/ooh/installation-maintenance-an...

    http://www.bls.gov/ooh/installation-maintenance-and-repair/heating-air-conditioning-and-refrigeration-mechanics-and-installers.htm
  15. Replies
    12
    Views
    561

    He would still have the wrong txv and most likely...

    He would still have the wrong txv and most likely the wrong suction line size.
  16. Replies
    26
    Views
    902

    You still need a tech to make repairs, if you...

    You still need a tech to make repairs, if you would like temperature control.
  17. Replies
    12
    Views
    561

    An oil separator but its not gonna work. ...

    An oil separator but its not gonna work.





    No, for Equalization the compressors will need a sump port with a line connecting them.
    The suctions would already be connected...
  18. Replies
    12
    Views
    561

    Which of the following are you wanting to use? ...

    Which of the following are you wanting to use?

    1) Two 5 ton condensers

    2) One 10 ton dual circuit condenser

    3) One 10 ton single circuit 2 stage condenser

    The suction line may be too...
  19. With the discharge capped off and so little space...

    With the discharge capped off and so little space for the compressed air to fill. I'm not surprised it bent the casing.
  20. Replies
    26
    Views
    902

    Could be an actuator (motorized valve). You need...

    Could be an actuator (motorized valve). You need to have a tech look at it.
  21. Replies
    13
    Views
    540

    I'm in Baton Rouge also, I'd say use the reheat...

    I'm in Baton Rouge also, I'd say use the reheat for room temp control.
  22. Replies
    4
    Views
    263

    There is gonna be a large amount of infiltration....

    There is gonna be a large amount of infiltration.

    :)
  23. Don't know, I've never put it on windings.

    Don't know, I've never put it on windings.
  24. Ive used mineral spirits to clean out semi-herms,...

    Ive used mineral spirits to clean out semi-herms, expecially when doing oil changes after a burn-out. I think I could dig up some old manuals that recommend it. It cleans good and evaporates easily....
  25. Replies
    43
    Views
    1,733

    Four years apprentiship program? I'm not familiar...

    Four years apprentiship program? I'm not familiar with that.


    Working hard and changing company's when you're worth more than you employer will pay you. You may get lucky but, most employers...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event