05-10-2013, 08:19 AM
Thread: Water Furnace vs. GeoComfort?
by Bergy- Replies
- 10
- Views
- 569
Not on the coast, livin' in the heartland of...
Not on the coast, livin' in the heartland of Iowa.
Bergy -
04-27-2013, 09:23 AM
Thread: Water Furnace vs. GeoComfort?
by Bergy- Replies
- 10
- Views
- 569
The biggest difference in the units is the air...
The biggest difference in the units is the air coil. Water Furnace uses an E-coated coil that has, industry wide, issues with formicary corrosion. (Pitting of the copper causing refrigerant leaks to...
-
03-22-2013, 08:27 AM
Thread: out of my "comfort zone"
by Bergy- Replies
- 4
- Views
- 727
Leave your gauge set in the truck. Always do a...
Leave your gauge set in the truck. Always do a Heat of Extraction/Rejection first. If those numbers indicate a problem then, and only then, hook up the gauge set.
Bergy -
01-25-2013, 08:32 AM
- Replies
- 11
- Views
- 1,426
What's the flow rate on the LOAD side? You need...
What's the flow rate on the LOAD side? You need to know if the load side is absorbing the proper amount of Btu's.
Bergy -
01-04-2013, 09:51 AM
Thread: Waterfurnace premier 2 tripping!
by Bergy- Replies
- 4
- Views
- 747
You need a qualified service tech. Messing with...
You need a qualified service tech. Messing with high voltage can be deadly!
-
09-26-2012, 08:12 AM
Thread: Tax refund question
by Bergy- Replies
- 11
- Views
- 2,178
It is not a refund, it's a tax credit. You must...
It is not a refund, it's a tax credit. You must have a tax liability in order to get the 30% credit.
Bergy -
08-30-2012, 01:10 PM
Thread: Calling all pro members
by Bergy- Replies
- 16
- Views
- 2,514
Loopers ARE in a partnership with HVAC...
Loopers ARE in a partnership with HVAC contractors. We do all the design work with our computer programs but that cannot tell us what is actually out at the job site. Our loopers know the geology of...
-
08-25-2012, 10:25 AM
- Replies
- 5
- Views
- 1,060
Two systems on a single loop should have their...
Two systems on a single loop should have their own pumps. They should be piped as shown, this will insure proper flow through the units without short cucling between them.
Bergy303341 -
06-08-2012, 10:31 PM
- Replies
- 36
- Views
- 3,651
Make sure a 4 ton unit isn't oversized for your...
Make sure a 4 ton unit isn't oversized for your cooling loads. If you wind up with too much cooling you may find your home feels like a cave.
Bergy -
03-22-2012, 02:19 PM
Thread: Geothermal Loop Pressure Gauge
by Bergy- Replies
- 2
- Views
- 1,269
www.Geo-flow.com Look for their Geo-Gooser ...
www.Geo-flow.com Look for their Geo-Gooser
Bergy -
02-29-2012, 11:18 PM
Thread: Bad Water Pressure - Open Loop Geo Thermal
by Bergy- Replies
- 14
- Views
- 3,080
Called my Geo guy who is kind of a "under the...
Called my Geo guy who is kind of a "under the table" operator
Perhaps it's time to call in an "above the table" operator.
Bergy -
11-16-2011, 04:23 PM
- Replies
- 13
- Views
- 6,227
Enertech manufactures Hydron Module, GeoComfort...
Enertech manufactures Hydron Module, GeoComfort and Tetco heat pumps. Paradise was a short lived WF private lable for Enertech.
Bergy -
11-06-2011, 08:40 AM
Thread: Determinant of Number of Closed Loops
by Bergy- Replies
- 15
- Views
- 1,773
All of the better Honeywell stats carry a five...
All of the better Honeywell stats carry a five year warranty.
Bergy -
10-13-2011, 05:42 PM
Thread: Geo Comfort by Enertech- Good,Bad or Ugly
by Bergy- Replies
- 7
- Views
- 1,527
We have been with Enertech for eleven years now....
We have been with Enertech for eleven years now. First they were a Climate Master rep but switched to Water Furnace and had them manufacture a GeoComfort brand for them. Enertech was not satisfied...
-
10-12-2011, 08:21 AM
Thread: comparing bids / comparing contractors
by Bergy- Replies
- 15
- Views
- 2,420
Be careful with unsupported claims... I have been...
Be careful with unsupported claims... I have been involved with WaterFurnace and Enertech, makers of Hydron Module, GeoComfort and Tetco. The service we get from Enertech is second to none! Can I...
-
07-19-2011, 05:34 PM
Thread: Homebrew ground source hydronic cooling
by Bergy- Replies
- 12
- Views
- 1,602
The 3/8 inch is NOT your bottleneck... The eight...
The 3/8 inch is NOT your bottleneck... The eight 1/8 inch lines are!!
Bergy -
07-10-2011, 10:10 AM
Thread: Homebrew ground source hydronic cooling
by Bergy- Replies
- 12
- Views
- 1,602
That coil will not work. It is designed for...
That coil will not work. It is designed for refrigerant, not water. You will have to find a water coil for your experiment.
Bergy -
06-29-2011, 03:32 PM
Thread: waterfurnce or Hydron module?
by Bergy- Replies
- 5
- Views
- 2,304
While we are a GeoComfort/Hydron Module dealer...
While we are a GeoComfort/Hydron Module dealer and a BIT biased.... Your decision should come down to who the best contractor is.
Bergy -
06-25-2011, 10:19 AM
Thread: Help! No cold air!
by Bergy- Replies
- 9
- Views
- 2,149
You DO NOT attach a gauge set to a Geo unless the...
You DO NOT attach a gauge set to a Geo unless the heat of rejection/extraction indicates it should be done.
Bergy -
06-01-2011, 10:24 PM
Thread: Maintenance of a GeoThermal pump
by Bergy- Replies
- 5
- Views
- 1,899
A Professional's list...
At start-up your contractor should have recorded the following...
Second stage cooling, or heating, with Desuperheater turned OFF.
Loop Side... Pressure In minus Pressure Out = Delta P
... -
05-22-2011, 04:35 PM
Thread: ClimateMaster Genesis Thermistor?
by Bergy- Replies
- 6
- Views
- 2,466
It sounds like a control board. Bergy
It sounds like a control board.
Bergy -
Go back to the GeoComfort unit. Whatever you...
Go back to the GeoComfort unit. Whatever you decide make sure the unit is energy star rated to qualify for the 30% tax credit.
Bergy -
03-05-2011, 07:27 PM
Thread: BARD Water Source Heat Pump StartUp Problem
by Bergy- Replies
- 8
- Views
- 2,263
High Voltage
Have you tried turning off, and back on, the heat pumps breaker?
Bergy -
02-22-2011, 09:51 PM
Thread: Low water temp
by Bergy- Replies
- 9
- Views
- 1,231
What type of antifreeze do you have in your loop?...
What type of antifreeze do you have in your loop? If it's Glycol, make sure it is mixed to a 25% level. I'm not sure what levels are needed for Methanol.
Bergy -
02-21-2011, 06:11 PM
Thread: My new Geothermal System
by Bergy- Replies
- 875
- Views
- 81,369
"Superheat, incoming air, and EWT. All play their...
"Superheat, incoming air, and EWT. All play their part in determining what the freon charges should be, and if you want them check you should have it done by someone who knows geo, not just a HVAC...