  1. Thread: Oil Burner

    by grendil
    Replies
    3
    Views
    397

    Oil Burner

    My Oil Boiler sounds like a Train..

    It was cleaned and testo put on it. I know I have cold water returning, so I put a little bypass pump.


    Don't do oil service..

    Ideas??
  2. Thread: York YCAG

    by grendil
    Replies
    0
    Views
    778

    York YCAG

    Anyone have a manual for an older Air Cooled Recip Chiller? Having some loading issues, The in house personel tried to change out an output board and the proble stiil exist. They thinks its the main...
  3. Replies
    45
    Views
    3,202

    Yes Yes..

    Yes Yes..
  4. Thread: CTV

    by grendil
    Replies
    13
    Views
    977

    No Donuts. Its got to be Muffins.. But he owes on...

    No Donuts. Its got to be Muffins.. But he owes on this one, we went through the program together so I make sure he is at all our start ups.
  5. Thread: CTV

    by grendil
    Replies
    13
    Views
    977

    Boys, Chill It will be a Factory Start up. We...

    Boys, Chill It will be a Factory Start up. We happen to work well with the Manu's. We get them real close and the boys have some easy Factory start up. In our area if you are a 537 UA Guy you are...
  6. Thread: CTV

    by grendil
    Replies
    13
    Views
    977

    Yes pressure was fine when it arrived. Econo was...

    Yes pressure was fine when it arrived. Econo was taken down and Rupture guard installed. Chiller pulled down well 308 Mi in 12 hrs. Just less than 500 Mi on Vac test, 308 ~ 774 Microns/ 12 hrs. Did...
  7. Thread: CTV

    by grendil
    Replies
    13
    Views
    977

    Yes, Oil in he Chiller. I do have to fill and...

    Yes, Oil in he Chiller. I do have to fill and vent Cond and Evap water circuit. I was pondering waiting to get the refrig in. Thoughts?
  8. Thread: CTV

    by grendil
    Replies
    13
    Views
    977

    CTV

    New Chiller, Pulled down to 308 Microns in about 12 Hrs. The vacuum rose to 774 Microns in 12 Hours, less than the 500 rise. Trane will be in on Monday. Should I let it stand or keep a V pump on it?
  9. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    what is tracer tu? How can i get that? on...

    what is tracer tu? How can i get that?

    on another note how do you like Dick Jaron?
  10. Thread: CVHF

    by grendil
    Replies
    3
    Views
    416

    Thanks, We had a start up of a new chiller last...

    Thanks, We had a start up of a new chiller last year and the Trane Tech had said this and was going to give it to me but my laptop was old and me the user. Not very good with all this comp stuff. I...
  11. Thread: CVHF

    by grendil
    Replies
    3
    Views
    416

    CVHF

    I heard the new Trane Chillers need software to access programing and identifying transducers ect. Is that true?

    Thnks
  12. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    Gents: The Dental Floss worked real well. I need...

    Gents:
    The Dental Floss worked real well. I need to get some pressure on the chiller in the am to see if all is tight.

    I heard the new CVHF you need software to access temp trans and dry start...
  13. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    Yes New Chiller.

    Yes New Chiller.
  14. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    thanks i hope they are better than the rubber

    thanks i hope they are better than the rubber
  15. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    jar66@comcast.net thankks

    jar66@comcast.net thankks
  16. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    silicone bead bolt holes?

    silicone bead bolt holes?
  17. Thread: GLYCOL FEDEER

    by grendil
    Replies
    11
    Views
    1,018

    lol

    lol
  18. Replies
    58
    Views
    9,191

    I have seen these talked about for sometime. I...

    I have seen these talked about for sometime. I have been cautious on using them based on what I have heard.

    I'm looking for retrofit applications. Can anyone give me some retrofits that I can...
  19. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    I removed the Econo today had some riiging stuff...

    I removed the Econo today had some riiging stuff but not much when I get to the chiller plant. First time seeing the new gaskets on the econo evap/Cond, anyy suggestions on how to hold in place?...
  20. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    LOL That he does.. The ticket is the only reason...

    LOL That he does.. The ticket is the only reason I keep DTV.. We shall see ya in the opener..
  21. Replies
    5
    Views
    1,049

    yeah i did notice that after the fact..

    yeah i did notice that after the fact..
  22. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    Jimbo: Thanks but I have to say sorry you have...

    Jimbo: Thanks but I have to say sorry you have T.O.. LOL
  23. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    Small 450 I beleive.

    Small 450 I beleive.
  24. Thread: CVHF

    by grendil
    Replies
    40
    Views
    2,512

    Brand spanking new. thanks

    Brand spanking new.

    thanks
  25. Replies
    5
    Views
    1,049

    Whos abs? You are definately carring over to your...

    Whos abs? You are definately carring over to your Refrig water. Are you losing Tempature? what is your issue? Not making temp?