Search:

Type: Posts; User: david222

Search: Search took 0.00 seconds.

  1. Replies
    24
    Views
    4,518

    Does anyone have the 8.08b patch. I contacted my...

    Does anyone have the 8.08b patch. I contacted my JCI rep. He was lost!!!
  2. Replies
    2
    Views
    309

    I have taken the FEC, extended architecture and...

    I have taken the FEC, extended architecture and the graphics classes. I got a lot out of each one, but it is best to have a little experience in the class you are taking. The instructors will not...
  3. Replies
    0
    Views
    189

    Controller Riser Diagram

    Did a search for this topic and nothing showed up. I am trying to get all of my controllers drawn up in cad. Does anyone have any examples that I could use? "Riser Diagram"?
    Thanks
    David
  4. Replies
    2
    Views
    206

    Thanks, I had looked everywhere? but there. ...

    Thanks,
    I had looked everywhere? but there.

    Thanks again
    David
  5. Replies
    2
    Views
    206

    JCI Unitary controller

    First- can you program to rotate pumps(lead/Lag) with Unitary controller?

    Second - If so does anyone have an example?

    Thanks
  6. Replies
    1
    Views
    226

    Sourcing / DMM meter combo

    Does anyone know of a calibration meter that will source 4-20ma , 0-10volts and is also a DMM. Just trying to save money by buying one meter.

    Thanks
  7. Replies
    2
    Views
    606

    JCI CCT programming/training

    I have just opened up the CCT software and quickly decided to look for help. I have been programing DX9100 and using HVACPRO. But this CCT likes foreign no ladder logic etc. Can someone suggest some...
  8. Replies
    6
    Views
    2,133

    NECC in phili Pa (neccdelivers.com) has a cd with...

    NECC in phili Pa (neccdelivers.com) has a cd with the all of the software necessary. Ask for Auggie I deal with him there.
  9. Replies
    7
    Views
    1,136

    Thanks South central Va. NC state line

    Thanks

    South central Va. NC state line
  10. Replies
    7
    Views
    1,136

    Applied for Commercial service tech in danville,...

    Applied for Commercial service tech in danville, va
  11. Replies
    7
    Views
    1,136

    Freezemiser I did not realize they are in PA....

    Freezemiser
    I did not realize they are in PA. Thanks for answering. What do you do for CW?
    I have applied for a position with them and just trying to find out how they are to work for. Any input?
    ...
  12. Replies
    7
    Views
    1,136

    Colonial Webb Contractor

    I am trying to find out some info. on Colonial Webb Mechanical. They are located in the east. Is any one familiar with them from an employee perspective?
  13. Replies
    2
    Views
    498

    Thanks simux I went over the literature enclosed...

    Thanks simux
    I went over the literature enclosed with the pxp was not much help?
  14. Replies
    2
    Views
    498

    JC PXP setup question

    Does anyone have a simple step by step guide on how to set up a JC pxp?
    The pxp is tied to a DX9100. I have put the key in the 9100 an have figured out how to run the setting up to 100% and down to...
  15. Replies
    1
    Views
    918

    Johnson Metasys Training

    Looking for some advice/suggestions on getting traing on metasys.

    Thanks
    David
  16. Replies
    25
    Views
    1,840

    New condensing unit has no reciever and it is a...

    New condensing unit has no reciever and it is a cap tube. I started out with 12oz suction ran almost in a vacum. I have no superheat chart for this unit with 134. I thought suction should be around...
  17. Replies
    25
    Views
    1,840

    Thanks for all the suggestions. Got it running...

    Thanks for all the suggestions. Got it running seems ok 25# suction(maybe little high?), 140#head. Maintaining about 37* Only thing that supprised me called for 12oz when it was an R12 machine. Took...
  18. Replies
    25
    Views
    1,840

    model is Rht 1-32 wut s#34195. I have a new 134a...

    model is Rht 1-32 wut s#34195. I have a new 134a condensing unit i am installing.
    Thanks in advance
  19. Replies
    25
    Views
    1,840

    Converting to 134a

    I am converting a Traulsen commercial reach-in upright refrigerator (r12) cap tube metering, to 134a. Wondering how to charge? superheat?, weight? No superheat chart? Do not know how much r12 it...
Results 1 to 19 of 19