  1. Replies
    12
    Views
    365

    Looks to be 1962 ...

    Looks to be 1962



    http://www.buildingcenter.org/system/files/userfiles/images/BRYANT%20Serial%20Number%20Style%205.jpg
  2. Replies
    12
    Views
    410

    Check with samsung. I know that fujitsu sells...

    Check with samsung. I know that fujitsu sells high humidity insulation kits for their cassette.
  3. Replies
    16
    Views
    984

    As others have stated, snubber capasitors.

    As others have stated, snubber capasitors.
  4. Replies
    57
    Views
    2,449

    Did you verify the condenser fan motor was...

    Did you verify the condenser fan motor was spinning correct rotation? A faulty capasitor can cause it to spin in reverse. Or is it just recycling hot air thru it since you said it had alot of...
  5. Replies
    53
    Views
    1,880

    Dad, since the OP has now apologized can we get...

    Dad, since the OP has now apologized can we get this thread closed. No need for others to pile on...
  6. Replies
    11
    Views
    555

    Actually you were correct with your...

    Actually you were correct with your first(Shorted) post. I have a diagram but can't seem to upload it. Looks as if you have it handled though.
  7. Replies
    30
    Views
    1,502

    my guess is that there is a motorized fire damper...

    my guess is that there is a motorized fire damper in each supply drop in that combo plenum. They would all be daisy chained together, spring return closed with loss of power to them. Another reason...
  8. Replies
    43
    Views
    1,282

    I am glad this was finally mentioned!!! Good call...

    I am glad this was finally mentioned!!! Good call PHM. Also something to add, not knowing how much oil has been added over time I would assume that the refrigerant is "oil Saturated" not enabeling...
  9. Replies
    14
    Views
    562

    Need more info, Model# are these ducted...

    Need more info, Model# are these ducted systems,downflow,top plenum discharge?. They come with adjustable sheaves from the factory.
  10. Replies
    33
    Views
    1,093

    I also remember using R11 to flush out DX piping...

    I also remember using R11 to flush out DX piping on larger system installs.
  11. Just to use as a reference, The trane voyager...

    Just to use as a reference, The trane voyager uses the same blower wheel from 17-25 ton units. Not the same fan rpm as your system(still need to provide M&S numbers...)
  12. Replies
    8
    Views
    700

    If the compressor was insulated and the mud and...

    If the compressor was insulated and the mud and moisture rot makes me think that thing sat under water at some point in it's life.
  13. X2 Here.

    X2 Here.
  14. Replies
    5
    Views
    1,423

    Good thing is that it looks like there is enough...

    Good thing is that it looks like there is enough room to raise that thing and build a return platform. Definitely falls under
    hack category...
  15. Replies
    4
    Views
    286

    No schematic on one of the panels? Are you a...

    No schematic on one of the panels? Are you a tech.? Don't want to come across as an ass but this is 101 stuff. The transformer label should tell you what those leads are(primary,secondary). We can't...
  16. Replies
    17
    Views
    826

    My mistake...Foot in mouth syndrome:whistle:

    My mistake...Foot in mouth syndrome:whistle:
  17. Replies
    17
    Views
    826

    Have you verified your run cap is good? Could be...

    Have you verified your run cap is good? Could be causing compressor motor to labor more.
  18. Replies
    5
    Views
    448

    Give this a try 491821

    Give this a try

    491821
  19. Thread: Retired

    by PortaChill
    Replies
    6
    Views
    590

    When i was cutting my teeth(mid 80's). If we came...

    When i was cutting my teeth(mid 80's). If we came across a R500 Carrier they had us size down the TXV
    2-3 tons smaller and then charge with R22.
  20. Here is some PSIO info I had. 491061

    Here is some PSIO info I had.
    491061
  21. Replies
    15
    Views
    784

    Got a chuckle out of this one...

    Got a chuckle out of this one...
  22. If it has served its purpose,maybe would be best...

    If it has served its purpose,maybe would be best to cut it out and straight pipe it. If you feel you need it in the system
    then the 56% route would be best. If you do replace it,at least all the...
  23. Replies
    15
    Views
    549

    Is there any space between the condo units where...

    Is there any space between the condo units where you could run square or round duct? Have it enclosed with a
    stucco or sided soffet wall. Size your exhaust fans to be able to either draw or...
  24. Replies
    27
    Views
    1,166

    dlu, What you are are claiming as the "smudgy...

    dlu, What you are are claiming as the "smudgy oil" is probably soap bubble leak detector residue. It will make that carbon from the poor brazing job turn into a goo type mess.
  25. Replies
    94
    Views
    3,009

    well he should have at least color taped the...

    well he should have at least color taped the white wire... at least for the simple minded folk.:whistle: